Search results for: microbiology
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 96

Search results for: microbiology

6 Microbial and SARS-CoV-2 Efficiency Analysis of Froumann HEPA Filter Air Cleaner Brand

Authors: Serap Gedikli, Hakan Çakmak, M. Buğra Güldiken, Duygu Yalnızoğlu

Abstract:

Air, which is necessary for living things to survive; while it carries some useful substances in it, it can also carry foreign particles of different sizes that may be harmful to the health. All airborne organic substances of biological origin, including bacteria, fungi, fungal spores, viruses, pollen, and their components, are called "bioaerosols". Nowadays, everyone spends most of their time in closed areas such as home, workplace, school, etc. Although it is known that outdoor air pollution affects health, it is not known that indoor air pollution has harmful effects in terms of health. In this study, indoor air microbial load and SARS-CoV-2 virus cleaning efficiency of Froumann brand air cleaners were studied. This work in 300 m³, 600 m³, and 1000 m³ completely closed areas without any air circulation with Froumann N80, N90, and N100 air-cleaning devices. Analyzes were performed for both areas at 60 minutes before and after the device was operated using a particle measuring device (Particles Plus 7302) and an air sampler (Mas-100 ECO). The measurements were taken by placing the test equipment 1.5-2 m away from the air cleaner. At the same time, the efficiency of the HEPA filter was evaluated by taking samples from the air outlet point of the HEPA filter using the air sampling device (Mas-100 ECO) after the device was started. Nutrient agar and malt agar are used as total mesophilic bacteria and total fungi. The number of colony-forming units per m³ (cfu/m³) was calculated by counting colonies in Petri dishes after incubation for 48 hours at 37°C for bacteria and 72 hours at 30°C for fungi. The change in the number of colonies and the decrease in the microbial load was calculated as a percentage value. SARS-CoV-2 activity analysis studies were carried out by İnönü University Microbiology Department in accordance with the World Health Organization regulations. Finally, the HEPA filter in the devices used was taken and kept under a certain temperature and humidity, and the change in the microbial load on it was monitored over a 6-month period. At the end of the studies, a 91%-94% reduction was determined in the total mesophilic bacteria count of Frouman brand N80, N90, and N100 model air cleaners. A decrease of 94%-96% was detected in the total number of yeast/molds. HEPA filter efficiency was evaluated, and at the end of the analysis, 98% of the bacterial load and approximately 100% of yeast/mold load at the HEPA filter air outlet point were decreased. According to the SARS- CoV-2 analysis results, when the device is operating at the medium airflow level 3, it can filter virus-carrying aerosols by 99%. As a result, it was determined that the Froumann model air cleaner was effective in controlling and reducing the microbial load in the indoor air.

Keywords: HEPA filter, indoor air quality, microbial load, SARS-CoV-2

Procedia PDF Downloads 164
5 Control of an Outbreak of Vancomycin-Resistant Enterococci in a Tunisian Teaching Hospital

Authors: Hela Ghali, Sihem Ben Fredj, Mohamed Ben Rejeb, Sawssen Layouni, Salwa Khefacha, Lamine Dhidah, Houyem Said Laatiri

Abstract:

Background: Antimicrobial resistance is a growing threat to public health and motivates to improve prevention and control programs both at international (WHO) and national levels. Despite their low pathogenicity, vancomycin-resistant enterococci (VRE) are common nosocomial pathogens in several countries. The high potential for transmission of VRE between patients and the threat to send its resistance genes to other bacteria such as staphylococcus aureus already resistant to meticilin, justify strict control measures. Indeed, in Europe, the proportion of Enterococcus faecium responsible for invasive infections, varies from 1% to 35% in 2011 and less than 5% were resistant to vancomycin. In addition, it represents the second cause of urinary tract and wound infections and the third cause of nosocomial bacteremia in the United States. The nosocomial outbreaks of VRE have been mainly described in intensive care services, hematology-oncology and haemodialysis. An epidemic of VRE has affected our hospital and the objective of this work is to describe the measures put in place. Materials/Methods: Following the alert given by the service of plastic surgery concerning a patient carrier of VRE, a team of the prevention and healthcare security service (doctor + technician) made an investigation. A review of files was conducted to draw the synoptic table and the table of cases. Results: By contacting the microbiology laboratory, we have identified four other cases of VRE and who were hospitalized in Medical resuscitation department (2 cases, one of them was transferred to the Physical rehabilitation department), and Nephrology department (2 cases). The visit has allowed to detect several malfunctions in professional practice. A crisis cell has allowed to validate, coordinate and implement control measures following the recommendations of the Technical Center of nosocomial infections. In fact, the process was to technically isolate cases in their sector of hospitalization, to restrict the use of antibiotics, to strength measures of basic hygiene, and to make a screening by rectal swab for both cases and contacts (other patients and health staff). These measures have helped to control the situation and no other case has been reported for a month. 2 new cases have been detected in the intensive care unit after a month. However, these are short-term strategies, and other measures in the medium and long term should be taken into account in order to face similar outbreaks. Conclusion: The efforts to control the outbreak were not efficient since 2 new cases have been reported after a month. Therefore, a continuous monitoring in order to detect new cases earlier is crucial to minimize the dissemination of VRE.

