Search results for: TIVA
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4

Search results for: TIVA

4 Effects on Inflammatory Biomarkers and Respiratory Mechanics in Laparoscopic Bariatric Surgery: Desflurane vs. Total Intravenous Anaesthesia with Propofol

Authors: L. Kashyap, S. Jha, D. Shende, V. K. Mohan, P. Khanna, A. Aravindan, S. Kashyap, L. Singh, S. Aggarwal

Abstract:

Obesity is associated with a chronic inflammatory state. During surgery, there is an interplay between anaesthetic and surgical stress vis-a-vis the already present complex immune state. Moreover, the postoperative period is dictated by inflammation, which is crucial for wound healing and regeneration. An excess of inflammatory response might hamper recovery besides increasing the risk for infection and complications. There is definite evidence of the immunosuppressive role of inhaled anaesthetic agents. This immune modulation may be brought into effect directly by influencing the innate and adaptive immunity cells. The effects of propofol on immune mechanisms in has been widely elucidated because of its popularity. It reduces superoxide generation, elastase release, and chemotaxis. However, there is no unequivocal proof of one’s superiority over the other. Hence, an anaesthetic regimen with lesser inflammatory potential and specific to the obese patient is needed. OBESITA trial protocol (2019) by Sousa and co-workers in progress aims to test the hypothesis that anaesthesia with sevoflurane results in a weaker proinflammatory response compared to propofol, as evidenced by lower IL-6 and other biomarkers and an increased macrophage differentiation into M2 phenotype in adipose tissue. IL-6 was used as the objective parameter to evaluate inflammation as it is regulated by both surgery and anesthesia. It is the most sensitive marker of the inflammatory response to tissue damage since it is released within minutes by blood leukocytes. We hypothesized that maintenance of anaesthesia with propofol would lead to less inflammation than that with desflurane. Aims: The effect of two anaesthetic techniques, total intravenous anaesthesia (TIVA) with propofol and desflurane, on surgical stress response was evaluated. The primary objective was to compare serum interleukin-6 (IL-6) levels before and after surgery. Methods: In this prospective single-blinded randomized controlled trial undertaken, 30 obese patients (BMI>30 kg/m2) undergoing laparoscopic bariatric surgery under general anaesthesia were recruited. Patients were randomized to receive desflurane or TIVA using a target-controlled infusion for maintenance of anaesthesia. As a marker of inflammation, pre-and post-surgery IL-6 levels were compared. Results: After surgery, IL-6 levels increased significantly in both groups. The rise in IL-6 was less with TIVA than with desflurane; however, it did not reach significance. IL-6 rise post-surgery correlated positively with the complexity of procedure and duration of surgery and anaesthesia, rather than anaesthetic technique. Both groups did not differ in terms of intra-operative hemodynamic and respiratory variables, time to awakening, postoperative pulmonary complications, and duration of hospital stay. The incidence of nausea was significantly higher with desflurane than with TIVA. Conclusion: Inflammatory response did not differ as a function of anaesthetic technique when propofol and desflurane were compared. Also, patient and surgical variables dictated post-operative inflammation more than the anaesthetic factors. Further, larger sample size is needed to confirm or refute these findings.

Keywords: bariatric, biomarkers, inflammation, laparoscopy

Procedia PDF Downloads 94
3 Investigation on Morphologies, Forming Mechanism, Photocatalytic and Electronic Properties of Co-Zn Ferrite Nanostructure Grown on the Reduced Graphene Oxide Support

Authors: Qinglei Liu, Ali Charkhesht, Tiva Sharifi, Ashkan Bahadoran

Abstract:

Graphene sheets are promising nanoscale building blocks as a support material for the dispersion of nanoparticles. In this work, a solvothermal method employed to directly grow Co1-xZnxFe2O4 ferrite nanospheres on graphene oxide support that is subsequently reduced to graphene. The samples morphology, structure and crystallography were investigated using field-emission scanning electron microscopy (FE-SEM) and powder X-ray diffraction (XRD). The influences of the Zn2+ content on photocatalytic activity, electrical conductivity and magnetic property of the samples are also investigated. The results showed that Co1-x Znx Fe2 O4 nanoparticles are dispersed on graphene sheets and obtained nanocomposites are soft magnetic materials. In addition the samples showed excellent photocatalytic activity under visible light irradiation.

