Search results for: semen parameters
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 8568

Search results for: semen parameters

8508 Parameters Estimation of Multidimensional Possibility Distributions

Authors: Sergey Sorokin, Irina Sorokina, Alexander Yazenin

Abstract:

We present a solution to the Maxmin u/E parameters estimation problem of possibility distributions in m-dimensional case. Our method is based on geometrical approach, where minimal area enclosing ellipsoid is constructed around the sample. Also we demonstrate that one can improve results of well-known algorithms in fuzzy model identification task using Maxmin u/E parameters estimation.

Keywords: possibility distribution, parameters estimation, Maxmin u\E estimator, fuzzy model identification

Procedia PDF Downloads 436
8507 Analysis of Exponential Nonuniform Transmission Line Parameters

Authors: Mounir Belattar

Abstract:

In this paper the Analysis of voltage waves that propagate along a lossless exponential nonuniform line is presented. For this analysis the parameters of this line are assumed to be varying function of the distance x along the line from the source end. The approach is based on the tow-port networks cascading presentation to derive the ABDC parameters of transmission using Picard-Carson Method which is a powerful method in getting a power series solution for distributed network because it is easy to calculate poles and zeros and solves differential equations such as telegrapher equations by an iterative sequence. So the impedance, admittance voltage and current along the line are expanded as a Taylor series in x/l where l is the total length of the line to obtain at the end, the main transmission line parameters such as voltage response and transmission and reflexion coefficients represented by scattering parameters in frequency domain.

Keywords: ABCD parameters, characteristic impedance exponential nonuniform transmission line, Picard-Carson's method, S parameters, Taylor's series

Procedia PDF Downloads 409
8506 Seismic Response Mitigation of Structures Using Base Isolation System Considering Uncertain Parameters

Authors: Rama Debbarma

Abstract:

The present study deals with the performance of Linear base isolation system to mitigate seismic response of structures characterized by random system parameters. This involves optimization of the tuning ratio and damping properties of the base isolation system considering uncertain system parameters. However, the efficiency of base isolator may reduce if it is not tuned to the vibrating mode it is designed to suppress due to unavoidable presence of system parameters uncertainty. With the aid of matrix perturbation theory and first order Taylor series expansion, the total probability concept is used to evaluate the unconditional response of the primary structures considering random system parameters. For this, the conditional second order information of the response quantities are obtained in random vibration framework using state space formulation. Subsequently, the maximum unconditional root mean square displacement of the primary structures is used as the objective function to obtain optimum damping parameters Numerical study is performed to elucidate the effect of parameters uncertainties on the optimization of parameters of linear base isolator and system performance.

Keywords: linear base isolator, earthquake, optimization, uncertain parameters

Procedia PDF Downloads 397
8505 Experimental Determination of Aluminum 7075-T6 Parameters Using Stabilized Cycle Tests to Predict Thermal Ratcheting

Authors: Armin Rahmatfam, Mohammad Zehsaz, Farid Vakili Tahami, Nasser Ghassembaglou

Abstract:

In this paper the thermal ratcheting, kinematic hardening parameters C, γ, isotropic hardening parameters and also k, b, Q combined isotropic/kinematic hardening parameters have been obtained experimentally from the monotonic, strain controlled cyclic tests at room and elevated temperatures of 20°C, 100°C, and 400°C. These parameters are used in nonlinear combined isotropic/kinematic hardening model to predict better description of the loading and reloading cycles in the cyclic indentation as well as thermal ratcheting. For this purpose, three groups of specimens made of Aluminum 7075-T6 have been investigated. After each test and using stable hysteretic cycles, material parameters have been obtained for using in combined nonlinear isotropic/kinematic hardening models. Also the methodology of obtaining the correct kinematic/isotropic hardening parameters is presented.

Keywords: combined hardening model, kinematic hardening, isotropic hardening, cyclic tests

Procedia PDF Downloads 443
8504 An Experimental Analysis of Squeeze Casting Parameters for 2017 a Wrought Al Alloy

Authors: Mohamed Ben Amar, Najib Souissi, Chedly Bradai

Abstract:

A Taguchi design investigation has been made into the relationship between the ductility and process variables in a squeeze cast 2017A wrought aluminium alloy. The considered process parameters were: squeeze pressure, melt temperature and die preheating temperature. An orthogonal array (OA), main effect, signal-to-noise (S/N) ratio, and the analysis of variance (ANOVA) are employed to analyze the effect of casting parameters. The results have shown that the selected parameters significantly affect the ductility of 2017A wrought Al alloy castings. Optimal squeeze cast process parameters were provided to illustrate the proposed approach and the results were proven to be trustworthy through practical experiments.

