8 Robustified Asymmetric Logistic Regression Model for Global Fish Stock Assessment
Authors: Osamu Komori, Shinto Eguchi, Hiroshi Okamura, Momoko Ichinokawa
Abstract:
The long time-series data on population assessments are essential for global ecosystem assessment because the temporal change of biomass in such a database reflects the status of global ecosystem properly. However, the available assessment data usually have limited sample sizes and the ratio of populations with low abundance of biomass (collapsed) to those with high abundance (non-collapsed) is highly imbalanced. To allow for the imbalance and uncertainty involved in the ecological data, we propose a binary regression model with mixed effects for inferring ecosystem status through an asymmetric logistic model. In the estimation equation, we observe that the weights for the non-collapsed populations are relatively reduced, which in turn puts more importance on the small number of observations of collapsed populations. Moreover, we extend the asymmetric logistic regression model using propensity score to allow for the sample biases observed in the labeled and unlabeled datasets. It robustified the estimation procedure and improved the model fitting.Keywords: double robust estimation, ecological binary data, mixed effect logistic regression model, propensity score
Procedia PDF Downloads 2687 The Interaction between Hydrogen and Surface Stress in Stainless Steel
Authors: Osamu Takakuwa, Yuta Mano, Hitoshi Soyama
Abstract:
This paper reveals the interaction between hydrogen and surface stress in austenitic stainless steel by X-ray diffraction stress measurement and thermal desorption analysis before and after being charged with hydrogen. The surface residual stress was varied by surface finishing using several disc polishing agents. The obtained results show that the residual stress near surface had a significant effect on hydrogen absorption behavior, that is, tensile residual stress promoted the hydrogen absorption and compressive one did opposite. Also, hydrogen induced equi-biaxial stress and this stress has a linear correlation with hydrogen content.Keywords: hydrogen embrittlement, residual stress, surface finishing, stainless steel
Procedia PDF Downloads 3816 Sewer Culvert Installation Method to Accommodate Underground Construction in an Urban Area with Narrow Streets
Authors: Osamu Igawa, Hiroshi Kouchiwa, Yuji Ito
Abstract:
In recent years, a reconstruction project for sewer pipelines has been progressing in Japan with the aim of renewing old sewer culverts. However, it is difficult to secure a sufficient base area for shafts in an urban area because many streets are narrow with a complex layout. As a result, construction in such urban areas is generally very demanding. In urban areas, there is a strong requirement for a safe, reliable and economical construction method that does not disturb the public’s daily life and urban activities. With this in mind, we developed a new construction method called the 'shield switching type micro-tunneling method' which integrates the micro-tunneling method and shield method. In this method, pipeline is constructed first for sections that are gently curved or straight using the economical micro-tunneling method, and then the method is switched to the shield method for sections with a sharp curve or a series of curves without establishing an intermediate shaft. This paper provides the information, features and construction examples of this newly developed method.Keywords: micro-tunneling method, secondary lining applied RC segment, sharp curve, shield method, switching type
Procedia PDF Downloads 4065 Effect of Drag Coefficient Models concerning Global Air-Sea Momentum Flux in Broad Wind Range including Extreme Wind Speeds
Authors: Takeshi Takemoto, Naoya Suzuki, Naohisa Takagaki, Satoru Komori, Masako Terui, George Truscott
Abstract:
Drag coefficient is an important parameter in order to correctly estimate the air-sea momentum flux. However, The parameterization of the drag coefficient hasn’t been established due to the variation in the field data. Instead, a number of drag coefficient model formulae have been proposed, even though almost all these models haven’t discussed the extreme wind speed range. With regards to such models, it is unclear how the drag coefficient changes in the extreme wind speed range as the wind speed increased. In this study, we investigated the effect of the drag coefficient models concerning the air-sea momentum flux in the extreme wind range on a global scale, comparing two different drag coefficient models. Interestingly, one model didn’t discuss the extreme wind speed range while the other model considered it. We found that the difference of the models in the annual global air-sea momentum flux was small because the occurrence frequency of strong wind was approximately 1% with a wind speed of 20m/s or more. However, we also discovered that the difference of the models was shown in the middle latitude where the annual mean air-sea momentum flux was large and the occurrence frequency of strong wind was high. In addition, the estimated data showed that the difference of the models in the drag coefficient was large in the extreme wind speed range and that the largest difference became 23% with a wind speed of 35m/s or more. These results clearly show that the difference of the two models concerning the drag coefficient has a significant impact on the estimation of a regional air-sea momentum flux in an extreme wind speed range such as that seen in a tropical cyclone environment. Furthermore, we estimated each air-sea momentum flux using several kinds of drag coefficient models. We will also provide data from an observation tower and result from CFD (Computational Fluid Dynamics) concerning the influence of wind flow at and around the place.Keywords: air-sea interaction, drag coefficient, air-sea momentum flux, CFD (Computational Fluid Dynamics)
