Search results for: Sophie A. Cassidy
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 63

Search results for: Sophie A. Cassidy

3 Pre-conditioning and Hot Water Sanitization of Reverse Osmosis Membrane for Medical Water Production

Authors: Supriyo Das, Elbir Jove, Ajay Singh, Sophie Corbet, Noel Carr, Martin Deetz

Abstract:

Water is a critical commodity in the healthcare and medical field. The utility of medical-grade water spans from washing surgical equipment, drug preparation to the key element of life-saving therapy such as hydrotherapy and hemodialysis for patients. A properly treated medical water reduces the bioburden load and mitigates the risk of infection, ensuring patient safety. However, any compromised condition during the production of medical-grade water can create a favorable environment for microbial growth putting patient safety at high risk. Therefore, proper upstream treatment of the medical water is essential before its application in healthcare, pharma and medical space. Reverse Osmosis (RO) is one of the most preferred treatments within healthcare industries and is recommended by all International Pharmacopeias to achieve the quality level demanded by global regulatory bodies. The RO process can remove up to 99.5% of constituents from feed water sources, eliminating bacteria, proteins and particles sizes of 100 Dalton and above. The combination of RO with other downstream water treatment technologies such as Electrodeionization and Ultrafiltration meet the quality requirements of various pharmacopeia monographs to produce highly purified water or water for injection for medical use. In the reverse osmosis process, the water from a liquid with a high concentration of dissolved solids is forced to flow through an especially engineered semi-permeable membrane to the low concentration side, resulting in high-quality grade water. However, these specially engineered RO membranes need to be sanitized either chemically or at high temperatures at regular intervals to keep the bio-burden at the minimum required level. In this paper, we talk about Dupont´s FilmTec Heat Sanitizable Reverse Osmosis membrane (HSRO) for the production of medical-grade water. An HSRO element must be pre-conditioned prior to initial use by exposure to hot water (80°C-85°C) for its stable performance and to meet the manufacturer’s specifications. Without pre-conditioning, the membrane will show variations in feed pressure operations and salt rejection. The paper will discuss the critical variables of pre-conditioning steps that can affect the overall performance of the HSRO membrane and demonstrate the data to support the need for pre-conditioning of HSRO elements. Our preliminary data suggests that there can be up to 35 % reduction in flow due to initial heat treatment, which also positively affects the increase in salt rejection. The paper will go into detail about the fundamental understanding of the performance change of HSRO after the pre-conditioning step and its effect on the quality of medical water produced. The paper will also discuss another critical point, “regular hot water sanitization” of these HSRO membranes. Regular hot water sanitization (at 80°C-85°C) is necessary to keep the membrane bioburden free; however, it can negatively impact the performance of the membrane over time. We will demonstrate several data points on hot water sanitization using FilmTec HSRO elements and challenge its robustness to produce quality medical water. The last part of this paper will discuss the construction details of the FilmTec HSRO membrane and features that make it suitable to pre-condition and sanitize at high temperatures.

Keywords: heat sanitizable reverse osmosis, HSRO, medical water, hemodialysis water, water for Injection, pre-conditioning, heat sanitization

Procedia PDF Downloads 180
2 Developing and Testing a Questionnaire of Music Memorization and Practice

Authors: Diana Santiago, Tania Lisboa, Sophie Lee, Alexander P. Demos, Monica C. S. Vasconcelos

Abstract:

Memorization has long been recognized as an arduous and anxiety-evoking task for musicians, and yet, it is an essential aspect of performance. Research shows that musicians are often not taught how to memorize. While memorization and practice strategies of professionals have been studied, little research has been done to examine how student musicians learn to practice and memorize music in different cultural settings. We present the process of developing and testing a questionnaire of music memorization and musical practice for student musicians in the UK and Brazil. A survey was developed for a cross-cultural research project aiming at examining how young orchestral musicians (aged 7–18 years) in different learning environments and cultures engage in instrumental practice and memorization. The questionnaire development included members of a UK/US/Brazil research team of music educators and performance science researchers. A pool of items was developed for each aspect of practice and memorization identified, based on literature, personal experiences, and adapted from existing questionnaires. Item development took the varying levels of cognitive and social development of the target populations into consideration. It also considered the diverse target learning environments. Items were initially grouped in accordance with a single underlying construct/behavior. The questionnaire comprised three sections: a demographics section, a section on practice (containing 29 items), and a section on memorization (containing 40 items). Next, the response process was considered and a 5-point Likert scale ranging from ‘always’ to ‘never’ with a verbal label and an image assigned to each response option was selected, following effective questionnaire design for children and youths. Finally, a pilot study was conducted with young orchestral musicians from diverse learning environments in Brazil and the United Kingdom. Data collection took place in either one-to-one or group settings to facilitate the participants. Cognitive interviews were utilized to establish response process validity by confirming the readability and accurate comprehension of the questionnaire items or highlighting the need for item revision. Internal reliability was investigated by measuring the consistency of the item groups using the statistical test Cronbach’s alpha. The pilot study successfully relied on the questionnaire to generate data about the engagement of young musicians of different levels and instruments, across different learning and cultural environments, in instrumental practice and memorization. Interaction analysis of the cognitive interviews undertaken with these participants, however, exposed the fact that certain items, and the response scale, could be interpreted in multiple ways. The questionnaire text was, therefore, revised accordingly. The low Cronbach’s Alpha scores of many item groups indicated another issue with the original questionnaire: its low level of internal reliability. Several reasons for each poor reliability can be suggested, including the issues with item interpretation revealed through interaction analysis of the cognitive interviews, the small number of participants (34), and the elusive nature of the construct in question. The revised questionnaire measures 78 specific behaviors or opinions. It can be seen to provide an efficient means of gathering information about the engagement of young musicians in practice and memorization on a large scale.

Keywords: cross-cultural, memorization, practice, questionnaire, young musicians

Procedia PDF Downloads 101
1 Surface Sunctionalization Strategies for the Design of Thermoplastic Microfluidic Devices for New Analytical Diagnostics

Authors: Camille Perréard, Yoann Ladner, Fanny D'Orlyé, Stéphanie Descroix, Vélan Taniga, Anne Varenne, Cédric Guyon, Michael. Tatoulian, Frédéric Kanoufi, Cyrine Slim, Sophie Griveau, Fethi Bedioui

Abstract:

The development of micro total analysis systems is of major interest for contaminant and biomarker analysis. As a lab-on-chip integrates all steps of an analysis procedure in a single device, analysis can be performed in an automated format with reduced time and cost, while maintaining performances comparable to those of conventional chromatographic systems. Moreover, these miniaturized systems are either compatible with field work or glovebox manipulations. This work is aimed at developing an analytical microsystem for trace and ultra trace quantitation in complex matrices. The strategy consists in the integration of a sample pretreatment step within the lab-on-chip by a confinement zone where selective ligands are immobilized for target extraction and preconcentration. Aptamers were chosen as selective ligands, because of their high affinity for all types of targets (from small ions to viruses and cells) and their ease of synthesis and functionalization. This integrated target extraction and concentration step will be followed in the microdevice by an electrokinetic separation step and an on-line detection. Polymers consisting of cyclic olefin copolymer (COC) or fluoropolymer (Dyneon THV) were selected as they are easy to mold, transparent in UV-visible and have high resistance towards solvents and extreme pH conditions. However, because of their low chemical reactivity, surface treatments are necessary. For the design of this miniaturized diagnostics, we aimed at modifying the microfluidic system at two scales : (1) on the entire surface of the microsystem to control the surface hydrophobicity (so as to avoid any sample wall adsorption) and the fluid flows during electrokinetic separation, or (2) locally so as to immobilize selective ligands (aptamers) on restricted areas for target extraction and preconcentration. We developed different novel strategies for the surface functionalization of COC and Dyneon, based on plasma, chemical and /or electrochemical approaches. In a first approach, a plasma-induced immobilization of brominated derivatives was performed on the entire surface. Further substitution of the bromine by an azide functional group led to covalent immobilization of ligands through “click” chemistry reaction between azides and terminal alkynes. COC and Dyneon materials were characterized at each step of the surface functionalization procedure by various complementary techniques to evaluate the quality and homogeneity of the functionalization (contact angle, XPS, ATR). With the objective of local (micrometric scale) aptamer immobilization, we developed an original electrochemical strategy on engraved Dyneon THV microchannel. Through local electrochemical carbonization followed by adsorption of azide-bearing diazonium moieties and covalent linkage of alkyne-bearing aptamers through click chemistry reaction, typical dimensions of immobilization zones reached the 50 µm range. Other functionalization strategies, such as sol-gel encapsulation of aptamers, are currently investigated and may also be suitable for the development of the analytical microdevice. The development of these functionalization strategies is the first crucial step in the design of the entire microdevice. These strategies allow the grafting of a large number of molecules for the development of new analytical tools in various domains like environment or healthcare.

Keywords: alkyne-azide click chemistry (CuAAC), electrochemical modification, microsystem, plasma bromination, surface functionalization, thermoplastic polymers

Procedia PDF Downloads 414