Keywords: Taguchi method, squeeze casting, process parameters, ductility, microstructure

Procedia PDF Downloads 362
8503 Cissampelos capensis Rhizome Extract Induces Intracellular ROS Production, Capacitation, and DNA Fragmentation in Human Spermatozoa

Authors: S. Shalaweh, P. Bouic, F. Weitz, R. Henkel

Abstract:

More than 3000 plants of notable phyto-therapeutic value grow in South Africa; these include Cissampelos capensis, commonly known in Afrikaans as dawidjie or dawidjiewortel. C. capensis is the most significant and popular medicinal plant used by the Khoisan as well as other rural groups in the Western region of South Africa. Its rhizomes are traditionally used to treat male fertility problems. Yet, no studies have investigated the effects of this plant or its extracts on human spermatozoa. Therefore, this study aimed at investigating the effects of C. capensis rhizome extract (CRE) fractions on ejaculated human spermatozoa in vitro. Spermatozoa from a total of 77 semen samples were washed with human tubular fluid medium supplemented with bovine serum albumin (HTF-BSA) and incubated for 2 hourswith 20 µg/ml progesterone (P4) followed by incubation with different concentrations (0, 0.05, 0.5, 5, 50, 200 µg/ml) of fractionated CRE (F1=0% MeOH, F2=30% MeOH, F3=60% MeOH and F4=100% MeOH) for 1.5 hours at 37°C. A sample without addition of CRE fractions served as control. Samples were analyzed for sperm motility, reactive oxygen species (ROS), DNA-fragmentation, acrosome reaction and capacitation. Results showed that F1 resulted in significantly higher values for ROS, capacitation and hyper-activation compared to F2, F3, and F4 with P4-stimulated samples generally having higher values. No significant effect was found for the other parameters. In conclusion, alkaloids present in F1 of CRE appear to have triggered sperm intrinsic ROS production leading to sperm capacitation and acrosome reaction induced by P4.

Keywords: capacitaion, acrosome reaction, DNA fragmentation, ROS

Procedia PDF Downloads 271
8502 Number of Necessary Parameters for Parametrization of Stabilizing Controllers for two times two RHinf Systems

Authors: Kazuyoshi Mori

Abstract:

In this paper, we consider the number of parameters for the parametrization of stabilizing controllers for RHinf systems with size 2 × 2. Fortunately, any plant of this model can admit doubly coprime factorization. Thus we can use the Youla parameterization to parametrize the stabilizing contollers . However, Youla parameterization does not give itself the minimal number of parameters. This paper shows that the minimal number of parameters is four. As a result, we show that the Youla parametrization naturally gives the parameterization of stabilizing controllers with minimal numbers.

Keywords: RHinfo, parameterization, number of parameters, multi-input, multi-output systems

Procedia PDF Downloads 386
8501 Intelligent Production Machine

Authors: A. Şahinoğlu, R. Gürbüz, A. Güllü, M. Karhan

Abstract:

This study in production machines, it is aimed that machine will automatically perceive cutting data and alter cutting parameters. The two most important parameters have to be checked in machine control unit are progress feed rate and speeds. These parameters are aimed to be controlled by sounds of machine. Optimum sound’s features introduced to computer. During process, real time data is received and converted by Matlab software. Data is converted into numerical values. According to them progress and speeds decreases/increases at a certain rate and thus optimum sound is acquired. Cutting process is made in respect of optimum cutting parameters. During chip remove progress, features of cutting tools, kind of cut material, cutting parameters and used machine; affects on various parameters. Instead of required parameters need to be measured such as temperature, vibration, and tool wear that emerged during cutting process; detailed analysis of the sound emerged during cutting process will provide detection of various data that included in the cutting process by the much more easy and economic way. The relation between cutting parameters and sound is being identified.

Keywords: cutting process, sound processing, intelligent late, sound analysis

Procedia PDF Downloads 303
8500 The Effect of Lepidium Meyenii on Viability, Motility, and Sperm Morphology in Treatment of Infertility Among Adult Male Wistar Rats

Authors: Arefeh Sabzipour

Abstract:

