Search results for: Fricke dosimeter
10 Inhibition Theory: The Development of Subjective Happiness and Life Satisfaction After Experiencing Severe Traumatic Life Events (Paraplegia)
Authors: Tanja Ecken, Laura Fricke, Anika Wehling, Maren M. Michaelsen, Tobias Esch
Abstract:
Studies and applied experiences evidence severe and traumatic accidents not only require physical rehabilitation and recovery but also necessitate a psychological adaption and reorganization to the changed living conditions. Neurobiological models underpinning the experience of happiness and satisfaction postulate life shocks to potentially enhance the experience of happiness and life satisfaction, i.e., posttraumatic growth (PTG). This present study aims to provide an in-depth understanding of the underlying psychological processes of PTG and to outline its consequences on subjective happiness and life satisfaction. To explore the aforementioned, Esch’s ABC Model was used as guidance for the development of a questionnaire assessing changes in happiness and life satisfaction and for a schematic model postulating the development of PTG in the context of paraplegia. Two-stage qualitative interview procedures explored participants’ experiences of paraplegia. Specifically, narrative, semi-structured interviews (N=28) focused on the time before and after the accident, the availability of supportive resources, and potential changes in the perception of happiness and life satisfaction. Qualitative analysis (Grounded Theory) indicated an initial phase of reorganization was followed by a gradual psychological adaption to novel, albeit reduced, opportunities in life. Participants reportedly experienced a ‘compelled’ slowing down and elements of mindfulness, subsequently instilling a sense of gratitude and joy in relation to life’s presumed trivialities. Despite physical limitations and difficulties, participants reported an enhanced ability to relate to oneself and others and a reduction of perceived everyday nuisances. Concluding, PTG can be experienced in response to severe, traumatic life events and has the potential to enrich the lives of affected persons in numerous, unexpected and yet challenging ways. PTG appears to be a spectrum comprised of an interplay of internal and external resources underpinned by neurobiological processes. Participants experienced PTG irrelevant of age, gender, marital status, income or level of education.Keywords: post traumatic growth, happiness, life satisfaction, traumatic life events, paraplegia, ABC model, trauma
Procedia PDF Downloads 679 Inhibition Theory: The Development of Subjective Happiness and Life Satisfaction after Experiencing Severe, Traumatic Life Events (Paraplegia)
Authors: Tanja Ecken, Laura Fricke, Anika Steger, Maren M. Michaelsen, Tobias Esch
Abstract:
Studies and applied experiences evidence severe and traumatic accidents to not only require physical rehabilitation and recovery but also to necessitate a psychological adaption and reorganization to the changed living conditions. Neurobiological models underpinning the experience of happiness and satisfaction postulate life shocks to potentially enhance the experience of happiness and life satisfaction, i.e., posttraumatic growth (PTG). This present study aims to provide an in-depth understanding of the underlying psychological processes of PTG and to outline its consequences on subjective happiness and life satisfaction. To explore the aforementioned, Esch’s (2022) ABC Model was used as guidance for the development of a questionnaire assessing changes in happiness and life satisfaction and for a schematic model postulating the development of PTG in the context of paraplegia. Two-stage qualitative interview procedures explored participants’ experiences of paraplegia. Specifically, narrative, semi-structured interviews (N=28) focused on the time before and after the accident, the availability of supportive resources, and potential changes in the perception of happiness and life satisfaction. Qualitative analysis (Grounded Theory) indicated an initial phase of reorganization was followed by a gradual psychological adaption to novel, albeit reduced, opportunities in life. Participants reportedly experienced a ‘compelled’ slowing down and elements of mindfulness, subsequently instilling a sense of gratitude and joy in relation to life’s presumed trivialities. Despite physical limitations and difficulties, participants reported an enhanced ability to relate to oneself and others and a reduction of perceived every day nuisances. Concluding, PTG can be experienced in response to severe, traumatic life events and has the potential to enrich the lives of affected persons in numerous, unexpected and yet challenging ways. PTG appears to be spectrum comprised of an interplay of internal and external resources underpinned by neurobiological processes. Participants experienced PTG irrelevant of age, gender, marital status, income or level of education.Keywords: inhibition theory, posttraumatic growth, trauma, stress, life satisfaction, subjective happiness, traumatic life events, paraplegia