Keywords: reduced graphene oxide, ferrite, magnetic nanocomposite, photocatalytic activity, solvothermal method

Procedia PDF Downloads 218
2 Comparison of the Postoperative Analgesic Effects of Morphine, Paracetamol, and Ketorolac in Patient-Controlled Analgesia in the Patients Undergoing Open Cholecystectomy

Authors: Siamak Yaghoubi, Vahideh Rashtchi, Marzieh Khezri, Hamid Kayalha, Monadi Hamidfar

Abstract:

Background and objectives: Effective postoperative pain management in abdominal surgeries, which are painful procedures, plays an important role in reducing postoperative complications and increasing patient’s satisfaction. There are many techniques for pain control, one of which is Patient-Controlled Analgesia (PCA). The aim of this study was to compare the analgesic effects of morphine, paracetamol and ketorolac in the patients undergoing open cholecystectomy, using PCA method. Material and Methods: This randomized controlled trial was performed on 330 ASA (American Society of Anesthesiology) I-II patients ( three equal groups, n=110) who were scheduled for elective open cholecystectomy in Shahid Rjaee hospital of Qazvin, Iran from August 2013 until September 2015. All patients were managed by general anesthesia with TIVA (Total Intra Venous Anesthesia) technique. The control group received morphine with maximum dose of 0.02mg/kg/h, the paracetamol group received paracetamol with maximum dose of 1mg/kg/h, and the ketorolac group received ketorolac with maximum daily dose of 60mg using IV-PCA method. The parameters of pain, nausea, hemodynamic variables (BP and HR), pruritus, arterial oxygen desaturation, patient’s satisfaction and pain score were measured every two hours for 8 hours following operation in all groups. Results: There were no significant differences in demographic data between the three groups. there was a statistically significant difference with regard to the mean pain score at all times between morphine and paracetamol, morphine and ketorolac, and paracetamol and ketorolac groups (P<0.001). Results indicated a reduction with time in the mean level of postoperative pain in all three groups. At all times the mean level of pain in ketorolac group was less than that in the other two groups (p<0.001). Conclusion: According to the results of this study ketorolac is more effective than morphine and paracetamol in postoperative pain control in the patients undergoing open cholecystectomy, using PCA method.

Keywords: analgesia, cholecystectomy, ketorolac, morphine, paracetamol

Procedia PDF Downloads 169
1 Performance Validation of Model Predictive Control for Electrical Power Converters of a Grid Integrated Oscillating Water Column

Authors: G. Rajapakse, S. Jayasinghe, A. Fleming

Abstract:

This paper aims to experimentally validate the control strategy used for electrical power converters in grid integrated oscillating water column (OWC) wave energy converter (WEC). The particular OWC’s unidirectional air turbine-generator output power results in discrete large power pulses. Therefore, the system requires power conditioning prior to integrating to the grid. This is achieved by using a back to back power converter with an energy storage system. A Li-Ion battery energy storage is connected to the dc-link of the back-to-back converter using a bidirectional dc-dc converter. This arrangement decouples the system dynamics and mitigates the mismatch between supply and demand powers. All three electrical power converters used in the arrangement are controlled using finite control set-model predictive control (FCS-MPC) strategy. The rectifier controller is to regulate the speed of the turbine at a set rotational speed to uphold the air turbine at a desirable speed range under varying wave conditions. The inverter controller is to maintain the output power to the grid adhering to grid codes. The dc-dc bidirectional converter controller is to set the dc-link voltage at its reference value. The software modeling of the OWC system and FCS-MPC is carried out in the MATLAB/Simulink software using actual data and parameters obtained from a prototype unidirectional air-turbine OWC developed at Australian Maritime College (AMC). The hardware development and experimental validations are being carried out at AMC Electronic laboratory. The designed FCS-MPC for the power converters are separately coded in Code Composer Studio V8 and downloaded into separate Texas Instrument’s TIVA C Series EK-TM4C123GXL Launchpad Evaluation Boards with TM4C123GH6PMI microcontrollers (real-time control processors). Each microcontroller is used to drive 2kW 3-phase STEVAL-IHM028V2 evaluation board with an intelligent power module (STGIPS20C60). The power module consists of a 3-phase inverter bridge with 600V insulated gate bipolar transistors. Delta standard (ASDA-B2 series) servo drive/motor coupled to a 2kW permanent magnet synchronous generator is served as the turbine-generator. This lab-scale setup is used to obtain experimental results. The validation of the FCS-MPC is done by comparing these experimental results to the results obtained by MATLAB/Simulink software results in similar scenarios. The results show that under the proposed control scheme, the regulated variables follow their references accurately. This research confirms that FCS-MPC fits well into the power converter control of the OWC-WEC system with a Li-Ion battery energy storage.

Keywords: dc-dc bidirectional converter, finite control set-model predictive control, Li-ion battery energy storage, oscillating water column, wave energy converter

Procedia PDF Downloads 82