In the present work, the effect of Lepidium meyenii on viability, motility, and sperm morphology in the treatment of infertility of adult male Wistar rats was evaluated. 21 male Wistar rats were adopted, fed and brought up in the same conditions to reach the weight of 230±5 g. after that, they were randomly divided into three groups, including two experimental groups and one control group, each group consisted of 7 rates. Lepidium meyenii was extracted and pulverized. Mice in the control group were treated with distilled water, and experimental groups were gavage with alcoholic juice extracted from Lepidium meyenii once a day for 10 consecutive days. After rates were killed, the testes were isolated. Different parameters includes semen volume in mice, sperm count, sperm motility, morphology, and viability, were evaluated. The results shows that sperm motility and sperm survival indices were significantly different between groups, and sperm count and sperm morphology indices were not significantly different. Sperm motility index in intervention group 1 was equal to 77.00±2.499 and was significantly higher than the one in intervention group two (70.14±3.579, P=0.018) and control group (69.43 ±7.323, P=0.018). Sperm survival index was 91.14 ± 2.410 in intervention group 1, 79.43± 5.062 in intervention group 2, and 76.71.6.651 in the control group (P<0.001). Based on the results of the present study, Lepidium meyenii had great effect on improving sperm indices of mice, especially sperm motility index and sperm survival index. Sperm count index and sperm morphology index, although increased, were not statistically significant.

Keywords: infertility, lepidium, sperm morphology, sperm survival

Procedia PDF Downloads 48
8499 A Review on Parametric Optimization of Casting Processes Using Optimization Techniques

Authors: Bhrugesh Radadiya, Jaydeep Shah

Abstract:

In Indian foundry industry, there is a need of defect free casting with minimum production cost in short lead time. Casting defect is a very large issue in foundry shop which increases the rejection rate of casting and wastage of materials. The various parameters influences on casting process such as mold machine related parameters, green sand related parameters, cast metal related parameters, mold related parameters and shake out related parameters. The mold related parameters are most influences on casting defects in sand casting process. This paper review the casting produced by foundry with shrinkage and blow holes as a major defects was analyzed and identified that mold related parameters such as mold temperature, pouring temperature and runner size were not properly set in sand casting process. These parameters were optimized using different optimization techniques such as Taguchi method, Response surface methodology, Genetic algorithm and Teaching-learning based optimization algorithm. Finally, concluded that a Teaching-learning based optimization algorithm give better result than other optimization techniques.

Keywords: casting defects, genetic algorithm, parametric optimization, Taguchi method, TLBO algorithm

Procedia PDF Downloads 701
8498 The Effect of Lepidium Meyenii on Viability, Motility, and Sperm Morphology in Treatment of Infertility Among Adult Male Wistar Rats

Authors: Arefeh Sabzipour

Abstract:

In the present work, the effect of Lepidium meyenii on viability, motility, and sperm morphology in the treatment of infertility of adult male Wistar rats was evaluated. 21 male Wistar rats were adopted, fed and brought up in the same conditions to reach the weight of 230±5 g. after that, they were randomly divided into three groups, including two experimental groups and one control group, each group consisted of 7 rates. Lepidium meyenii was extracted and pulverized. Mice in the control group were treated with distilled water, and experimental groups were gavage with alcoholic juice extracted from Lepidium meyenii once a day for 10 consecutive days. After rates were killed, the testes were isolated. Different parameters includes semen volume in mice, sperm count, sperm motility, morphology, and viability, were evaluated. The results shows that sperm motility and sperm survival indices were significantly different between groups, and sperm count and sperm morphology indices were not significantly different. Sperm motility index in intervention group 1 was equal to 77.00±2.499 and was significantly higher than the one in intervention group two (70.14±3.579, P=0.018) and control group (69.43 ±7.323, P=0.018). Sperm survival index was 91.14 ± 2.410 in intervention group 1, 79.43± 5.062 in intervention group 2, and 76.71.6.651 in the control group (P<0.001). Based on the results of the present study, Lepidium meyenii had great effect on improving sperm indices of mice, especially sperm motility index and sperm survival index. Sperm count index and sperm morphology index, although increased, were not statistically significant.

Keywords: infertility, lepidium meyenii, sperm morphology, sperm survival

Procedia PDF Downloads 47
8497 The Effect of Lepidium Meyenii on Viability, Motility, and Sperm Morphology in Treatment of Infertility Among Adult Male Wistar Rats

Authors: Arefeh Sabzipour

Abstract:

In the present work, the effect of Lepidium meyenii on viability, motility, and sperm morphology in the treatment of infertility of adult male Wistar rats was evaluated. 21 male Wistar rats were adopted, fed and brought up in the same conditions to reach the weight of 230±5 g. after that they were randomly divided into three groups including two experimental groups and one control group, each group consisted of 7 rates. Lepidium meyenii was extracted and pulverized. Mice in the control group were treated with distilled water and experimental groups were gavage with alcoholic juice extracted from Lepidium meyenii once a day for 10 consecutive days. After rates were killed, the testes were isolated. Different parameters includes semen volume in mice, sperm count, sperm motility, morphology, and viability were evaluated. The results shows that sperm motility and sperm survival indices were significantly different between groups and sperm count and sperm morphology indices were not significantly different. Sperm motility index in intervention group 1 was equal to 77.00±2.499 and was significantly higher than the one in intervention group two (70.14±3.579, P=0.018) and control group (69.43 ±7.323, P=0.018). Sperm survival index was 91.14 ± 2.410 in intervention group 1, 79.43± 5.062 in intervention group 2, and 76.71.6.651 in control group (P<0.001). Based on the results of the present study, Lepidium meyenii had great effect on improving sperm indices of mice, especially sperm motility index and sperm survival index. Sperm count index and sperm morphology index, although increased, were not statistically significant.

