Chrysanthemum herbs (Asteraceae) are extensively used as food additives and in folk medicine. Anti-cancer, anti-human immunodeficiency virus type 1 (HIV-1), anti-inflammatory, antinociceptive and antiproliferative activities as well as antioxidant effects have been reported for Chrysanthemum species. We report the isolation and identification of flavonoids and new and known terpenoids from the endemic species, C. macrocarpum and C. deserticolum “guertoufa”, used in Algerian Sahara as tea drinks and in “couscous” and soups “Chorba”. Structures of the isolated compounds were established by 1-D and 2-D homo and hetero-nuclear NMR (1H, 13C, COSY, HSQC, HMBC, and NOESY), mass spectrometry, UV and comparison with literature data. C. deserticolum extracts were tested by four methods to identify the antioxidant activity namely, ABTS•+, DPPH• scavenging, CUPRAC and ferrous-ions chelating activity methods. Anti-inflammatory, antinociceptive, antiproliferative and antioxidant activities of C. macrocarpum extracts and isolated compounds are also reported here.

Keywords: Chrysanthemum macrocarpum, C. deserticolum, flavonoids, terpenoids, antioxidant, anti-inflammatory, anti-proliferative

Procedia PDF Downloads 300
1 The Effect of the Acquisition and Reconstruction Parameters in Quality of Spect Tomographic Images with Attenuation and Scatter Correction

Authors: N. Boutaghane, F. Z. Tounsi

Abstract:

Many physical and technological factors degrade the SPECT images, both qualitatively and quantitatively. For this, it is not always put into leading technological advances to improve the performance of tomographic gamma camera in terms of detection, collimation, reconstruction and correction of tomographic images methods. We have to master firstly the choice of various acquisition and reconstruction parameters, accessible to clinical cases and using the attenuation and scatter correction methods to always optimize quality image and minimized to the maximum dose received by the patient. In this work, an evaluation of qualitative and quantitative tomographic images is performed based on the acquisition parameters (counts per projection) and reconstruction parameters (filter type, associated cutoff frequency). In addition, methods for correcting physical effects such as attenuation and scatter degrading the image quality and preventing precise quantitative of the reconstructed slices are also presented. Two approaches of attenuation and scatter correction are implemented: the attenuation correction by CHANG method with a filtered back projection reconstruction algorithm and scatter correction by the subtraction JASZCZAK method. Our results are considered as such recommandation, which permits to determine the origin of the different artifacts observed both in quality control tests and in clinical images.

Keywords: attenuation, scatter, reconstruction filter, image quality, acquisition and reconstruction parameters, SPECT