Keywords: hospitals, nosocomial infection, outbreak, vancomycin-resistant enterococci

Procedia PDF Downloads 272
4 Human Immuno-Deficiency Virus Co-Infection with Hepatitis B Virus and Baseline Cd4+ T Cell Count among Patients Attending a Tertiary Care Hospital, Nepal

Authors: Soma Kanta Baral

Abstract:

Background: Since 1981, when the first AIDS case was reported, worldwide, more than 34 million people have been infected with HIV. Almost 95 percent of the people infected with HIV live in developing countries. As HBV & HIV share similar routes of transmission by sexual intercourse or drug use by parenteral injection, co-infection is common. Because of the limited access to healthcare & HIV treatment in developing countries, HIV-infected individuals are present late for care. Enumeration of CD4+ T cell count at the time of diagnosis has been useful to initiate the therapy in HIV infected individuals. The baseline CD4+ T cell count shows high immunological variability among patients. Methods: This prospective study was done in the serology section of the Department of Microbiology over a period of one year from august 2012 to July 2013. A total of 13037 individuals subjected for HIV test were included in the study comprising of 4982 males & 8055 females. Blood sample was collected by vein puncture aseptically with standard operational procedure in clean & dry test-tube. All blood samples were screened for HIV as described by WHO algorithm by Immuno-chromatography rapid kits. Further confirmation was done by biokit ELISA method as per the manufacturer’s guidelines. After informed consent, HIV positive individuals were screened for HBsAg by Immuno-chromatography rapid kits (Hepacard). Further confirmation was done by biokit ELISA method as per the manufacturer’s guidelines. EDTA blood samples were collected from the HIV sero-positive individuals for baseline CD4+ T count. Then, CD4+ T cells count was determined by using FACS Calibur Flow Cytometer (BD). Results: Among 13037 individuals screened for HIV, 104 (0.8%) were found to be infected comprising of 69(66.34%) males & 35 (33.65%) females. The study showed that the high infection was noted in housewives (28.7%), active age group (30.76%), rural area (56.7%) & in heterosexual route (80.9%) of transmission. Out of total HIV infected individuals, distribution of HBV co-infection was found to be 6(5.7%). All co- infected individuals were married, male, above the age of 25 years & heterosexual route of transmission. Baseline CD4+ T cell count of HIV infected patient was found higher (mean CD4+ T cell count; 283cells/cu.mm) than HBV co-infected patients (mean CD4+ T cell count; 91 cells/cu.mm). Majority (77.2%) of HIV infected & all co-infected individuals were presented in our center late (CD4+ T cell count;< 350/cu. mm) for diagnosis and care. Majority of co- infected 4 (80%) were late presented with advanced AIDS stage (CD4+ count; <200/cu.mm). Conclusions: The study showed a high percentage of HIV sero-positive & co- infected individuals. Baseline CD4+ T cell count of majority of HIV infected individuals was found to be low. Hence, more sustained and vigorous awareness campaigns & counseling still need to be done in order to promote early diagnosis and management.

Keywords: HIV/AIDS, HBsAg, co-infection, CD4+

Procedia PDF Downloads 186
3 Endometrial Biopsy Curettage vs Endometrial Aspiration: Better Modality in Female Genital Tuberculosis

Authors: Rupali Bhatia, Deepthi Nair, Geetika Khanna, Seema Singhal

Abstract:

Introduction: Genital tract tuberculosis is a chronic disease (caused by reactivation of organisms from systemic distribution of Mycobacterium tuberculosis) that often presents with low grade symptoms and non-specific complaints. Patients with genital tuberculosis are usually young women seeking workup and treatment for infertility. Infertility is the commonest presentation due to involvement of the fallopian tubes, endometrium and ovarian damage with poor ovarian volume and reserve. The diagnosis of genital tuberculosis is difficult because of the fact that it is a silent invader of genital tract. Since tissue cannot be obtained from fallopian tubes, the diagnosis is made by isolation of bacilli from endometrial tissue obtained by endometrial biopsy curettage and/or aspiration. Problems are associated with sampling technique as well as diagnostic modality due to lack of adequate sample volumes and the segregation of the sample for various diagnostic tests resulting in non-uniform distribution of microorganisms. Moreover, lack of an efficient sampling technique universally applicable for all specific diagnostic tests contributes to the diagnostic challenges. Endometrial sampling plays a key role in accurate diagnosis of female genital tuberculosis. It may be done by 2 methods viz. endometrial curettage and endometrial aspiration. Both endometrial curettage and aspirate have their own limitations as curettage picks up strip of the endometrium from one of the walls of the uterine cavity including tubal osteal areas whereas aspirate obtains total tissue with exfoliated cells present in the secretory fluid of the endometrial cavity. Further, sparse and uneven distribution of the bacilli remains a major factor contributing to the limitations of the techniques. The sample that is obtained by either technique is subjected to histopathological examination, AFB staining, culture and PCR. Aim: Comparison of the sampling techniques viz. endometrial biopsy curettage and endometrial aspiration using different laboratory methods of histopathology, cytology, microbiology and molecular biology. Method: In a hospital based observational study, 75 Indian females suspected of genital tuberculosis were selected on the basis of inclusion criteria. The women underwent endometrial tissue sampling using Novaks biopsy curette and Karmans cannula. One part of the specimen obtained was sent in formalin solution for histopathological testing and another part was sent in normal saline for acid fast bacilli smear, culture and polymerase chain reaction. The results so obtained were correlated using coefficient of correlation and chi square test. Result: Concordance of results showed moderate agreement between both the sampling techniques. Among HPE, AFB and PCR, maximum sensitivity was observed for PCR, though the specificity was not as high as other techniques. Conclusion: Statistically no significant difference was observed between the results obtained by the two sampling techniques. Therefore, one may use either EA or EB to obtain endometrial samples and avoid multiple sampling as both the techniques are equally efficient in diagnosing genital tuberculosis by HPE, AFB, culture or PCR.

Keywords: acid fast bacilli (AFB), histopatholgy examination (HPE), polymerase chain reaction (PCR), endometrial biopsy curettage

Procedia PDF Downloads 303
2 Evaluation of Antibiotic Resistance and Extended-Spectrum β-Lactamases Production Rates of Gram Negative Rods in a University Research and Practice Hospital, 2012-2015

Authors: Recep Kesli, Cengiz Demir, Onur Turkyilmaz, Hayriye Tokay

Abstract:

Objective: Gram-negative rods are a large group of bacteria, and include many families, genera, and species. Most clinical isolates belong to the family Enterobacteriaceae. Resistance due to the production of extended-spectrum β-lactamases (ESBLs) is a difficulty in the handling of Enterobacteriaceae infections, but other mechanisms of resistance are also emerging, leading to multidrug resistance and threatening to create panresistant species. We aimed in this study to evaluate resistance rates of Gram-negative rods bacteria isolated from clinical specimens in Microbiology Laboratory, Afyon Kocatepe University, ANS Research and Practice Hospital, between October 2012 and September 2015. Methods: The Gram-negative rods strains were identified by conventional methods and VITEK 2 automated identification system (bio-Mérieux, Marcy l’etoile, France). Antibiotic resistance tests were performed by both the Kirby-Bauer disk-diffusion and automated Antimicrobial Susceptibility Testing (AST, bio-Mérieux, Marcy l’etoile, France) methods. Disk diffusion results were evaluated according to the standards of Clinical and Laboratory Standards Institute (CLSI). Results: Of the totally isolated 1.701 Enterobacteriaceae strains 1434 (84,3%) were Klebsiella pneumoniae, 171 (10%) were Enterobacter spp., 96 (5.6%) were Proteus spp., and 639 Nonfermenting gram negatives, 477 (74.6%) were identified as Pseudomonas aeruginosa, 135 (21.1%) were Acinetobacter baumannii and 27 (4.3%) were Stenotrophomonas maltophilia. The ESBL positivity rate of the totally studied Enterobacteriaceae group were 30.4%. Antibiotic resistance rates for Klebsiella pneumoniae were as follows: amikacin 30.4%, gentamicin 40.1%, ampicillin-sulbactam 64.5%, cefepime 56.7%, cefoxitin 35.3%, ceftazidime 66.8%, ciprofloxacin 65.2%, ertapenem 22.8%, imipenem 20.5%, meropenem 20.5 %, and trimethoprim-sulfamethoxazole 50.1%, and for 114 Enterobacter spp were detected as; amikacin 26.3%, gentamicin 31.5%, cefepime 26.3%, ceftazidime 61.4%, ciprofloxacin 8.7%, ertapenem 8.7%, imipenem 12.2%, meropenem 12.2%, and trimethoprim-sulfamethoxazole 19.2 %. Resistance rates for Proteus spp. were: 24,3% meropenem, 26.2% imipenem, 20.2% amikacin 10.5% cefepim, 33.3% ciprofloxacin and levofloxacine, 31.6% ceftazidime, 20% ceftriaxone, 15.2% gentamicin, 26.6% amoxicillin-clavulanate, and 26.2% trimethoprim-sulfamethoxale. Resistance rates of P. aeruginosa was found as follows: Amikacin 32%, gentamicin 42 %, imipenem 43%, merpenem 43%, ciprofloxacin 50%, levofloxacin 52%, cefepim 38%, ceftazidim 63%, piperacillin/tacobactam 85%, for Acinetobacter baumannii; Amikacin 53.3%, gentamicin 56.6 %, imipenem 83%, merpenem 86%, ciprofloxacin 100%, ceftazidim 100%, piperacillin/tacobactam 85 %, colisitn 0 %, and for S. malthophilia; levofloxacin 66.6 % and trimethoprim/sulfamethoxozole 0 %. Conclusions: This study showed that resistance in Gram-negative rods was a serious clinical problem in our hospital and suggested the need to perform typification of the isolated bacteria with susceptibility testing regularly in the routine laboratory procedures. This application guided to empirical antibiotic treatment choices truly, as a consequence of the reality that each hospital shows different resistance profiles.

