Search results for: S. B. Babarinde
6 Experimental Investigation of R600a as a Retrofit for R134a in a Household Refrigerator
Authors: T. O Babarinde, F. A Oyawale, O. S Ohunakin, R. O Ohunakin, R. O Leramo D.S Adelekan
Abstract:
This paper presents an experimental study of R600a, environment-friendly refrigerants with low global warming potential (GWP), zero ozone depletion potential (ODP), as a substitute for R134a in domestic refrigerator. A refrigerator designed to work with R134a was used for this experiment, the capillary for this experiment was not varied at anytime during the experiment. 40, 60, 80g, charge of R600a were tested against 100 g of R134a under the designed capillary length of the refrigerator, and the performance using R600a was evaluated and compared with its performance when R134a was used. The results obtained showed that the design temperature and pull-down time set by International Standard Organisation (ISO) for small refrigerator was achieved using both 80g of R600a and 100g of R134a but R134a has earlier pulled down time than using R600a. The average coefficient of performance (COP) obtained using R600a is 17.7% higher than that of R134a while the average power consumption is 42.5 % lower than R134a, which shows that R600a can be used as replacement for R134a in domestic refrigerator without necessarily need to modified the capillary.Keywords: domestic refrigerator, experimental, R600a, R134a
Procedia PDF Downloads 5205 Published Financial Statement as a Correlate of Investment Decision among Commercial Bank Stakeholders in Nigeria
Authors: C. F. Popoola, K. Akinsanya, S. B. Babarinde, D. A. Farinde
Abstract:
This study investigated published financial statement as correlate of investment decision among commercial bank stakeholders in Nigeria. A correlation research design was used in the study. 180 users of published financial statement were purposively sampled from Lagos and Ibadan. Data generated were analyzed using Pearson correlation and regression. The findings of the study revealed that, balance sheet is negatively related with investment decision (r=-.483; p < .01) while income statement (r= .249; p < .001), notes on the account (r= .230; p < .001), cash flow statement (r= .202; p < .001), value added statement (r= .328; p < .001) and five-year financial summary (r= .191 ;p < .01) are positively related with investment decision. Findings also revealed that components of published financial statement significantly predicted good investment decision (R2= .983; F(5,175)=284.5; p < .05) for commercial bank stakeholders. Therefore, it was suggested that Nigeria banks and professional bodies should instigate programs that will increase the knowledge of stakeholders on published financial statement.Keywords: commercial banks, financial statement, income statement, investment decision, stakeholders
Procedia PDF Downloads 4594 Experimental Study of Mixture of R290/R600 to Replace R134a in a Domestic Refrigerator
Authors: T. O. Babarinde, B. O. Bolaji, S. O. Ismaila
Abstract:
Interest in natural refrigerants, such as hydrocarbons has been renewed in recent years because of the environmental problems associated with synthetic chlorofluorocarbon (CFC) and hydro-chlorofluorocarbon (HCFC) refrigerants. Due to the depletion of ozone-layer and global warming effects, synthetic refrigerants are being gradually phased out in accordance with the international protocols that aim to protect the environment. In this work, a refrigerator designed to work with R134a was used for this experiment, Liquefied Petroleum Gas (LPG) which consists of commercial propane and butane in a single evaporator domestic refrigerator with a total volume of 62 litres. In this experiment, type K thermocouples with their probes were used to measure the temperatures of four major components (evaporator, compressor, condenser and expansion device) of the refrigeration system. Also the system was instrumented with two pressure gauges at the inlet and outlet of the compressor for measuring the suction and discharged pressures. The experiments were carried out using 40, 60, 80,100g charges and the charges were measured with a digital charging scale. Thermodynamic properties of the LPG refrigerant were determined. The results obtained showed that using LPG charge of 60g. The system COP increased with 14.6% and the power consumption reduced with 9.8% when compared with R134a. Therefore, LPG can replace R134a in domestic refrigerator.Keywords: domestic refrigerator, experimental, LPG, R134a
Procedia PDF Downloads 4823 Experimental Study of a Mixture of R290/R600 to Replace R134a in a Domestic Refrigerator
Authors: T. O. Babarinde
Abstract:
Interest in natural refrigerants, such as hydrocarbons has been renewed in recent years because of the environmental problems associated with synthetic chlorofluorocarbon (CFC) and hydro-chlorofluorocarbon (HCFC) refrigerants. Due to the depletion of ozone-layer and global warming effects, synthetic refrigerants are being gradually phased out in accordance with the international protocols that aim to protect the environment. In this work, a refrigerator designed to work with R134a was used for this experiment, Liquefied Petroleum Gas (LPG) which consists of commercial propane and butane in a single evaporator domestic refrigerator with a total volume of 62 litres. In this experiment, type K thermocouples with their probes were used to measure the temperatures of four major components (evaporator, compressor, condenser and expansion device) of the refrigeration system. Also the system was instrumented with two pressure gauges at the inlet and outlet of the compressor for measuring the suction and discharged pressures. Four sets of experiments were carried out using different charges and the charges were measured with a digital charging scale. Thermodynamic properties of the LPG refrigerant were determined. The results obtained showed that the design temperature and pull-down time set by International Standard Organisation (ISO) for refrigerator was achieved using LPG charge of 60g. The system COP increases with 14.6% and the power consumption reduced with 9.8% when compared with R134a. Therefore, LPG can replace R134a in domestic refrigerator.Keywords: domestic refrigerator, experimental, R290/R600, R134a
Procedia PDF Downloads 4302 Economic Indicators as Correlates of Inward Foreign Direct Investment in Nigeria
Authors: C. F. Popoola, P. Osho, S. B. Babarinde
Abstract:
This study examined economic indicators as correlates of inward FDI. An exploratory research design was used to obtained annual published data on inflation rate, market size, exchange rate, political instability, human development, and infrastructure from Central Bank of Nigeria, National Bureau of Statistics, Nigerian Capital Market, Nigeria Institute of Social and Economic Research, and UNCTAD. Data generated were analyzed using Pearson correlation, analysis of variance and regression. The findings of the study revealed that market size (r = 0.852, p < 0.001), infrastructure (r = 0.264, p < 0.001), human development (r = 0.154, p < 0.01) and exchange rate ( r= 0.178, p < 0.05) correlate positively with inward FDI, while inflation rate (r = -0.88, p < 0.001), and political instability (r= -0.102, p < 0.05) correlate negatively with inward FDI. Findings also revealed that the economic indicators significantly predicted inward FDI (R2 = 0.913; F(1,19) = 29.40; p < 0.05) for Nigeria. It was concluded that exchange rate, market size, human development, and infrastructure positively related to inward FDI while the high level of inflation and political instability negatively related to inward FDI. Therefore, it was suggested that policy makers and government agencies should readdress steps and design policies that would encourage more FDI into the country.Keywords: exchange rate, foreign direct investment, human development, inflation rate, infrastructure, market size, political instability
Procedia PDF Downloads 4151 Preservative Potentials of Piper Guineense on Roma Tomato (Solanum lycopersicum) Fruit
Authors: Grace O. Babarinde, Adegoke O.Gabriel, Rahman Akinoso, Adekanye Bosede R.
Abstract:
Health risks associated with the use of synthetic chemicals to control post-harvest losses in fruit calls for use of natural biodegradable compounds. The potential of Piper guineense as postharvest preservative for Roma tomato (Solanum lycopersicum L.) was investigated. Freshly harvested red tomato (200 g) was dipped into five concentrations (1, 2, 3, 4 and 5% w/v) of P. guineense aqueous extract, while untreated fruits served as control. The samples were stored under refrigeration and analysed at 5-day interval for physico-chemical properties. P. guineense essential oil (EO) was characterised using GC-MS and its tomato preservative potential was evaluated. Percentage weight loss (PWL) in extract-treated tomato ranged from 0.0-0.68% compared to control (0.3-19.97%) during storage. Values obtained for firmness ranged from 8.23-16.88 N and 8.4 N in extract-treated and control. pH reduced from 5.4 to 4.5 and 3.7 in extract-treated and untreated samples, respectively. Highest value of Total Soluble Solid (1.8 °Brix) and maximum retention of Ascorbic acid (13.0 mg/100 g) were observed in 4% P. guineense-treated samples. Predominant P. guineense EO components were zingiberene (9.9%), linalool (10.7%), β-caryophyllene (12.6%), 1, 5-Heptadiene, 6-methyl-2-(4-methyl-3-cyclohexene-l-yl) (16.4%) and β-sesquiphellandrene (23.7%). Tomatoes treated with EO had lower PWL (5.2%) and higher firmness (14.2 N) than controls (15.3% and 11.9 N) respectively. The result indicates that P. guineense can be incorporated in to post harvest technology of Roma tomato fruit.Keywords: aqueous extract, essential oil, piper guineense, Roma tomato, storage condition
Procedia PDF Downloads 476