Keywords: infertility, Lepidium meyenii, sperm morphology, sperm survival

Procedia PDF Downloads 56
8496 Serological Evidence of Enzootic Bovine Leukosis in Dairy Cattle Herds in the United Arab Emirates

Authors: Nabeeha Hassan Abdel Jalil, Lulwa Saeed Al Badi, Mouza Ghafan Alkhyeli, Khaja Mohteshamuddin, Ahmad Al Aiyan, Mohamed Elfatih Hamad, Robert Barigye

Abstract:

The present study was done to elucidate the prevalence of enzootic bovine leucosis (EBL) in the UAE, the seroprevalence rates of EBL in dairy herds from the Al Ain area, Abu Dhabi (AD) and indigenous cattle at the Al Ain livestock market (AALM) were assessed. Of the 949 sera tested by ELISA, 657 were from adult Holstein-Friesians from three farms and 292 from indigenous cattle at the AALM. The level of significance between the proportions of seropositive cattle were analyzed by the Marascuilo procedure and questionnaire data on husbandry and biosecurity practices evaluated. Overall, the aggregated farm and AALM data demonstrated a seroprevalence of 25.9%, compared to 37.0% for the study farms, and 1.0% for the indigenous cattle. Additionally, the seroprevalence rates at farms #1, #2 and #3 were 54.7%, 0.0%, and 26.3% respectively. Except for farm #2 and the AALM, statistically significant differences were noted between the proportions of seropositive cattle for farms #1 and #2 (Critical Range or CR=0.0803), farms #1 and #3 (p=0.1069), and farms #2 and #3 (CR=0.0707), farm #1 and the AALM (CR=0.0819), and farm #3 and the AALM (CR=0.0726). Also, the proportions of seropositive animals on farm #1 were 9.8%, 59.8%, 29.3%, and 1.2% in the 12-36, 37-72, 73-108, and 109-144-mo-old age groups respectively compared to 21.5%, 60.8%, 15.2%, and 2.5% in the respective age groups for farm #2. On both farms and the AALM, the 37-72-mo-old age group showed the highest EBL seroprevalence rate while all the 57 cattle on farm #2 were seronegative. Additionally, farms #1 and #3 had 3,130 and 2,828 intensively managed Holstein-Friesian cattle respectively, and all animals were routinely immunized against several diseases except EBL. On both farms #1 and #3, artificial breeding was practiced using semen sourced from the USA, and USA and Canada respectively, all farms routinely quarantined new stock, and farm #1 previously imported dairy cattle from an unspecified country, and farm #3 from the Netherlands, Australia and South Africa. While farm #1 provided no information on animal nutrition, farm #3 cited using hay, concentrates, and ad lib water. To the authors’ best knowledge, this is the first serological evidence of EBL in the UAE and as previously reported, the seroprevalence rates are comparatively higher in the intensively managed dairy herds than in indigenous cattle. As two of the study farms previously sourced cattle and semen from overseas, biosecurity protocols need to be revisited to avoid inadvertent EBL incursion and the possibility of regional transboundary disease spread also needs to be assessed. After the proposed molecular studies have adduced additional data, the relevant UAE animal health authorities may need to develop evidence-based EBL control policies and programs.

Keywords: cattle, enzootic bovine leukosis, seroprevalence, UAE

Procedia PDF Downloads 114
8495 Optimizing of Machining Parameters of Plastic Material Using Taguchi Method

Authors: Jumazulhisham Abdul Shukor, Mohd. Sazali Said, Roshanizah Harun, Shuib Husin, Ahmad Razlee Ab Kadir

Abstract:

This paper applies Taguchi Optimization Method in determining the best machining parameters for pocket milling process on Polypropylene (PP) using CNC milling machine where the surface roughness is considered and the Carbide inserts cutting tool are used. Three machining parameters; speed, feed rate and depth of cut are investigated along three levels; low, medium and high of each parameter (Taguchi Orthogonal Arrays). The setting of machining parameters were determined by using Taguchi Method and the Signal-to-Noise (S/N) ratio are assessed to define the optimal levels and to predict the effect of surface roughness with assigned parameters based on L9. The final experimental outcomes are presented to prove the optimization parameters recommended by manufacturer are accurate.