Keywords: antibiotic resistance, gram negative rods, ESBL, VITEK 2

Procedia PDF Downloads 298
1 Role of Toll Like Receptor-2 in Female Genital Tuberculosis Disease Infection and Its Severity

Authors: Swati Gautam, Salman Akhtar, S. P. Jaiswar, Amita Jain

Abstract:

Background: FGTB is now a major global health problem mostly in developing countries including India. In humans, Mycobacterium Tuberculosis (M.tb) is a causating agent of infection. High index of suspicion is required for early diagnosis due to asymptomatic presentation of FGTB disease. In macrophages Toll Like Receptor-2 (TLR-2) is one which mediated host’s immune response to M.tb. The expression of TLR-2 on macrophages is important to determine the fate of innate immune responses to M.tb. TLR-2 have two work. First its high expression on macrophages worsen the outer of infection and another side, it maintains M.tb to its dormant stage avoids activation of M.tb from latent phase. Single Nucleotide Polymorphism (SNP) of TLR-2 gene plays an important role in susceptibility to TB among different populations and subsequently, in the development of infertility. Methodology: This Case-Control study was done in the Department of Obs and Gynae and Department of Microbiology at King George’s Medical University, U.P, Lucknow, India. Total 300 subjects (150 Cases and 150 Controls) were enrolled in the study. All subjects were enrolled only after fulfilling the given inclusion and exclusion criteria. Inclusion criteria: Age 20-35 years, menstrual-irregularities, positive on Acid-Fast Bacilli (AFB), TB-PCR, (LJ/MGIT) culture in Endometrial Aspiration (EA). Exclusion criteria: Koch’s active, on ATT, PCOS, and Endometriosis fibroid women, positive on Gonococal and Chlamydia. Blood samples were collected in EDTA tubes from cases and healthy control women (HCW) and genomic DNA extraction was carried out by salting-out method. Genotyping of TLR2 genetic variants (Arg753Gln and Arg677Trp) were performed by using single amplification refractory mutation system (ARMS) PCR technique. PCR products were analyzed by electrophoresis on 1.2% agarose gel and visualized by gel-doc. Statistical analysis of the data was performed using the SPSS 16.3 software and computing odds ratio (OR) with 95% CI. Linkage Disequiliribium (LD) analysis was done by SNP stats online software. Results: In TLR-2 (Arg753Gln) polymorphism significant risk of FGTB observed with GG homozygous mutant genotype (OR=13, CI=0.71-237.7, p=0.05), AG heterozygous mutant genotype (OR=13.7, CI=0.76-248.06, p=0.03) however, G allele (OR=1.09, CI=0.78-1.52, p=0.67) individually was not associated with FGTB. In TLR-2 (Arg677Trp) polymorphism a significant risk of FGTB observed with TT homozygous mutant genotype (OR= 0.020, CI=0.001-0.341, p < 0.001), CT heterozygous mutant genotype (OR=0.53, CI=0.33-0.86, p=0.014) and T allele (OR=0.463, CI=0.32-0.66, p < 0.001). TT mutant genotype was only found in FGTB cases and frequency of CT heterozygous more in control group as compared to FGTB group. So, CT genotype worked as protective mutation for FGTB susceptibility group. In haplotype analysis of TLR-2 genetic variants, four possible combinations, i.e. (G-T, A-C, G-C, and A-T) were obtained. The frequency of haplotype A-C was significantly higher in FGTB cases (0.32). Control group did not show A-C haplotype and only found in FGTB cases. Conclusion: In conclusion, study showed a significant association with both genetic variants of TLR-2 of FGTB disease. Moreover, the presence of specific associated genotype/alleles suggest the possibility of disease severity and clinical approach aimed to prevent extensive damage by disease and also helpful for early detection of disease.

Keywords: ARMS, EDTA, FGTB, TLR

Procedia PDF Downloads 266