4 Mitigation of Cascading Power Outage Caused Power Swing Disturbance Using Real-time DLR Applications

Authors: Dejenie Birile Gemeda, Wilhelm Stork

Abstract:

The power system is one of the most important systems in modern society. The existing power system is approaching the critical operating limits as views of several power system operators. With the increase of load demand, high capacity and long transmission networks are widely used to meet the requirement. With the integration of renewable energies such as wind and solar, the uncertainty, intermittence bring bigger challenges to the operation of power systems. These dynamic uncertainties in the power system lead to power disturbances. The disturbances in a heavily stressed power system cause distance relays to mal-operation or false alarms during post fault power oscillations. This unintended operation of these relays may propagate and trigger cascaded trappings leading to total power system blackout. This is due to relays inability to take an appropriate tripping decision based on ensuing power swing. According to the N-1 criterion, electric power systems are generally designed to withstand a single failure without causing the violation of any operating limit. As a result, some overloaded components such as overhead transmission lines can still work for several hours under overload conditions. However, when a large power swing happens in the power system, the settings of the distance relay of zone 3 may trip the transmission line with a short time delay, and they will be acting so quickly that the system operator has no time to respond and stop the cascading. Misfiring of relays in absence of fault due to power swing may have a significant loss in economic performance, thus a loss in revenue for power companies. This research paper proposes a method to distinguish stable power swing from unstable using dynamic line rating (DLR) in response to power swing or disturbances. As opposed to static line rating (SLR), dynamic line rating support effective mitigation actions against propagating cascading outages in a power grid. Effective utilization of existing transmission lines capacity using machine learning DLR predictions will improve the operating point of distance relay protection, thus reducing unintended power outages due to power swing.

Keywords: blackout, cascading outages, dynamic line rating, power swing, overhead transmission lines

Procedia PDF Downloads 108
3 Results of Three-Year Operation of 220kV Pilot Superconducting Fault Current Limiter in Moscow Power Grid

Authors: M. Moyzykh, I. Klichuk, L. Sabirov, D. Kolomentseva, E. Magommedov

Abstract:

Modern city electrical grids are forced to increase their density due to the increasing number of customers and requirements for reliability and resiliency. However, progress in this direction is often limited by the capabilities of existing network equipment. New energy sources or grid connections increase the level of short-circuit currents in the adjacent network, which can exceed the maximum rating of equipment–breaking capacity of circuit breakers, thermal and dynamic current withstand qualities of disconnectors, cables, and transformers. Superconducting fault current limiter (SFCL) is a modern solution designed to deal with the increasing fault current levels in power grids. The key feature of this device is its instant (less than 2 ms) limitation of the current level due to the nature of the superconductor. In 2019 Moscow utilities installed SuperOx SFCL in the city power grid to test the capabilities of this novel technology. The SFCL became the first SFCL in the Russian energy system and is currently the most powerful SFCL in the world. Modern SFCL uses second-generation high-temperature superconductor (2G HTS). Despite its name, HTS still requires low temperatures of liquid nitrogen for operation. As a result, Moscow SFCL is built with a cryogenic system to provide cooling to the superconductor. The cryogenic system consists of three cryostats that contain a superconductor part and are filled with liquid nitrogen (three phases), three cryocoolers, one water chiller, three cryopumps, and pressure builders. All these components are controlled by an automatic control system. SFCL has been continuously operating on the city grid for over three years. During that period of operation, numerous faults occurred, including cryocooler failure, chiller failure, pump failure, and others (like a cryogenic system power outage). All these faults were eliminated without an SFCL shut down due to the specially designed cryogenic system backups and quick responses of grid operator utilities and the SuperOx crew. The paper will describe in detail the results of SFCL operation and cryogenic system maintenance and what measures were taken to solve and prevent similar faults in the future.