Keywords: inserts, milling process, signal-to-noise (S/N) ratio, surface roughness, Taguchi Optimization Method

Procedia PDF Downloads 599
8494 Body Fluids Identification by Raman Spectroscopy and Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Authors: Huixia Shi, Can Hu, Jun Zhu, Hongling Guo, Haiyan Li, Hongyan Du

Abstract:

The identification of human body fluids during forensic investigations is a critical step to determine key details, and present strong evidence to testify criminal in a case. With the popularity of DNA and improved detection technology, the potential question must be revolved that whether the suspect’s DNA derived from saliva or semen, menstrual or peripheral blood, how to identify the red substance or aged blood traces on the spot is blood; How to determine who contribute the right one in mixed stains. In recent years, molecular approaches have been developing increasingly on mRNA, miRNA, DNA methylation and microbial markers, but appear expensive, time-consuming, and destructive disadvantages. Physicochemical methods are utilized frequently such us scanning electron microscopy/energy spectroscopy and X-ray fluorescence and so on, but results only showing one or two characteristics of body fluid itself and that out of working in unknown or mixed body fluid stains. This paper focuses on using chemistry methods Raman spectroscopy and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to discriminate species of peripheral blood, menstrual blood, semen, saliva, vaginal secretions, urine or sweat. Firstly, non-destructive, confirmatory, convenient and fast Raman spectroscopy method combined with more accurate matrix-assisted laser desorption/ionization time-of-flight mass spectrometry method can totally distinguish one from other body fluids. Secondly, 11 spectral signatures and specific metabolic molecules have been obtained by analysis results after 70 samples detected. Thirdly, Raman results showed peripheral and menstrual blood, saliva and vaginal have highly similar spectroscopic features. Advanced statistical analysis of the multiple Raman spectra must be requested to classify one to another. On the other hand, it seems that the lactic acid can differentiate peripheral and menstrual blood detected by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, but that is not a specific metabolic molecule, more sensitivity ones will be analyzed in a forward study. These results demonstrate the great potential of the developed chemistry methods for forensic applications, although more work is needed for method validation.

Keywords: body fluids, identification, Raman spectroscopy, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

Procedia PDF Downloads 102
8493 Effect of Design Parameters on a Two Stage Launch Vehicle Performance

Authors: Assem Sallam, Aly Elzahaby, Ahmed Makled, Mohamed Khalil

Abstract:

Change in design parameters of launch vehicle affects its overall flight path trajectory. In this paper, several design parameters are introduced to study their effect. Selected parameters are the launch vehicle mass, which is presented in the form of payload mass, the maximum allowable angle of attack the launch vehicle can withstand, the flight path angle that is predefined for the launch vehicle second stage, the required inclination and its effect on the launch azimuth and finally by changing the launch pad coordinate. Selected design parameters are studied for their effect on the variation of altitude, ground range, absolute velocity and the flight path angle. The study gives a general mean of adjusting the design parameters to reach the required launch vehicle performance.

Keywords: launch vehicle azimuth, launch vehicle trajectory, launch vehicle payload, launch pad location

Procedia PDF Downloads 285
8492 Symbolic Analysis of Power Spectrum of CMOS Cross Couple Oscillator

Authors: Kittipong Tripetch

Abstract:

This paper proposes for the first time symbolic formula of the power spectrum of cross couple oscillator and its modified circuit. Many principle existed to derived power spectrum in microwave textbook such as impedance, admittance parameters, ABCD, H parameters, etc. It can be compared by graph of power spectrum which methodology is the best from the point of view of practical measurement setup such as condition of impedance parameter which used superposition of current to derived (its current injection of the other port of the circuit is zero, which is impossible in reality). Four Graphs of impedance parameters of cross couple oscillator is proposed. After that four graphs of Scattering parameters of cross couple oscillator will be shown.

Keywords: optimization, power spectrum, impedance parameters, scattering parameter

Procedia PDF Downloads 432
8491 Optimization of End Milling Process Parameters for Minimization of Surface Roughness of AISI D2 Steel

Authors: Pankaj Chandna, Dinesh Kumar

Abstract:

The present work analyses different parameters of end milling to minimize the surface roughness for AISI D2 steel. D2 Steel is generally used for stamping or forming dies, punches, forming rolls, knives, slitters, shear blades, tools, scrap choppers, tyre shredders etc. Surface roughness is one of the main indices that determines the quality of machined products and is influenced by various cutting parameters. In machining operations, achieving desired surface quality by optimization of machining parameters, is a challenging job. In case of mating components the surface roughness become more essential and is influenced by the cutting parameters, because, these quality structures are highly correlated and are expected to be influenced directly or indirectly by the direct effect of process parameters or their interactive effects (i.e. on process environment). In this work, the effects of selected process parameters on surface roughness and subsequent setting of parameters with the levels have been accomplished by Taguchi’s parameter design approach. The experiments have been performed as per the combination of levels of different process parameters suggested by L9 orthogonal array. Experimental investigation of the end milling of AISI D2 steel with carbide tool by varying feed, speed and depth of cut and the surface roughness has been measured using surface roughness tester. Analyses of variance have been performed for mean and signal-to-noise ratio to estimate the contribution of the different process parameters on the process.

