Search results for: Gokhan Uysal
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 63

Search results for: Gokhan Uysal

3 A Diagnostic Accuracy Study: Comparison of Two Different Molecular-Based Tests (Genotype HelicoDR and Seeplex Clar-H. pylori ACE Detection), in the Diagnosis of Helicobacter pylori Infections

Authors: Recep Kesli, Huseyin Bilgin, Yasar Unlu, Gokhan Gungor

Abstract:

Aim: The aim of this study was to compare diagnostic values of two different molecular-based tests (GenoType® HelicoDR ve Seeplex® H. pylori-ClaR- ACE Detection) in detection presence of the H. pylori from gastric biopsy specimens. In addition to this also was aimed to determine resistance ratios of H. pylori strains against to clarytromycine and quinolone isolated from gastric biopsy material cultures by using both the genotypic (GenoType® HelicoDR, Seeplex ® H. pylori -ClaR- ACE Detection) and phenotypic (gradient strip, E-test) methods. Material and methods: A total of 266 patients who admitted to Konya Education and Research Hospital Department of Gastroenterology with dyspeptic complaints, between January 2011-June 2013, were included in the study. Microbiological and histopathological examinations of biopsy specimens taken from antrum and corpus regions were performed. The presence of H. pylori in all the biopsy samples was investigated by five differnt dignostic methods together: culture (C) (Portagerm pylori-PORT PYL, Pylori agar-PYL, GENbox microaer, bioMerieux, France), histology (H) (Giemsa, Hematoxylin and Eosin staining), rapid urease test (RUT) (CLOtest, Cimberly-Clark, USA), and two different molecular tests; GenoType® HelicoDR, Hain, Germany, based on DNA strip assay, and Seeplex ® H. pylori -ClaR- ACE Detection, Seegene, South Korea, based on multiplex PCR. Antimicrobial resistance of H. pylori isolates against clarithromycin and levofloxacin was determined by GenoType® HelicoDR, Seeplex ® H. pylori -ClaR- ACE Detection, and gradient strip (E-test, bioMerieux, France) methods. Culture positivity alone or positivities of both histology and RUT together was accepted as the gold standard for H. pylori positivity. Sensitivity and specificity rates of two molecular methods used in the study were calculated by taking the two gold standards previously mentioned. Results: A total of 266 patients between 16-83 years old who 144 (54.1 %) were female, 122 (45.9 %) were male were included in the study. 144 patients were found as culture positive, and 157 were H and RUT were positive together. 179 patients were found as positive with GenoType® HelicoDR and Seeplex ® H. pylori -ClaR- ACE Detection together. Sensitivity and specificity rates of studied five different methods were found as follows: C were 80.9 % and 84.4 %, H + RUT were 88.2 % and 75.4 %, GenoType® HelicoDR were 100 % and 71.3 %, and Seeplex ® H. pylori -ClaR- ACE Detection were, 100 % and 71.3 %. A strong correlation was found between C and H+RUT, C and GenoType® HelicoDR, and C and Seeplex ® H. pylori -ClaR- ACE Detection (r:0.644 and p:0.000, r:0.757 and p:0.000, r:0.757 and p:0.000, respectively). Of all the isolated 144 H. pylori strains 24 (16.6 %) were detected as resistant to claritromycine, and 18 (12.5 %) were levofloxacin. Genotypic claritromycine resistance was detected only in 15 cases with GenoType® HelicoDR, and 6 cases with Seeplex ® H. pylori -ClaR- ACE Detection. Conclusion: In our study, it was concluded that; GenoType® HelicoDR and Seeplex ® H. pylori -ClaR- ACE Detection was found as the most sensitive diagnostic methods when comparing all the investigated other ones (C, H, and RUT).

Keywords: Helicobacter pylori, GenoType® HelicoDR, Seeplex ® H. pylori -ClaR- ACE Detection, antimicrobial resistance

Procedia PDF Downloads 135
2 The Investigation of Niobium Addition on Mechanical Properties of Al11Si alloy

Authors: Kerem Can Dizdar, Semih Ateş, Ozan Güler, Gökhan Basman, Derya Dışpınar, Cevat Fahir Arısoy

Abstract:

Grain refinement and obtaining homogeneous microstructure is the key parameter in casting of aluminum alloys. Ti has been traditionally used as grain refiner, however, inconsistency and heterogeneous dendrite arms, as well as fading efficiency, have been the drawbacks of Ti. Alternatively, Nb (Niobium) has gained attention. In this work, the effect of Nb was investigated in case of both as cast and T6 heat treated conditions. Different ratios of Nb (0.0, 0.03, 0.05, 0.07, 0.1 weight%) were added to AlSi11 alloy, mechanical properties were examined statistically, and relationship was established between microstructure and mechanical properties by examining the grain size and dendrite characteristics before and after heat treatment. Results indicate that in the case of as cast state; with the increasing addition of Nb has no significant effect on yield strength, however, it increases the tensile strength and elongation starting with 0.05wt% ratio, and it remains constant up to 0.1wt%. For the heat-treated condition; Nb addition provides increment at yield strength and tensile strength up to 0.05wt%, but it leads to decrementfrom 0.05 to 0.1wt%. The opposite is valid for the elongation; It decreases in between 0-0.05wt% then rises in range of 0.05-0.1wt%. Highest yield strength and ultimate tensile strength were found T6 heat treated 0.05wt% Nb addition. 0.05wt% was found as critical Nbaddition ratio for mechanical properties of Al-11Si alloys. Grain refinement and obtaining homogeneous microstructure is the key parameter in casting of aluminum alloys. Ti has been traditionally used as grain refiner, however, inconsistency and heterogeneous dendrite arms, as well as fading efficiency, have been the drawbacks of Ti. Alternatively, Nb (Niobium) has gained attention. In this work, the effect of Nb was investigated in case of both as cast and T6 heat treated conditions. Different ratios of Nb (0.0, 0.03, 0.05, 0.07, 0.1 weight%) were added to AlSi11 alloy, mechanical properties were examined statistically, and relationship was established between microstructure and mechanical properties by examining the grain size and dendrite characteristics before and after heat treatment. Results indicate that in the case of as cast state; with the increasing addition of Nb has no significant effect on yield strength, however, it increases the tensile strength and elongation starting with 0.05wt% ratio, and it remains constant up to 0.1wt%. For the heat-treated condition; Nb addition provides increment at yield strength and tensile strength up to 0.05wt%, but it leads to decrement from 0.05 to 0.1wt%. The opposite is valid for the elongation; It decreases in between 0-0.05wt% then rises in range of 0.05-0.1wt%. Highest yield strength and ultimate tensile strength were found T6 heat treated 0.05wt% Nb addition. 0.05wt% was found as critical Nbaddition ratio for mechanical properties of Al-11Si alloys.

Keywords: al-si alloy, grain refinement, heat treatment, mechanical properties, microstructure, niobium, sand casting

Procedia PDF Downloads 127
1 Estimating the Effect of a Newly Developed Portable Innovative Balance Room System with a Digital Game Program on Falls and Incontinence Symptoms in the Elderly

Authors: Özge Çeliker Tosun, Melda Başer Secer, İsmail Düşmez, Sedat Çapar, İlkay Kozak, Melahat Aktaş, Furkan Can Şimşek, Gökhan Tosun

Abstract:

Purpose: Portable innovative balance room system with digital game program; It was created to be able to be divided into small areas, such as inside the house, garden, balcony, to enable the person to enter and perform both evaluation and exercise safely, and to ensure that these results can be stored and sent to the therapist live or later when desired. The aim is to compare the effectiveness of the exercise program applied by the elderly within this system and the exercise program implemented under the supervision of a physiotherapist on balance and urinary incontinence symptoms. Materials and Methods: The study was conducted in a randomized controlled manner on 63 people with urinary incontinence (mean age: 75.5 years) at Narlıdere Nursing Home Elderly Care and Rehabilitation Center. Elderly people participating in the study were divided into 3 groups: 1. Group, an exercise program consisting of pelvic floor muscle training and OTOGA exercises, 2. Group, only pelvic floor muscle training, and 3. Group, pelvic floor muscle training and Otoga exercises in the form of a digital game program in a portable balance room system. (self-administered) for 12 weeks. Pelvic floor distress inventory (PTDE-20) and bladder diary were used to evaluate the incontinance symptoms of the cases. Pelvic floor muscle function was evaluated with superficial EMG. Berg, Fall Effectiveness Scale (FES) and Functional Status Evaluations (Chair Stand Test, Eight (8) Food Up and Go Test, Chair Sit and Reach Test, Two Minutes Step Test) were used to evaluate balance. The existence of differences between groups was analyzed using Krusskal Wallis analysis of variance, and the difference between before and after exercise was analyzed with Wilcoxon tests. Results: After treatment, PTDE-20, daily urinary incontinence and toilet visits values decreased significantly in all three groups (p < 0.001). While there was a statistically significant increase in pelvic floor muscle EMG values in the 2nd and third groups after treatment, there was no change in the other group (2nd Group PFM average EMG before-after: 5.5 (4.15-10.95) - 10.95 (8.68-13.68), P=0.05, 3 Group PFM average EMG before-after: 6.5 (4.28-11.55) - 11.75 (8.67-14.26), p=0.04). While BERG score, Chair Stand Test, Eight (8) Food Up and Go Test, and Two Minutes Step Test values increased in all groups (p<0.05), Fall Effectiveness Scale (FES) values did not change after treatment. Conclusion: Although pelvic floor muscle training combined with balance exercises reduces symptoms, it may not lead to a positive improvement in the functions of the pelvic floor muscles. For this reason, recovery lasts for a short time, and then symptoms may reoccur in the future. However, thanks to the new system, when balance exercises are combined with a game program for the pelvic floor muscles, a double effect can be achieved with a single application and both incontinence and balance problems can be treated in a safe environment where the person can do it himself. But more work needs to be done on this subject. However, thanks to the new system, a double effect can be achieved with a single application, and both incontinence and balance problems can be treated in a safe environment where the person can do it himself. But more work needs to be done on new system

Keywords: fall, urinary incontinance, balance, elderly

Procedia PDF Downloads 47