Procedia PDF Downloads 868 Seasonal Variation of the Unattached Fraction and Equilibrium Factor of ²²²Rn, ²²⁰Rn
Authors: Rajan Jakhu, Rohit Mehra
Abstract:
Radon (²²²Rn) and its decay products are the major sources of natural radiation exposure to general population. The activity concentrations of radon, thoron gasses, and their unattached and attached short-lived progeny in indoor environment of the Jaipur and Ajmer districts of Rajasthan had been calculated via passive measurements using the Pinhole cup dosimeter, deposition based progeny sensors (DRPS/DTPS) and wire mesh capped (DRPS/DTPS) progeny sensors. The results of this study revealed that radon and thoron concentrations (CRn, CTn) are highest in the winter season. The variation of the radon and its decay products are observed to vary seasonally, but these environmental parameters seem not to be affecting the thoron and its decay product concentrations in a regular manner. The average values of the radon and its decay products are maximum in winter and minimum in summer. The equilibrium factor for radon is observed to be 0.50, 0.47 and 0.49 in winter, rainy and summer seasons. The annual average value of the unattached fraction of the radon progeny comes out to be 0.34. On the other hand, the average value of thoron (²²⁰Rn) concentration and its equilibrium factor in the studied area comes to be 74, 39, 45 Bq m⁻³ and 0.07, 0.11, 0.07 respectively for the winter, rainy and summer seasons with the annual average value of the unattached fraction of about 0.18. The annual average radiological dose from exposure to indoor radon and thoron progeny comes out to be 0.88 and 0.78 mSv.Keywords: equilibrium factor, radon, seasonal variation, thoron, unattached fraction
Procedia PDF Downloads 3117 Thermoluminescent Response of Nanocrystalline BaSO4:Eu to 85 MeV Carbon Beams
Authors: Shaila Bahl, S. P. Lochab, Pratik Kumar
Abstract:
Nanotechnology and nanomaterials have attracted researchers from different fields, especially from the field of luminescence. Recent studies on various luminescent nanomaterials have shown their relevance in dosimetry of ionizing radiations for the measurements of high doses using the Thermoluminescence (TL) technique, where the conventional microcrystalline phosphors saturate. Ion beams have been used for diagnostic and therapeutic purposes due to their favorable profile of dose deposition at the end of the range known as the Bragg peak. While dealing with human beings, doses from these beams need to be measured with great precision and accuracy. Henceforth detailed investigations of suitable thermoluminescent dosimeters (TLD) for dose verification in ion beam irradiation are required. This paper investigates the TL response of nanocrystalline BaSO4 doped with Eu to 85 MeV carbon beam. The synthesis was done using Co-precipitation technique by mixing Barium chloride and ammonium sulphate solutions. To investigate the crystallinity and particle size, analytical techniques such as X-ray diffraction (XRD) and Transmission electron microscopy (TEM) were used which revealed the average particle sizes to 45 nm with orthorhombic structure. Samples in pellet form were irradiated by 85 MeV carbon beam in the fluence range of 1X1010-5X1013. TL glow curves of the irradiated samples show two prominent glow peaks at around 460 K and 495 K. The TL response is linear up to 1X1013 fluence after which saturation was observed. The wider linear TL response of nanocrystalline BaSO4: Eu and low fading make it a superior candidate as a dosimeter to be used for detecting the doses of carbon beam.Keywords: radiation, dosimetry, carbon ions, thermoluminescence
Procedia PDF Downloads 2876 A Follow up Study on Indoor 222Rn, 220Rn and Their Decay Product Concentrations in a Mineralized Zone of Himachal Pradesh, India
Authors: B. S. Bajwa, Parminder Singh, Prabhjot Singh, Surinder Singh, B. K. Sahoo, B. K. Sapra
Abstract:
