Search results for: sling
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6

Search results for: sling

6 Whitnall’s Sling Will Be an Alternative Method for the Surgical Correction of Poor Function Ptosis

Authors: Titap Yazicioglu

Abstract:

To examine the results of two different surgery in patients with severe ptosis and poor levator function. The records of 10 bilateral congenital ptosis patients, who underwent Whitnall’s sling surgery on one eyelid and frontalis sling surgery on the other were analyzed retrospectively. All patients had severe congenital ptosis(>4mm) and poor levator function (LF<4mm). Data regarding eyelid position, cosmetic outcomes, and postoperative complications were evaluated. All patients were assessed for a minimum of one year with regard to the amount of correction, residual ptosis and lagophthalmos. The study consisted of 10 patients, with an average age of 9.2±2.4 years. Preoperative diagnosis for all patients was noted as, the average LF was 3.4±0.51mm, vertical lid height was 3.5±0.52 mm and margin reflex distance-1 (MRD-1) was 0.4±0.51mm. The mean vertical lid height was measured as 7.1±0.73 mm in the frontalis sling group and 7.2±0.63 mm in the Whitnall’s sling group at the postoperative 1st month control. However, in patients with Whitnall’s sling, revision was performed with frontalis sling surgery due to failure in vertical lid height in the late postoperative period, and an average of 7.5±0.52 mm was achieved. Satisfactory results were obtained in all patients. Although postoperative lagophthalmitis developed in the frontalis sling group, none of them developed exposure keratitis. Granuloma was observed as sling infection in 2(20%) of the patients. Although Whitnall’s sling technique provides a natural look appearance without interfering with the functional result, we did not find it as successful as frontalis sling surgery in severe ptosis.

Keywords: congenital ptosis, frontalis suspension, Whitnall ligament, complications

Procedia PDF Downloads 75
5 Modified Norhaya Upper Limp Elevation Sling-Quick Approach Ensuring Timely Limb Elevation

Authors: Prem, Norhaya, Vwrene C., Mohammad Harris A., Amarjit, Fazir M.

Abstract:

Upper limb surgery is a common orthopedic procedure. After surgery, it is necessary to raise the patient's arm to reduce limb swelling and promote recovery. After an injury or surgery, swelling (edema) in the limbs is common. This swelling can be painful, cause stiffness, and affect movement and ability to do daily activities. One of the easiest ways to manage swelling is to elevate the swollen limb. The goal is to elevate the swollen limb slightly above the level of the heart. This helps the extra fluid move back towards the heart for circulation to the rest of the body. Conventional arm sling or pillows are usually placed under the arm to raise it, but in this way the arm cannot be fixed well and easily slide down, without ideal raising effect. Conventional arm sling need experience to tie the sling and this delay in the application process. To reduce the waiting time and cost, modified Norhaya upper limb elevation sling was designed and made readily available. The sling is made from calico fabric, readily available in the ward. Measurements of patients’ arm lengths are obtained, and fabric sizes are cut into the average arm lengths, as well as 1 size above and below. The cut calico fabric is then sewn together with thick sewing threads. Its application is easy and junior most staff or doctor will be able to apply it on patient. The time taken to set up the sling is also reduced. Feedback gathered from ground staff regarding ease of setting up the sling was tremendous and patient also feel comfort in the modified Norhaya sling. The device can freely adjust the raising height of the affected limb and effectively fix the affected limb to reduce its swelling, thus promoting recovery. This device is worthy to be clinically popularized and applied. The Modified Norhaya upper limb elevation sling is the quickest to set up and the delay in elevating the patient’s hand is significantly reduced. Moreover, it is reproducible and there is also significant cost savings.

Keywords: elevate, effective, sling, timely

Procedia PDF Downloads 164
4 Tension-Free Vaginal Tape Secur (TVT Secur) versus Tension-Free Vaginal Tape-Obturator (TVT-O) from inside to outside in Surgical Management of Genuine Stress Urinary Incontinence

Authors: Ibrahim Mohamed Ibrahim Hassanin, Hany Hassan Mostafa, Mona Mohamed Shaban, Ahlam El Said Kamel

Abstract:

Background: New so-called minimally invasive devices have been developed to limit groin pain after sling placement for treatment of stress urinary incontinence (SUI) to minimize the risk of postoperative pain and organ perforation. A new generation of suburethral slings was described that avoided skin incision to pull out and tension the sling. Evaluation of this device through prospective short-term series has shown controversial results compared with other tension-free techniques. The aim of this study is to compare success rates and complications for tension-free vaginal tape secur (TVT secur) and trans-obturator sub urethral tape inside-out technique (TVT-O) for treatment of stress urinary incontinence (SUI). Materials and Methods: Fifty patients with genuine SUI were divided into two groups: group S (n=25) were operated upon using (TVT secur) and group O (n=25) were operated upon using trans-obturator suburethral tape inside-out technique (TVT-O). Success rate, quality of life and postoperative complications such as groin pain, urgency, urine retention and vaginal tape erosion were reported in both groups at one, three, and six months after surgery. Results: As regards objective cure rate at one, three, six months intervals; there was a significant difference between group S (56%, 64%, and 60%), and group O (80%, 88%, and 88%) respectively (P <0.05). As regards subjective cure rate at one, three, six months intervals; there was a significant difference between group S (44%, 44%, and 48%), and group O (76%, 80%, and 80%) respectively (P <0.05). Quality of life (QoL) parameters improved significantly in cured patients with no difference between both groups. As regards complications, group O had a higher frequency of complications than group S; groin pain (12% vs 12% p= 0.05), urgency (4% (1 case) vs 0%), urine retention (8% (2 cases) vs 0%), vaginal tape erosion (4% (1 case) vs 0%). No cases were complicated with wound infection. Conclusion: Compared to TVT secur, TVT-O showed higher subjective and objective cure rates after six months but higher rate of complications. Both techniques were comparable as regards improvement of quality of life after surgery.

Keywords: stress urinary incontinence, trans-vaginal tape-obturator, TVT Secur, TVT-O

Procedia PDF Downloads 337
3 Rollet vs Rocket: A New in-Space Propulsion Concept

Authors: Arthur Baraov

Abstract:

Nearly all rocket and spacecraft propulsion concepts in existence today can be linked one way or the other to one of the two ancient warfare devices: the gun and the sling. Chemical, thermoelectric, ion, nuclear thermal and electromagnetic rocket engines – all fall into the first group which, for obvious reasons, can be categorized as “hot” space propulsion concepts. Space elevator, orbital tower, rolling satellite, orbital skyhook, tether propulsion and gravitational assist – are examples of the second category which lends itself for the title “cold” space propulsion concepts. The “hot” space propulsion concepts skyrocketed – literally and figuratively – from the naïve ideas of Jules Verne to the manned missions to the Moon. On the other hand, with the notable exception of gravitational assist, hardly any of the “cold” space propulsion concepts made any progress in terms of practical application. Why is that? This article aims to show that the right answer to this question has the potential comparable by its implications and practical consequences to that of transition from Jules Verne’s stillborn and impractical conceptions of space flight to cogent and highly fertile ideas of Konstantin Tsiolkovsky and Yuri Kondratyuk.

Keywords: propulsion, rocket, rollet, spacecraft

Procedia PDF Downloads 509
2 Osteosuture in Fixation of Displaced Lateral Third Clavicle Fractures: A Case Report

Authors: Patrícia Pires, Renata Vaz, Bárbara Teles, Marco Pato, Pedro Beckert

Abstract:

Introduction: The management of lateral third clavicle fractures can be challenging due to difficulty in distinguishing subtle variations in the fracture pattern, which may be suggestive of potential fracture instability. They occur most often in men between 30 and 50 years of age, and in individuals over 70 years of age, its distribution is equal between both men and women. These fractures account for 10%–30% of all clavicle fractures and roughly 30%–45% of all clavicle nonunion fractures. Lateral third clavicle fractures may be treated conservatively or surgically, and there is no gold standard, although the risk of nonunion or pseudoarthrosis impacts the recommendation of surgical treatment when these fractures are unstable. There are many strategies for surgical treatment, including locking plates, hook plates fixation, coracoclavicular fixation using suture anchors, devices or screws, tension band fixation with suture or wire, transacromial Kirschner wire fixation and arthroscopically assisted techniques. Whenever taking the hardware into consideration, we must not disregard that obtaining adequate lateral fixation of small fragments is a difficult task, and plates are more associated to local irritation. The aim of the appropriate treatment is to ensure fracture healing and a rapid return to preinjury activities of daily living but, as explained, definitive treatment strategies have not been established and the variety of techniques avalilable add up to the discussion of this topic. Methods and Results: We present a clinical case of a 43-year-old man with the diagnosis of a lateral third clavicle fracture (Neer IIC) in the sequence of a fall on his right shoulder after a bicycle fall. He was operated three days after the injury, and through K-wire temporary fixation and indirect reduction using a ZipTight, he underwent osteosynthesis with an interfragmentary figure-of-eight tension band with polydioxanone suture (PDS). Two weeks later, there was a good aligment. He kept the sling until 6 weeks pos-op, avoiding efforts. At 7-weeks pos-op, there was still a good aligment, starting the physiotherapy exercises. After 10 months, he had no limitation in mobility or pain and returned to work with complete recovery in strength. Conclusion: Some distal clavicle fractures may be conservatively treated, but it is widely accepted that unstable fractures require surgical treatment to obtain superior clinical outcomes. In the clinical case presented, the authors chose an osteosuture technique due to the fracture pattern, its location. Since there isn´t a consensus on the prefered fixation method, it is important for surgeons to be skilled in various techniques and decide with their patient which approach is most appropriate for them, weighting the risk-benefit of each method. For instance, with the suture technique used, there is no wire migration or breakage, and it doesn´t require a reoperation for hardware removal; there is also less tissue exposure since it requires a smaller approach in comparison to the plate fixation and avoids cuff tears like the hook plate. The good clinical outcome on this case report serves the purpose of expanding the consideration of this method has a therapeutic option.