Keywords: superconductivity, current limiter, SFCL, HTS, utilities, cryogenics

Procedia PDF Downloads 56
2 Simulation of Maximum Power Point Tracking in a Photovoltaic System: A Circumstance Using Pulse Width Modulation Analysis

Authors: Asowata Osamede

Abstract:

Optimized gain in respect to output power of stand-alone photovoltaic (PV) systems is one of the major focus of PV in recent times. This is evident to its low carbon emission and efficiency. Power failure or outage from commercial providers in general does not promote development to the public and private sector, these basically limit the development of industries. The need for a well-structured PV system is of importance for an efficient and cost-effective monitoring system. The purpose of this paper is to validate the maximum power point of an off-grid PV system taking into consideration the most effective tilt and orientation angles for PV's in the southern hemisphere. This paper is based on analyzing the system using a solar charger with MPPT from a pulse width modulation (PWM) perspective. The power conditioning device chosen is a solar charger with MPPT. The practical setup consists of a PV panel that is set to an orientation angle of 0o north, with a corresponding tilt angle of 36 o, 26o and 16o. The load employed in this set-up are three Lead Acid Batteries (LAB). The percentage fully charged, charging and not charging conditions are observed for all three batteries. The results obtained in this research is used to draw the conclusion that would provide a benchmark for researchers and scientist worldwide. This is done so as to have an idea of the best tilt and orientation angles for maximum power point in a basic off-grid PV system. A quantitative analysis would be employed in this research. Quantitative research tends to focus on measurement and proof. Inferential statistics are frequently used to generalize what is found about the study sample to the population as a whole. This would involve: selecting and defining the research question, deciding on a study type, deciding on the data collection tools, selecting the sample and its size, analyzing, interpreting and validating findings Preliminary results which include regression analysis (normal probability plot and residual plot using polynomial 6) showed the maximum power point in the system. The best tilt angle for maximum power point tracking proves that the 36o tilt angle provided the best average on time which in turns put the system into a pulse width modulation stage.

Keywords: power-conversion, meteonorm, PV panels, DC-DC converters

Procedia PDF Downloads 121
1 Policy Implications of Cashless Banking on Nigeria’s Economy

Authors: Oluwabiyi Adeola Ayodele

Abstract:

This study analysed the Policy and general issues that have arisen over time in Nigeria’ Cashless banking environment as a result of the lack of a Legal framework on Electronic banking in Nigeria. It undertook an in-depth study of the cashless banking system. It discussed the evolution, growth and development of cashless banking in Nigeria; It revealed the expected benefits of the cashless banking system; It appraised regulatory issues and other prevalent problems on cashless banking in Nigeria; and made appropriate recommendations where necessary. The study relied on primary and secondary sources of information. The primary sources included the Constitution of the Federal Republic of Nigeria, Statutes, Conventions and Judicial decisions, while the secondary sources included Books, Journals Articles, Newspapers and Internet Materials. The study revealed that cashless banking has been adopted in Nigeria but still at the developing stage. It revealed that there is no law for the regulation of cashless banking in Nigeria, what Nigeria relies on for regulation is the Central Bank of Nigeria’s Cashless Policy, 2014. The Banks and Other Financial Institutions Act Chapter B3, LFN, 2004 of Nigeria lack provision to accommodate issues on Internet banking. However, under the general principles of legality in criminal law, and by the provisions of the Nigerian Constitution, a person can only be punished for conducts that have been defined to be criminal by written laws with the penalties specifically stated in the law. Although Nigeria has potent laws for the regulation of paper banking, these laws cannot be substituted for paperless transactions. This is because the issues involved in both transactions vary. The study also revealed that the absence of law in the cashless banking environment in Nigeria will subject consumers to endless risks. This study revealed that the creation of banking markets via the Internet relies on both available technologies and appropriate laws and regulations. It revealed however that Law of some of the countries considered on cashless banking has taken care of most of the legal issues and other problems prevalent in the cashless banking environment. The study also revealed some other problems prevalent in the Nigerian cashless banking environment. The study concluded that for Nigeria to find solutions to the legal issues raised in its cashless banking environment and other problems of cashless banking, it should have a viable legal Frame work for internet banking. The study concluded that the Central Bank of Nigeria’s Policy on Cashless banking is not potent enough to tackle the challenges posed to cashless banking in Nigeria because policies only have a persuasive effect and not a binding effect. There is, therefore, a need for appropriate Laws for the regulation of cashless Banking in Nigeria. The study also concluded that there is a need to create more awareness of the system among Nigerians and solve infrastructural problems like prevalent power outage which often have been creating internet network problem.

Keywords: cashless-banking, Nigeria, policies, laws

Procedia PDF Downloads 463