Procedia PDF Downloads 3724 Examining the Adoption Rate of the Japanese Method of Food Samples in the International Market
Authors: Marwa Abdulsalam, Osamu Suzuki, Wirawan Dony Dahana
Abstract:
One of the remarkable and unique industries in Japan is the food samples industry which can be noticed in most of the restaurants located around Japan. However, the market is getting saturated, which has pushed Japanese food sample manufacturers to start exploring new international markets. Most of the markets they explored were in the East Asian region, such as China or Korea. In this research, we examine the feasibility and the potential adoption rate of food samples in the international market outside the East Asian region. The main focus of this study is on the Saudi Arabian market. Nonetheless, since Saudi Arabia is a big market, the study results could possibly be applied to the international market as well. The study has conducted a quantitative survey to test the potential of the food samples industry in Saudi Arabia especially in 4 major cities: Jeddah, Mecca, Riyadh, and Dammam. The survey also tests the willingness to purchase, the average price point that the consumer is willing to pay for food samples, and the factors that drive restaurant owners to adopt the food samples system. The study created a correlation analysis between different factors, such as the geographic factor and the size of the restaurant factor, to examine the effect of different aspects on the purchasing decision. The study has found that the Japanese food samples system is predicted to adapt successfully in the Saudi Arabian market and in the international market alike due to the high importance of the food culture and the existence of the communication challenges that the food samples can solve. Additionally, the market survey stated in this study indicated that 83% of the restaurants’ managers are willing to adopt this system in their restaurants.Keywords: food samples, innovative marketing, international market, marketing method
Procedia PDF Downloads 1103 Analysis of Adipose Tissue-Derived Mesenchymal Stem Cells under Atherosclerosis Microenvironment
Authors: Do Khanh Vy, Vuong Cat Khanh, Osamu Ohneda
Abstract:
During atherosclerosis (AS) progression, perivascular adipose tissue-derived mesenchymal stem cells (PVAT-MSCs) are exposed to the hypoxic environment due to the oxygenic deprivation which might influence the adipose tissue-derived mesenchymal stem cells (AT-MSCs) function. Additionally, it has been reported that the angiogenic ability of subcutaneous AT-MSCs (SAT-MSCs) was impaired in the AS patients. However, up to now, the effects of AS on the characteristics and function of PVAT-MSCs have not been clarified yet. In the present study, we analyzed the AS microenvironment effects on the characteristics and function of AT-MSCs. We found that there was no significant difference in cellular morphology and differentiation ability between SAT-MSCs and PVAT-MSCs in AS patients. However, the proliferation of AS-derived PVAT-MSCs was less than those of AS-derived SAT-MSCs. Importantly, the migration of AS-derived PVAT-MSCs was faster than AS-derived SAT-MSCs. Of note, AS-derived PVAT-MSCs showed the upregulation of SDF1, which is related to the homing, and VEGF, which is related to the angiogenesis compared to those of AS-derived SAT-MSCs. Consistent with these results, AS-derived PVAT-MSCs showed the higher ability to recruit EPCs and ECs than AS-derived SAT-MSCs. In addition, EPCs and ECs which cultured in the presence of AS-derived PVAT-MSC conditioned medium showed the higher angiogenic function of the tube formation compared to those cultured in AS-derived SAT-MSC conditioned medium. This result suggests that the higher paracrine effects of AS-derived PVAT-MSCs support the angiogenic function of the target cells. Our data showed the different characteristics and functions of AT-MSCs derived from different sources of tissues. Under the AS microenvironment, it seems that the characteristics and functions of PVAT-MSCs might reflect the progression of AS. Further study will be necessary to clarify the mechanism in the future.Keywords: atherosclerosis, mesenchymal stem cells, perivascular adipose tissue, subcutaneous adipose tissue
Procedia PDF Downloads 1622 Modification of Magneto-Transport Properties of Ferrimagnetic Mn₄N Thin Films by Ni Substitution and Their Magnetic Compensation
Authors: Taro Komori, Toshiki Gushi, Akihito Anzai, Taku Hirose, Kaoru Toko, Shinji Isogami, Takashi Suemasu
Abstract:
Ferrimagnetic antiperovskite Mn₄₋ₓNiₓN thin film exhibits both small saturation magnetization and rather large perpendicular magnetic anisotropy (PMA) when x is small. Both of them are suitable features for application to current induced domain wall motion devices using spin transfer torque (STT). In this work, we successfully grew antiperovskite 30-nm-thick Mn₄₋ₓNiₓN epitaxial thin films on MgO(001) and STO(001) substrates by MBE in order to investigate their crystalline qualities and magnetic and magneto-transport properties. Crystalline qualities were investigated by X-ray diffraction (XRD). The magnetic properties were measured by vibrating sample magnetometer (VSM) at room temperature. Anomalous Hall effect was measured by physical properties measurement system. Both measurements were performed at room temperature. Temperature dependence of magnetization was measured by VSM-Superconducting quantum interference device. XRD patterns indicate epitaxial growth of Mn₄₋ₓNiₓN thin films on both substrates, ones on STO(001) especially have higher c-axis orientation thanks to greater lattice matching. According to VSM measurement, PMA was observed in Mn₄₋ₓNiₓN on MgO(001) when x ≤ 0.25 and on STO(001) when x ≤ 0.5, and MS decreased drastically with x. For example, MS of Mn₃.₉Ni₀.₁N on STO(001) was 47.4 emu/cm³. From the anomalous Hall resistivity (ρAH) of Mn₄₋ₓNiₓN thin films on STO(001) with the magnetic field perpendicular to the plane, we found out Mr/MS was about 1 when x ≤ 0.25, which suggests large magnetic domains in samples and suitable features for DW motion device application. In contrast, such square curves were not observed for Mn₄₋ₓNiₓN on MgO(001), which we attribute to difference in lattice matching. Furthermore, it’s notable that although the sign of ρAH was negative when x = 0 and 0.1, it reversed positive when x = 0.25 and 0.5. The similar reversal occurred for temperature dependence of magnetization. The magnetization of Mn₄₋ₓNiₓN on STO(001) increases with decreasing temperature when x = 0 and 0.1, while it decreases when x = 0.25. We considered that these reversals were caused by magnetic compensation which occurred in Mn₄₋ₓNiₓN between x = 0.1 and 0.25. We expect Mn atoms of Mn₄₋ₓNiₓN crystal have larger magnetic moments than Ni atoms do. The temperature dependence stated above can be explained if we assume that Ni atoms preferentially occupy the corner sites, and their magnetic moments have different temperature dependence from Mn atoms at the face-centered sites. At the compensation point, Mn₄₋ₓNiₓN is expected to show very efficient STT and ultrafast DW motion with small current density. What’s more, if angular momentum compensation is found, the efficiency will be best optimized. In order to prove the magnetic compensation, X-ray magnetic circular dichroism will be performed. Energy dispersive X-ray spectrometry is a candidate method to analyze the accurate composition ratio of samples.Keywords: compensation, ferrimagnetism, Mn₄N, PMA
Procedia PDF Downloads 1351 Nondestructive Electrochemical Testing Method for Prestressed Concrete Structures
Authors: Tomoko Fukuyama, Osamu Senbu
Abstract:
Prestressed concrete is used a lot in infrastructures such as roads or bridges. However, poor grout filling and PC steel corrosion are currently major issues of prestressed concrete structures. One of the problems with nondestructive corrosion detection of PC steel is a plastic pipe which covers PC steel. The insulative property of pipe makes a nondestructive diagnosis difficult; therefore a practical technology to detect these defects is necessary for the maintenance of infrastructures. The goal of the research is a development of an electrochemical technique which enables to detect internal defects from the surface of prestressed concrete nondestructively. Ideally, the measurements should be conducted from the surface of structural members to diagnose non-destructively. In the present experiment, a prestressed concrete member is simplified as a layered specimen to simulate a current path between an input and an output electrode on a member surface. The specimens which are layered by mortar and the prestressed concrete constitution materials (steel, polyethylene, stainless steel, or galvanized steel plates) were provided to the alternating current impedance measurement. The magnitude of an applied electric field was 0.01-volt or 1-volt, and the frequency range was from 106 Hz to 10-2 Hz. The frequency spectrums of impedance, which relate to charge reactions activated by an electric field, were measured to clarify the effects of the material configurations or the properties. In the civil engineering field, the Nyquist diagram is popular to analyze impedance and it is a good way to grasp electric relaxation using a shape of the plot. However, it is slightly not suitable to figure out an influence of a measurement frequency which is reciprocal of reaction time. Hence, Bode diagram is also applied to describe charge reactions in the present paper. From the experiment results, the alternating current impedance method looks to be applicable to the insulative material measurement and eventually prestressed concrete diagnosis. At the same time, the frequency spectrums of impedance show the difference of the material configuration. This is because the charge mobility reflects the variety of substances and also the measuring frequency of the electric field determines migration length of charges which are under the influence of the electric field. However, it could not distinguish the differences of the material thickness and is inferred the difficulties of prestressed concrete diagnosis to identify the amount of an air void or a layer of corrosion product by the technique.Keywords: capacitance, conductance, prestressed concrete, susceptance
Procedia PDF Downloads 413