A follow up study was taken up in a mineralized zone situated in Hamirpur district, Himachal Pradesh, India to investigate high values of radon concentration reported in past studies as well to update the old radon data based on bare SSNTD technique. In the present investigation, indoor radon, thoron and their decay products concentrations have been measured using the newly developed Radon-Thoron discriminating diffusion chamber with single entry face, direct radon and thoron progeny sensors (DRPS/DTPS) respectively. The measurements have been carried out in seventy five dwellings of fourteen different villages. Houses were selected taking into consideration of the past data as well as the type of houses such as mud, concrete, brick etc. It was observed that high values of earlier reported radon concentrations were mainly because of thoron interference in the Solid State Nuclear Track Detector (LR-115 type II) exposed in bare mode. Now, the average concentration values and the estimated annual inhalation dose in these villages have been found to be within the reference level as recommended by the ICRP. The annual average indoor radon and thoron concentrations observed in these dwellings have been found to vary from 44±12-157±73 Bq m-3 and 44±11-240±125 Bq m-3 respectively. The equilibrium equivalent concentrations of radon and thoron decay products have been observed to be in the range of 10-63 Bq m-3 and 1-5 Bq m-3 respectively.Keywords: radon, thoron, progeny concentration, dosimeter
Procedia PDF Downloads 4545 Approaching In vivo Dosimetry for Kilovoltage X-Ray Radiotherapy
Authors: Rodolfo Alfonso, David Alonso, Albin Garcia, Jose Luis Alonso
Abstract:
Recently a new kilovoltage radiotherapy unit model Xstrahl 200 - donated to the INOR´s Department of Radiotherapy (DR-INOR) in the framework of a IAEA's technical cooperation project- has been commissioned. This unit is able to treat shallow and low deep laying lesions, as it provides 8 discrete beam qualities, from 40 to 200 kV. As part of the patient-specific quality assurance program established at DR-INOR for external beam radiotherapy, it has been recommended to implement in vivo dose measurements (IVD), as they allow effectively discovering eventual errors or failures in the radiotherapy process. For that purpose a radio-photoluminescence (RPL) dosimetry system, model XXX, -also donated to DR-INOR by the same IAEA project- has been studied and commissioned. Main dosimetric parameters of the RPL system, such as reproducibility, linearity, and filed size influence were assessed. In a similar way, the response of radiochromic EBT3 type film was investigated for purposes of IVD. Both systems were calibrated in terms of entrance surface dose. Results of the dosimetric commissioning of RPL and EBT3 for IVD, and their pre-clinical implementation through end-to-end test cases are presented. The RPL dosimetry seems more recommendable for hyper-fractionated schemes with larger fields and curved patient contours, as those in chest wall irradiations, where the use of more than one dosimeter could be required. The radiochromic system involves smaller corrections with field size, but it sensibility is lower; hence it is more adequate for hypo-fractionated treatments with smaller fields.Keywords: glass dosimetry, in vivo dosimetry, kilovotage radiotherapy, radiochromic dosimetry
Procedia PDF Downloads 3984 Comparative Evaluation of EBT3 Film Dosimetry Using Flat Bad Scanner, Densitometer and Spectrophotometer Methods and Its Applications in Radiotherapy
Authors: K. Khaerunnisa, D. Ryangga, S. A. Pawiro
Abstract:
Over the past few decades, film dosimetry has become a tool which is used in various radiotherapy modalities, either for clinical quality assurance (QA) or dose verification. The response of the film to irradiation is usually expressed in optical density (OD) or net optical density (netOD). While the film's response to radiation is not linear, then the use of film as a dosimeter must go through a calibration process. This study aimed to compare the function of the calibration curve of various measurement methods with various densitometer, using a flat bad scanner, point densitometer and spectrophotometer. For every response function, a radichromic film calibration curve is generated from each method by performing accuracy, precision and sensitivity analysis. netOD is obtained by measuring changes in the optical density (OD) of the film before irradiation and after irradiation when using a film scanner if it uses ImageJ to extract the pixel value of the film on the red channel of three channels (RGB), calculate the change in OD before and after irradiation when using a point densitometer, and calculate changes in absorbance before and after irradiation when using a spectrophotometer. the results showed that the three calibration methods gave readings with a netOD precision of doses below 3% for the uncertainty value of 1σ (one sigma). while the sensitivity of all three methods has the same trend in responding to film readings against radiation, it has a different magnitude of sensitivity. while the accuracy of the three methods provides readings below 3% for doses above 100 cGy and 200 cGy, but for doses below 100 cGy found above 3% when using point densitometers and spectrophotometers. when all three methods are used for clinical implementation, the results of the study show accuracy and precision below 2% for the use of scanners and spectrophotometers and above 3% for precision and accuracy when using point densitometers.Keywords: Callibration Methods, Film Dosimetry EBT3, Flat Bad Scanner, Densitomete, Spectrophotometer