Keywords: D2 steel, orthogonal array, optimization, surface roughness, Taguchi methodology

Procedia PDF Downloads 521
8490 Dissolved Oxygen Prediction Using Support Vector Machine

Authors: Sorayya Malek, Mogeeb Mosleh, Sharifah M. Syed

Abstract:

In this study, Support Vector Machine (SVM) technique was applied to predict the dichotomized value of Dissolved oxygen (DO) from two freshwater lakes namely Chini and Bera Lake (Malaysia). Data sample contained 11 parameters for water quality features from year 2005 until 2009. All data parameters were used to predicate the dissolved oxygen concentration which was dichotomized into 3 different levels (High, Medium, and Low). The input parameters were ranked, and forward selection method was applied to determine the optimum parameters that yield the lowest errors, and highest accuracy. Initial results showed that pH, water temperature, and conductivity are the most important parameters that significantly affect the predication of DO. Then, SVM model was applied using the Anova kernel with those parameters yielded 74% accuracy rate. We concluded that using SVM models to predicate the DO is feasible, and using dichotomized value of DO yields higher prediction accuracy than using precise DO value.

Keywords: dissolved oxygen, water quality, predication DO, support vector machine

Procedia PDF Downloads 259
8489 Old Swimmers Tire Quickly: The Effect of Time on Quality of Thawed versus Washed Sperm

Authors: Emily Hamilton, Adiel Kahana, Ron Hauser, Shimi Barda

Abstract:

BACKGROUND: In the male fertility and sperm bank unit of Tel Aviv Sourasky medical center, women are treated with intrauterine insemination (IUI) using washed sperm from their partner or thawed sperm from a selected donor. In most cases, the women perform the IUI treatment in Sourasky, but sometimes they ask to undergo the insemination procedure in another clinic with their own fertility doctor. In these cases, the sperm sample is prepared at the Sourasky lab and the patient is inseminated after arriving to her doctor. Our laboratory has previously found that time negatively affects several parameters of thawed sperm, and we estimate that it has more severe and significant effect than on washed sperm. AIM: To examine the effect of time on the quality of washed sperm versus thawed sperm. METHODS: Sperm samples were collected from men referred for semen analysis. Each ejaculate was allowed to liquefy for at least 20 min at 37°C and analyzed for sperm motility and vitality percentage and DNA fragmentation index (Time 0). Subsequently, 1ml of the sample was divided into two parts, 1st part was washed only and the 2nd part was washed, frozen and thawed. Time 1 analysis occurred immediately after sperm washing or thawing. Time 2 analysis occurred 75 minutes after time 1. Statistical analysis was performed using Student t-test. P values<0.05 were considered significant. RESULTS: Preliminary data showed that time had a greater impact on the average percentages of sperm motility and vitality in thawed compared to washed sperm samples (26%±10% vs. 21%±10% and 21%±9% vs. 9%±10%, respectively). An additional trend towards increased average DNA fragmentation percentage in thawed samples compared to washed samples was observed (46%±18% vs. 25%±24%). CONCLUSION: Time negatively effects sperm quality. The effect is greater in thawed samples compared to fresh samples.

Keywords: ART, male fertility, sperm cryopreservation, sperm quality

Procedia PDF Downloads 162
8488 Optimum Er: YAG Laser Parameters for Orthodontic Composite Debonding: An in vitro Study

Authors: Mohammad Zamzam, Wesam Bachir, Imad Asaad

Abstract:

Several studies have produced estimates of Er:YAG laser parameters and specifications but there is still insufficient data for reliable selection of laser parameters. As a consequence, there is a heightened need for ideal specifications of Er:YAG laser to reduce the amount of enamel ablation. The objective of this paper is to investigate the influence of Er:YAG laser parameters, energy level and pulse duration, on orthodontic composite removal after bracket debonding. The sample consisted of 45 cuboids of orthodontic composite made by plastic moulds. The samples were divided into three groups, each was irradiated with Er:YAG laser set at different energy levels and three values for pulse durations (50 µs, 100 µs, and 300 µs). Geometrical parameters (depth and area) of cavities formed by laser irradiation were determined. ANCOVA test showed statistically significant difference (p < 0.0.5) between the groups indicating a potential effect of laser pulse duration on the geometrical parameters after controlling laser energy level. A post-hoc Bonferroni test ranked the 50µ Er:YAG laser pulse as the most influential factor for all geometrical parameters in removing remnant composite from enamel surface. Also, 300 mJ laser pulses caused the largest removal of the composite. The results of the present study demonstrated the efficacy of 50 µs and 300 mJ Er:YAG laser pulse for removal of remnant orthodontic composite.