Keywords: lateral third, clavicle, suture, fixation

Procedia PDF Downloads 42
1 Electromyographic Analysis of Biceps Brachii during Golf Swing and Review of Its Impact on Return to Play Following Tendon Surgery

Authors: Amin Masoumiganjgah, Luke Salmon, Julianne Burnton, Fahimeh Bagheri, Gavin Lenton, S. L. Ezekial Tan

Abstract:

Introduction: The incidence of proximal biceps tenodesis and acute distal biceps repair is increasing, and rehabilitation protocols following both are variable. Golf is a popular sport within Australia, and the Gold Coast has become a Mecca for golfers, with more courses per capita than anywhere else in the world. Currently, there are no clear guidelines regarding return to golf play following biceps procedures. The aim of this study was to determine biceps brachii activation during the golf swing through electromyographic analysis, and subsequently, aid in rehabilitation guidelines and return to golf following tenodesis and repair. Methods: Subjects were amateur golfers with no previous upper limb surgery. Surface electromyography (EMG) and high-speed video recording were used to analyse activation of the left and right biceps brachii and the anterior deltoid during the golf swing. Each participant’s maximum voluntary contraction (MVC) was recorded, and they were then required to hit a golf ball aiming for specific distances of 2, 50, 100 and 150 metres at a driving range. Noraxon myoResearch and Matlab were used for data analysis. Mean % MVC was calculated for leading and trailing arms during the full swing and its’ 4 phases: back-swing, acceleration, early follow-through and late follow-through. Results: 12 golfers (2 female and 10 male), participated in the study. Median age was 27 (25 – 38), with all being right handed. Over all distances, the mean activation of the short and long head of biceps brachii was < 10% through the full swing. When breaking down the 50, 100 and 150m swing into phases, mean MVC activation was lowest in backswing (5.1%), followed by acceleration (9.7%), early follow-through (9.2%), and late follow-through (21.4%). There was more variation and slightly higher activation in the right biceps (trailing arm) in backswing, acceleration, and early follow-through; with higher activation in the leading arm in late follow-through (25.4% leading, 17.3% trailing). 2m putts resulted in low MVC values (3.1% ) with little variation across swing phases. There was considerable individual variation in results – one tense subject averaged 11.0% biceps MVC through the 2m putting stroke and others recorded peak mean MVC biceps activations of 68.9% at 50m, 101.3% at 100m, and 111.3% at 150m. Discussion: Previous studies have investigated the role of rotator cuff, spine, and hip muscles during the golf swing however, to our knowledge, this is the first study that investigates the activation of biceps brachii. Many rehabilitation programs following a biceps tenodesis or repair allow active range against gravity and restrict strengthening exercises until 6 weeks, and this does not appear to be associated with any adverse outcome. Previous studies demonstrate a range of < 10% MVC is similar to the unloaded biceps brachii during walking(1), active elbow flexion with the hand positioned either in pronation or supination will produce MVC < 20% throughout range(2) and elbow flexion with a 4kg dumbbell can produce mean MVC’s of around 40%(3). Our study demonstrates that increasing activation is associated with the leading arm, increasing shot distance and the late follow-through phase. Although the cohort mean MVC of the biceps brachii is <10% through the full swing, variability is high and biceps activation reach peak mean MVC’s of over 100% in different swing phases for some individuals. Given these EMG values, caution is advised when advising patients post biceps procedures to return to long distance golf shots, particularly when the leading arm is involved. Even though it would appear that putting would be as safe as having an unloaded hand out of a sling following biceps procedures, the variability of activation patterns across different golfers would lead us to caution against accelerated golf rehabilitation in those who may be particularly tense golfers. The 50m short iron shot was too long to consider as a chip shot and more work can be done in this area to determine the safety of chipping.

Keywords: electromyographic analysis, biceps brachii rupture, golf swing, tendon surgery

Procedia PDF Downloads 55