Procedia PDF Downloads 1343 Film Dosimetry – An Asset for Collaboration Between Cancer Radiotherapy Centers at Established Institutions and Those Located in Low- and Middle-Income Countries
Authors: A. Fomujong, P. Mobit, A. Ndlovu, R. Teboh
Abstract:
Purpose: Film’s unique qualities, such as tissue equivalence, high spatial resolution, near energy independence and comparatively less expensive dosimeter, ought to make it the preferred and widely used in radiotherapy centers in low and middle income countries (LMICs). This, however, is not always the case, as other factors that are often maybe taken for granted in advanced radiotherapy centers remain a challenge in LMICs. We explored the unique qualities of film dosimetry that can make it possible for one Institution to benefit from another’s protocols via collaboration. Methods: For simplicity, two Institutions were considered in this work. We used a single batch of films (EBT-XD) and established a calibration protocol, including scan protocols and calibration curves, using the radiotherapy delivery system at Institution A. We then proceeded and performed patient-specific QA for patients treated on system A (PSQA-A-A). Films from the same batch were then sent to a remote center for PSQA on radiotherapy delivery system B. Irradiations were done at Institution B and then returned to Institution A for processing and analysis (PSQA-B-A). The following points were taken into consideration throughout the process (a) A reference film was irradiated to a known dose on the same system irradiating the PSQA film. (b) For calibration, we utilized the one-scan protocol and maintained the same scan orientation of the calibration, PSQA and reference films. Results: Gamma index analysis using a dose threshold of 10% and 3%/2mm criteria showed a gamma passing rate of 99.8% and 100% for the PSQA-A-A and PSQA-B-A, respectively. Conclusion: This work demonstrates that one could use established film dosimetry protocols in one Institution, e.g., an advanced radiotherapy center and apply similar accuracies to irradiations performed at another institution, e.g., a center located in LMIC, which thus encourages collaboration between the two for worldwide patient benefits.Keywords: collaboration, film dosimetry, LMIC, radiotherapy, calibration
Procedia PDF Downloads 752 Robots for the Elderly at Home: For Men Only
Authors: Christa Fricke, Sibylle Meyer, Gert G. Wagner
Abstract:
Our research focuses on the question of whether assistive and social robotics could pose a promising strategy to support the independent living of elderly people and potentially relieve relatives of any anxieties. To answer the question of how elderly people perceive the potential of robotics, we analysed the data from the Berlin Aging Study BASE-II (https://www.base2.mpg.de/de) (N=1463) and data from the German SYMPARTNER study (http://www.sympartner.de) (N=120) and compared those to a control group made up of people younger than 30 years (BASE II: N=241; SYMPARTNER: N=30). BASE-II is a cohort study of people living in Berlin, Germany. The sample covers more than 2200 cases; a questionnaire on the use and acceptance of assistive and social robots was carried out with a sub-sample of 1463 respondents in 2015. The SYMPARTNER study was done by SIBIS institute of Social Research, Berlin and included a total of 120 persons between the ages of 60 and 87 in Berlin and the rural German federal state of Thuringia. Both studies included a control group of persons between the ages of 20 and 35 (BASE II: N=241; SYMPARTNER: N=30). Additional data, representative for the whole population in Germany, will be surveyed in fall 2017 (Survey “Technikradar” [technology radar] by the National Academy of Science and Engineering). Since this survey is including some identical questions as BASE-II/SYMPARTNER, comparative results can be presented at 20th International Conference on Social Robotics in New York 2018. The complexity of the data gathered in BASE-II and SYMPARTNER, encompassing detailed socio-economic background characteristics as well as personality traits such as the personal attitude to risk taking, locus of control and Big Five, proves highly valuable and beneficial. Results show that participants’ expressions of resentment against robots are comparatively low. Participants’ personality traits play a