Keywords: enamel, Er:YAG, geometrical parameters, orthodontic composite, remnant composite

Procedia PDF Downloads 525
8487 Parametric Dependence of the Advection-Diffusion Equation in Two Dimensions

Authors: Matheus Fernando Pereira, Varese Salvador Timoteo

Abstract:

In this work, we have solved the two-dimensional advection-diffusion equation numerically for a spatially dependent solute dispersion along non-uniform flow with a pulse type source in order to make a systematic study on the influence of medium heterogeneity, initial flow velocity, and initial dispersion coefficient parameters on the solutions of the equation. The behavior of the solutions is then investigated as we change the three parameters independently. Our results show that even though the parameters represent different physical features of the system, the effect on their variation is very similar. We also observe that the effects caused by the parameters on the concentration depend on the distance from the source. Finally, our numerical results are in good agreement with the exact solutions for all values of the parameters we used in our analysis.

Keywords: advection-diffusion equation, dispersion, numerical methods, pulse-type source

Procedia PDF Downloads 193
8486 Effect of Soil and Material Characteristics on Safety of Concrete Structures Including SSI

Authors: A. E. Kurtoglu, A. Cevik, M. Bilgehan

Abstract:

In this parametric study, effect of soil and material characteristics on safety of structures is investigated. The soil parameters such as shear strength, unit weight; geometrical parameters of the structure such as foundation depth and height of building; and material properties such as weight of concrete were selected as input parameters. A real accelerogram of 1989 El-Centro earthquake recorded by the USGS in Imperial Valley is used for this study. It is contained in the standard Strong Motion CD-ROM (SMC) format, which can be recognized and interpreted by FEM software used. The soil-structure interaction model subjected to above-mentioned earthquake was analyzed for 729 cases. Effect of input parameters on safety factor of the soil-structure system was then investigated and the interaction between the input and output parameters is presented in graphical form. Findings showed that all input parameters have significant effects on factor of safety results.

Keywords: factor of safety, finite element method, safety of structures, soil structure interaction

Procedia PDF Downloads 474
8485 To Individualisation of Subject, Donar, by Determination of Serological Markers from Obtain Biological Fluid at Crime Scene

Authors: Arun Kumar, Ravindra Pal Verma, Harsh Sharma, Shani Kumar

Abstract:

For the present study samples was collected from 20 donors with unknown blood group and secretor status had been determined from saliva by using biological fluid. ABO typing on the concentrated samples was successfully performed after 1 month of storage. Urine stained clothing samples are often submitted to forensic science laboratories for ABH blood group antigen determination. The serogenetic markers of semen stains submitted can be used to determine the origin of any of these samples. ABH blood group substances have previously been identified from urine. ABH blood group substance is low in urine in comparison with other body fluids.

Keywords: ABH blood group, crime scene, serological markers, body fluids and urine

Procedia PDF Downloads 549
8484 Automatic Censoring in K-Distribution for Multiple Targets Situations

Authors: Naime Boudemagh, Zoheir Hammoudi

Abstract:

The parameters estimation of the K-distribution is an essential part in radar detection. In fact, presence of interfering targets in reference cells causes a decrease in detection performances. In such situation, the estimate of the shape and the scale parameters are far from the actual values. In the order to avoid interfering targets, we propose an Automatic Censoring (AC) algorithm of radar interfering targets in K-distribution. The censoring technique used in this work offers a good discrimination between homogeneous and non-homogeneous environments. The homogeneous population is then used to estimate the unknown parameters by the classical Method of Moment (MOM). The AC algorithm does not need any prior information about the clutter parameters nor does it require both the number and the position of interfering targets. The accuracy of the estimation parameters obtained by this algorithm are validated and compared to various actual values of the shape parameter, using Monte Carlo simulations, this latter show that the probability of censing in multiple target situations are in good agreement.

