Search results for: triangular patch antenna
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 573

Search results for: triangular patch antenna

3 Autologous Blood for Conjunctival Autograft Fixation in Primary Pterygium Surgery: a Systematic Review and Meta-Analysis

Authors: Mohamed Abdelmongy

Abstract:

Autologous Blood for Conjunctival Autograft Fixation in Primary Pterygium Surgery: A Systematic Review and Meta-analysis Hossam Zein1,2, Ammar Ismail1,3, Mohamed Abdelmongy1,4, Sherif Elsherif1,5,6, Ahmad Hassanen1,4, Basma Muhammad2, Fathy Assaf1,3, Ahmed Elsehili1,7, Ahmed Negida1,7, Shin Yamane9, Mohamed M. Abdel-Daim8,9 and Kazuaki Kadonosono9 https://www.ncbi.nlm.nih.gov/pubmed/30277146 BACKGROUND: Pterygium is a benign ocular lesion characterized by triangular fibrovascular growth of conjunctival tissue over the cornea. Patients complain of the bad cosmetic appearance, ocular surface irritation and decreased visual acuity if the pterygium is large enough to cause astigmatism or encroach on the pupil. The definitive treatment of pterygium is surgical removal. However, outcomes are compromised by recurrence . The aim of the current study is to systematically review the current literature to explore the efficacy and safety of fibrin glue, suture and autologous blood coagulum for conjunctivalautograft fixation in primary pterygium surgery. OBJECTIVES: To assess the effectiveness of fibrin glue compared to sutures and autologous blood coagulum in conjunctival autografting for the surgical treatment of pterygium. METHODS: During preparing this manuscript, we followed the steps adequately illustrated in the Cochrane Handbook for Systematic Reviews of Interventions version 5.3, and reported it according to the preferred reporting of systematic review and meta-analysis (PRISMA) statement guidelines. We searched PubMed, Ovid (both through Medline), ISI Web of Science, and Cochrane Central Register of Controlled Trials (Central) through January 2017, using the following keywords “Pterygium AND (blood OR glue OR suture)” SELECTION CRITERIA: We included all randomized controlled trials (RCTs) that met the following criteria: 1) comparing autologous blood vs fibrin glue for conjunctivalautograft fixation in primary pterygium surgery 2) comparing autologous blood vs sutures for conjunctivalautograft fixation in primary pterygium surgery DATA COLLECTION AND ANALYSIS: Two review authors independently screened the search results, assessed trial quality, and extracted data using standard methodological procedures expected by Cochrane. The extracted data included A) study design, sample size, and main findings, B) Baseline characteristics of patients included in this review including their age, sex, pterygium site and grade, and graft size. C) Study outcomes comprising 1) primary outcomes: recurrence rate 2) secondary outcomes: graft stability outcomes (graft retraction, graft displacement), operation time (min) and postoperative symptoms (pain, discomfort, foreign body sensation, tearing) MAIN RESULTS: We included 7 RCTs and The review included662eyes (Blood: 293; Glue: 198; Suture: 171). we assess the 1) primary outcomes: recurrence rate 2) secondary outcomes: graft stability outcomes (graft retraction, graft displacement), operation time (min) and postoperative symptoms (pain, discomfort, foreign body sensation, tearing) CONCLUSIONS: Autologous blood for conjunctivalautograft fixation in pterygium surgery is associated with lower graft stability than fibrin glue or sutures. It was not inferior to fibrin glue or sutures regarding recurrence rate. The overall quality of evidence is low. Further well designed RCTs are needed to fully explore the efficacy of this new technique.

Keywords: pterygium, autograft, ophthalmology, cornea

Procedia PDF Downloads 128
2 Sustainable Antimicrobial Biopolymeric Food & Biomedical Film Engineering Using Bioactive AMP-Ag+ Formulations

Authors: Eduardo Lanzagorta Garcia, Chaitra Venkatesh, Romina Pezzoli, Laura Gabriela Rodriguez Barroso, Declan Devine, Margaret E. Brennan Fournet

Abstract:

New antimicrobial interventions are urgently required to combat rising global health and medical infection challenges. Here, an innovative antimicrobial technology, providing price competitive alternatives to antibiotics and readily integratable with currently technological systems is presented. Two cutting edge antimicrobial materials, antimicrobial peptides (AMPs) and uncompromised sustained Ag+ action from triangular silver nanoplates (TSNPs) reservoirs, are merged for versatile effective antimicrobial action where current approaches fail. Antimicrobial peptides (AMPs) exist widely in nature and have recently been demonstrated for broad spectrum of activity against bacteria, viruses, and fungi. TSNP’s are highly discrete, homogenous and readily functionisable Ag+ nanoreseviors that have a proven amenability for operation within in a wide range of bio-based settings. In a design for advanced antimicrobial sustainable plastics, antimicrobial TSNPs are formulated for processing within biodegradable biopolymers. Histone H5 AMP was selected for its reported strong antimicrobial action and functionalized with the TSNP (AMP-TSNP) in a similar fashion to previously reported TSNP biofunctionalisation methods. A synergy between the propensity of biopolymers for degradation and Ag+ release combined with AMP activity provides a novel mechanism for the sustained antimicrobial action of biopolymeric thin films. Nanoplates are transferred from aqueous phase to an organic solvent in order to facilitate integration within hydrophobic polymers. Extrusion is used in combination with calendering rolls to create thin polymerc film where the nanoplates are embedded onto the surface. The resultant antibacterial functional films are suitable to be adapted for food packing and biomedical applications. TSNP synthesis were synthesized by adapting a previously reported seed mediated approach. TSNP synthesis was scaled up for litre scale batch production and subsequently concentrated to 43 ppm using thermally controlled H2O removal. Nanoplates were transferred from aqueous phase to an organic solvent in order to facilitate integration within hydrophobic polymers. This was acomplised by functionalizing the TSNP with thiol terminated polyethylene glycol and using centrifugal force to transfer them to chloroform. Polycaprolactone (PCL) and Polylactic acid (PLA) were individually processed through extrusion, TSNP and AMP-TSNP solutions were sprayed onto the polymer immediately after exiting the dye. Calendering rolls were used to disperse and incorporate TSNP and TSNP-AMP onto the surface of the extruded films. Observation of the characteristic blue colour confirms the integrity of the TSNP within the films. Antimicrobial tests were performed by incubating Gram + and Gram – strains with treated and non-treated films, to evaluate if bacterial growth was reduced due to the presence of the TSNP. The resulting films successfully incorporated TSNP and AMP-TSNP. Reduced bacterial growth was observed for both Gram + and Gram – strains for both TSNP and AMP-TSNP compared with untreated films indicating antimicrobial action. The largest growth reduction was observed for AMP-TSNP treated films demonstrating the additional antimicrobial activity due to the presence of the AMPs. The potential of this technology to impede bacterial activity in food industry and medical surfaces will forge new confidence in the battle against antibiotic resistant bacteria, serving to greatly inhibit infections and facilitate patient recovery.

Keywords: antimicrobial, biodegradable, peptide, polymer, nanoparticle

Procedia PDF Downloads 88
1 Long-Term Subcentimeter-Accuracy Landslide Monitoring Using a Cost-Effective Global Navigation Satellite System Rover Network: Case Study

Authors: Vincent Schlageter, Maroua Mestiri, Florian Denzinger, Hugo Raetzo, Michel Demierre

Abstract:

Precise landslide monitoring with differential global navigation satellite system (GNSS) is well known, but technical or economic reasons limit its application by geotechnical companies. This study demonstrates the reliability and the usefulness of Geomon (Infrasurvey Sàrl, Switzerland), a stand-alone and cost-effective rover network. The system permits deploying up to 15 rovers, plus one reference station for differential GNSS. A dedicated radio communication links all the modules to a base station, where an embedded computer automatically provides all the relative positions (L1 phase, open-source RTKLib software) and populates an Internet server. Each measure also contains information from an internal inclinometer, battery level, and position quality indices. Contrary to standard GNSS survey systems, which suffer from a limited number of beacons that must be placed in areas with good GSM signal, Geomon offers greater flexibility and permits a real overview of the whole landslide with good spatial resolution. Each module is powered with solar panels, ensuring autonomous long-term recordings. In this study, we have tested the system on several sites in the Swiss mountains, setting up to 7 rovers per site, for an 18 month-long survey. The aim was to assess the robustness and the accuracy of the system in different environmental conditions. In one case, we ran forced blind tests (vertical movements of a given amplitude) and compared various session parameters (duration from 10 to 90 minutes). Then the other cases were a survey of real landslides sites using fixed optimized parameters. Sub centimetric-accuracy with few outliers was obtained using the best parameters (session duration of 60 minutes, baseline 1 km or less), with the noise level on the horizontal component half that of the vertical one. The performance (percent of aborting solutions, outliers) was reduced with sessions shorter than 30 minutes. The environment also had a strong influence on the percent of aborting solutions (ambiguity search problem), due to multiple reflections or satellites obstructed by trees and mountains. The length of the baseline (distance reference-rover, single baseline processing) reduced the accuracy above 1 km but had no significant effect below this limit. In critical weather conditions, the system’s robustness was limited: snow, avalanche, and frost-covered some rovers, including the antenna and vertically oriented solar panels, leading to data interruption; and strong wind damaged a reference station. The possibility of changing the sessions’ parameters remotely was very useful. In conclusion, the rover network tested provided the foreseen sub-centimetric-accuracy while providing a dense spatial resolution landslide survey. The ease of implementation and the fully automatic long-term survey were timesaving. Performance strongly depends on surrounding conditions, but short pre-measures should allow moving a rover to a better final placement. The system offers a promising hazard mitigation technique. Improvements could include data post-processing for alerts and automatic modification of the duration and numbers of sessions based on battery level and rover displacement velocity.

Keywords: GNSS, GSM, landslide, long-term, network, solar, spatial resolution, sub-centimeter.

Procedia PDF Downloads 90