Search results for: malposition
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6

Search results for: malposition

6 Pregnant Women’s Views on a Trial of Posture for Fetal Malposition

Authors: Jennifer A. Barrowclough, Caroline A. Crowther, Bridget Kool

Abstract:

Fetal malposition in labour is associated with adverse maternal and infant health outcomes. Evidence for effective interventions for fetal malposition is inconclusive. The feasibility and design of a randomized controlled trial (RCT) of maternal posture to improve maternal and infant outcomes of malposition should be considered, based on the hypothesis that gravity corrects malposition. The aim was to assess pregnant women’s views on the acceptability of a future trial of maternal posture for fetal malposition in labour, and the enablers and barriers of participation. Method: An online anonymous survey of pregnant women was conducted in Auckland during 2020. Descriptive summaries of quantitative data used chi-square to assess differences in proportions. The influence of maternal characteristics on women’s responses was assessed using cross-tabulation. Free text responses were analysed thematically. Results: Respondents (n=206) were mostly aged26-35 years (75%), of 29-38 weeks gestation (71%), of European (40%) or Asian (36%) ethnicity, were evenly nulliparous or multiparous. Most women (76%) had heard of fetal malposition in labour however only 28% were aware of the use of maternal posture to correct this. Most women (86%) were interested in labour research. Although 37% indicated they would participate in a future RCT of posture for fetal malposition, nearly half (47%) were unsure and a further quarter (15%) indicated they would not participate. Comfort was the predominant concern (22%). Almost half of the respondents (49%) indicated they would consult their partner before deciding on participation in an RCT. Conclusions: Participation in a trial of maternal posture in labour can be enabled through measures to enhance maternal comfort, increased awareness of malposition and the role of posture, and the involvement of partners during trial counselling and recruitment.

Keywords: pregnant women, labour, presentation, posture, randomized controlled trial, survey

Procedia PDF Downloads 148
5 Malposition of Femoral Component in Total Hip Arthroplasty

Authors: Renate Krassnig, Gloria M. Hohenberger, Uldis Berzins, Stefen Fischerauer

Abstract:

Background: Only a few reports discuss the effectiveness of intraoperative radiographs for placing femoral components. Therefore there is no international standard in using intraoperative imaging in the proceeding of total hip replacement. Method: Case report; an 84-year-old female patient underwent changing the components of the Total hip arthroplasty (THA) because of aseptic loosening. Due to circumstances, the surgeon decided to implant a cemented femoral component. The procedure was without any significant abnormalities. The first postoperative radiograph was planned after recovery – as usual. The x-ray imaging showed a misplaced femoral component. Therefore a CT-scan was performed additionally and the malposition of the cemented femoral component was confirmed. The patient had to undergo another surgery – removing of the cemented femoral component and implantation of a new well placed one. Conclusion: Intraoperative imaging of the femoral component is not a common standard but this case shows that intraoperative imaging is a useful method for detecting errors and gives the surgeon the opportunity to correct errors intraoperatively.

Keywords: femoral component, intraoperative imaging, malplacement, revison

Procedia PDF Downloads 185
4 The Success Rate of Anterior Crowding Orthodontic Treatment Using Removable Appliances

Authors: Belly Yordan

Abstract:

Orthodontic treatment can be done by using the fix and removable orthodontic appliance. The success of treatment depends on the patient’s age, the type of malocclusion, treatment of space discrepancy, patient’s oral hygiene, operator skills, and patient cooperation. This case report was aimed to show the success of orthodontic treatment in patients with skeletal class I relationship, class I angle dental malocclusion with anterior crowding and rotation by using a removable appliance with modification. The removable appliance used is standard with removable plate components such as passive clasp (Adam’s hook clasp) accompanied with some active clasps (labial bow, some springs, etc.). A button is used as an additional tool or combined with other tools to correct tooth in rotated position. The results obtained by the success of treatments which is shown in pre and post-treatment photos, the overjet was reduced, the arch form became normal, the tooth malposition became normal, and rotation was corrected. Facial profile appearance of the patient is getting better, and the dental coordination also became better. This case report is to prove that treatment with the removable appliance is quite successful with the robust wearing of appropriate retainers.

Keywords: success rate, anterior crowding, orthodontic treatment, removable appliances

Procedia PDF Downloads 156
3 A Simple Technique for Centralisation of Distal Femoral Nail to Avoid Anterior Femoral Impingement and Perforation

Authors: P. Panwalkar, K. Veravalli, M. Tofighi, A. Mofidi

Abstract:

Introduction: Anterior femoral perforation or distal anterior nail position is a known complication of femoral nailing specifically in pertrochantric fractures fixed with cephalomedullary nail. This has been attributed to wrong entry point for the femoral nail, nail with large radius of curvature or malreduced fracture. Left alone anterior perforation of femur or abutment of nail on anterior femur will result in pain and risk stress riser at distal femur and periprosthetic fracture. There have been multiple techniques described to avert or correct this problem ranging from using different nail, entry point change, poller screw to deflect the nail position, use of shorter nail or use of curved guidewire or change of nail to ensure a nail with large radius of curvature Methods: We present this technique which we have used in order to centralise the femoral nail either when the nail has been put anteriorly or when the guide wire has been inserted too anteriorly prior to the insertion of the nail. This technique requires the use of femoral reduction spool from the nailing set. This technique was used by eight trainees of different level of experience under supervision. Results: This technique was easily reproducible without any learning curve without a need for opening of fracture site or change in the entry point with three different femoral nailing sets in twenty-five cases. The process took less than 10 minutes even when revising a malpositioned femoral nail. Conclusion: Our technique of using femoral reduction spool is easily reproducible and repeatable technique for avoidance of non-centralised femoral nail insertion and distal anterior perforation of femoral nail.

Keywords: femoral fracture, nailing, malposition, surgery

Procedia PDF Downloads 121
2 Preoperative 3D Planning and Reconstruction of Mandibular Defects for Patients with Oral Cavity Tumors

Authors: Janis Zarins, Kristaps Blums, Oskars Radzins, Renars Deksnis, Atis Svare, Santa Salaka

Abstract:

Wide tumor resection remains the first choice method for tumors of the oral cavity. Nevertheless, remained tissue defect impacts patients functional and aesthetical outcome, which could be improved using microvascular tissue transfers. Mandibular reconstruction is challenging due to the complexity of composite tissue defects and occlusal relationships for normal eating, chewing, and pain free jaw motions. Individual 3-D virtual planning would provide better symmetry and functional outcome. The main goal of preoperative planning is to develop a customized surgical approach with patient specific cutting guides of the mandible, osteotomy guides of the fibula, pre-bended osteosynthesis plates to perform more precise reconstruction, to decrease the surgery time and reach the best outcome. Our study is based on the analysis of 32 patients operated on between 2019 to 2021. All patients underwent mandible reconstruction with vascularized fibula flaps. Patients characteristics, surgery profile, survival, functional outcome, and quality of life was evaluated. Preoperative planning provided a significant decrease of surgery time and the best arrangement of bone closely similar as before the surgery. In cases of bone asymmetry, deformity and malposition, a new mandible was created using 3D planning to restore the appearance of lower jaw anatomy and functionality.

Keywords: mandibular, 3D planning, cutting guides, fibula flap, reconstruction

Procedia PDF Downloads 110
1 Uterine Torsion: A Rare Differential Diagnosis for Acute Abdominal Pain in Pregnancy

Authors: Tin Yee Ling, Kavita Maravar, Ruzica Ardalic

Abstract:

Background: Uterine torsion (UT) in pregnancy of more than 45-degree along the longitudinal axis is a rare occurrence, and the aetiology remains unclear. Case: A 34-year-old G2P1 woman with a history of one previous caesarean section presented at 36+2 weeks with sudden onset lower abdominal pain, syncopal episode, and tender abdomen on examination. She was otherwise haemodynamically stable. Cardiotocography showed a pathological trace with initial prolonged bradycardia followed by a subsequent tachycardia with reduced variability. An initial diagnosis of uterine dehiscence was made, given the history and clinical presentation. She underwent an emergency caesarean section which revealed a 180-degree UT along the longitudinal axis, with oedematous left round ligament lying transverse anterior to the uterus and a segment of large bowel inferior to the round ligament. Detorsion of uterus was performed prior to delivery of the foetus, and anterior uterine wall was intact with no signs of rupture. There were no anatomical uterine abnormalities found other than stretched left ovarian and round ligaments, which were repaired. Delivery was otherwise uneventful, and she was discharged on day 2 postpartum. Discussion: UT is rare as the number of reported cases is within the few hundreds worldwide. Generally, the uterus is supported in place by uterine ligaments, which limit the mobility of the structure. The causes of UT are unknown, but risk factors such as uterine abnormalities, increased uterine ligaments’ flexibility in pregnancy, and foetal malposition has been identified. UT causes occlusion of uterine vessels, which can lead to ischaemic injury of the placenta causing premature separation of the placenta, preterm labour, and foetal morbidity and mortality if delivery is delayed. Diagnosing UT clinically is difficult as most women present with symptoms similar to placenta abruption or uterine rupture (abdominal pain, vaginal bleeding, shock), and one-third are asymptomatic. The management of UT involves surgical detorsion of the uterus and delivery of foetus via caesarean section. Extra vigilance should be taken to identify the anatomy of the uterus experiencing torsion prior to hysterotomy. There have been a few cases reported with hysterotomy on posterior uterine wall for delivery of foetus as it may be difficult to identify and reverse a gravid UT when foetal well-being is at stake. Conclusion: UT should be considered a differential diagnosis of acute abdominal pain in pregnancy. It is crucial that the torsion is addressed immediately as it is associated with maternal and foetal morbidity and mortality.

Keywords: uterine torsion, pregnancy complication, abdominal pain, torted uterus

Procedia PDF Downloads 139