Keywords: parameters estimation, method of moments, automatic censoring, K distribution

Procedia PDF Downloads 349
8483 Implementation of Clinical Monitoring System of Physiological Parameters

Authors: Abdesselam Babouri, Ahcène Lemzadmi, M Rahmane, B. Belhadi, N. Abouchi

Abstract:

Medical monitoring aims at monitoring and remotely controlling the vital physiological parameters of the patient. The physiological sensors provide repetitive measurements of these parameters in the form of electrical signals that vary continuously over time. Various measures allow informing us about the health of the person's physiological data (weight, blood pressure, heart rate or specific to a disease), environmental conditions (temperature, humidity, light, noise level) and displacement and movements (physical efforts and the completion of major daily living activities). The collected data will allow monitoring the patient’s condition and alerting in case of modification. They are also used in the diagnosis and decision making on medical treatment and the health of the patient. This work presents the implementation of a monitoring system to be used for the control of physiological parameters.

Keywords: clinical monitoring, physiological parameters, biomedical sensors, personal health

Procedia PDF Downloads 438
8482 Analysis of the IEEE 802.15.4 MAC Parameters to Achive Lower Packet Loss Rates

Authors: Imen Bouazzi

Abstract:

The IEEE-802.15.4 standard utilizes the CSMA-CA mechanism to control nodes access to the shared wireless communication medium. It is becoming the popular choice for various applications of surveillance and control used in wireless sensor network (WSN). The benefit of this standard is evaluated regarding of the packet loss probability who depends on the configuration of IEEE 802.15.4 MAC parameters and the traffic load. Our exigency is to evaluate the effects of various configurable MAC parameters on the performance of beaconless IEEE 802.15.4 networks under different traffic loads, static values of IEEE 802.15.4 MAC parameters (macMinBE, macMaxCSMABackoffs, and macMaxFrame Retries) will be evaluated. To performance analysis, we use ns-2[2] network simulator.

Keywords: WSN, packet loss, CSMA/CA, IEEE-802.15.4

Procedia PDF Downloads 303
8481 Optimization of Friction Stir Spot Welding Process Parameters for Joining 6061 Aluminum Alloy Using Taguchi Method

Authors: Mohammed A. Tashkandi, Jawdat A. Al-Jarrah, Masoud Ibrahim

Abstract:

This paper investigates the shear strength of the joints produced by friction stir spot welding process (FSSW). FSSW parameters such as tool rotational speed, plunge depth, shoulder diameter of the welding tool and dwell time play the major role in determining the shear strength of the joints. The effect of these four parameters on FSSW process as well as the shear strength of the welded joints was studied via five levels of each parameter. Taguchi method was used to minimize the number of experiments required to determine the fracture load of the friction stir spot-welded joints by incorporating independently controllable FSSW parameters. Taguchi analysis was applied to optimize the FSSW parameters to attain the maximum shear strength of the spot weld for this type of aluminum alloy.

Keywords: Friction Stir Spot Welding, Al6061 alloy, Shear Strength, FSSW process parameters

Procedia PDF Downloads 403
8480 Room Level Indoor Localization Using Relevant Channel Impulse Response Parameters

Authors: Raida Zouari, Iness Ahriz, Rafik Zayani, Ali Dziri, Ridha Bouallegue

Abstract:

This paper proposes a room level indoor localization algorithm based on the use Multi-Layer Neural Network (MLNN) classifiers and one versus one strategy. Seven parameters of the Channel Impulse Response (CIR) were used and Gram-Shmidt Orthogonalization was performed to study the relevance of the extracted parameters. Simulation results show that when relevant CIR parameters are used as position fingerprint and when optimal MLNN architecture is selected good room level localization score can be achieved. The current study showed also that some of the CIR parameters are not correlated to the location and can decrease the localization performance of the system.

Keywords: mobile indoor localization, multi-layer neural network (MLNN), channel impulse response (CIR), Gram-Shmidt orthogonalization

Procedia PDF Downloads 329
8479 Parameters Tuning of a PID Controller on a DC Motor Using Honey Bee and Genetic Algorithms

Authors: Saeid Jalilzadeh

Abstract:

PID controllers are widely used to control the industrial plants because of their robustness and simple structures. Tuning of the controller's parameters to get a desired response is difficult and time consuming. With the development of computer technology and artificial intelligence in automatic control field, all kinds of parameters tuning methods of PID controller have emerged in endlessly, which bring much energy for the study of PID controller, but many advanced tuning methods behave not so perfect as to be expected. Honey Bee algorithm (HBA) and genetic algorithm (GA) are extensively used for real parameter optimization in diverse fields of study. This paper describes an application of HBA and GA to the problem of designing a PID controller whose parameters comprise proportionality constant, integral constant and derivative constant. Presence of three parameters to optimize makes the task of designing a PID controller more challenging than conventional P, PI, and PD controllers design. The suitability of the proposed approach has been demonstrated through computer simulation using MATLAB/SIMULINK.

Keywords: controller, GA, optimization, PID, PSO

Procedia PDF Downloads 514