role, however the effect sizes are small. Only 15 percent of participants received domestic robots with great scepticism. Participants aged older than 70 years expressed greatest rejection of the robotic assistant. The effect sizes however account for only a few percentage points. Overall, participants were surprisingly open to the robot and its usefulness. The analysis also shows that men’s acceptance of the robot is generally greater than that of women (with odds ratios of about 0.6 to 0.7). This applies to both assistive robots in the private household and in care environments. Men expect greater benefits of the robot than women. Women tend to be more sceptical of their technical feasibility than men. Interview results prove our hypothesis that men, in particular of the age group 60+, are more accustomed to delegate household chores to women. A delegation to machines instead of humans, therefore, seems palpable. The answer to the title question of this planned presentation is: social and assistive robots at home robots are not only accepted by men – but by fewer women than men.Keywords: acceptance, care, gender, household
Procedia PDF Downloads 1971 An Infrared Inorganic Scintillating Detector Applied in Radiation Therapy
Authors: Sree Bash Chandra Debnath, Didier Tonneau, Carole Fauquet, Agnes Tallet, Julien Darreon
Abstract:
Purpose: Inorganic scintillating dosimetry is the most recent promising technique to solve several dosimetric issues and provide quality assurance in radiation therapy. Despite several advantages, the major issue of using scintillating detectors is the Cerenkov effect, typically induced in the visible emission range. In this context, the purpose of this research work is to evaluate the performance of a novel infrared inorganic scintillator detector (IR-ISD) in the radiation therapy treatment to ensure Cerenkov free signal and the best matches between the delivered and prescribed doses during treatment. Methods: A simple and small-scale infrared inorganic scintillating detector of 100 µm diameter with a sensitive scintillating volume of 2x10-6 mm3 was developed. A prototype of the dose verification system has been introduced based on PTIR1470/F (provided by Phosphor Technology®) material used in the proposed novel IR-ISD. The detector was tested on an Elekta LINAC system tuned at 6 MV/15MV and a brachytherapy source (Ir-192) used in the patient treatment protocol. The associated dose rate was measured in count rate (photons/s) using a highly sensitive photon counter (sensitivity ~20ph/s). Overall measurements were performed in IBATM water tank phantoms by following international Technical Reports series recommendations (TRS 381) for radiotherapy and TG43U1 recommendations for brachytherapy. The performance of the detector was tested through several dosimetric parameters such as PDD, beam profiling, Cerenkov measurement, dose linearity, dose rate linearity repeatability, and scintillator stability. Finally, a comparative study is also shown using a reference microdiamond dosimeter, Monte-Carlo (MC) simulation, and data from recent literature. Results: This study is highlighting the complete removal of the Cerenkov effect especially for small field radiation beam characterization. The detector provides an entire linear response with the dose in the 4cGy to 800 cGy range, independently of the field size selected from 5 x 5 cm² down to 0.5 x 0.5 cm². A perfect repeatability (0.2 % variation from average) with day-to-day reproducibility (0.3% variation) was observed. Measurements demonstrated that ISD has superlinear behavior with dose rate (R2=1) varying from 50 cGy/s to 1000 cGy/s. PDD profiles obtained in water present identical behavior with a build-up maximum depth dose at 15 mm for different small fields irradiation. A low dimension of 0.5 x 0.5 cm² field profiles have been characterized, and the field cross profile presents a Gaussian-like shape. The standard deviation (1σ) of the scintillating signal remains within 0.02% while having a very low convolution effect, thanks to lower sensitive volume. Finally, during brachytherapy, a comparison with MC simulations shows that considering energy dependency, measurement agrees within 0.8% till 0.2 cm source to detector distance. Conclusion: The proposed scintillating detector in this study shows no- Cerenkov radiation and efficient performance for several radiation therapy measurement parameters. Therefore, it is anticipated that the IR-ISD system can be promoted to validate with direct clinical investigations, such as appropriate dose verification and quality control in the Treatment Planning System (TPS).Keywords: IR-Scintillating detector, dose measurement, micro-scintillators, Cerenkov effect
Procedia PDF Downloads 182