Search results for: Li Jianan
7 Multi-Objective Random Drift Particle Swarm Optimization Algorithm Based on RDPSO and Crowding Distance Sorting
Authors: Yiqiong Yuan, Jun Sun, Dongmei Zhou, Jianan Sun
Abstract:
In this paper, we presented a Multi-Objective Random Drift Particle Swarm Optimization algorithm (MORDPSO-CD) based on RDPSO and crowding distance sorting to improve the convergence and distribution with less computation cost. MORDPSO-CD makes the most of RDPSO to approach the true Pareto optimal solutions fast. We adopt the crowding distance sorting technique to update and maintain the archived optimal solutions. Introducing the crowding distance technique into MORDPSO can make the leader particles find the true Pareto solution ultimately. The simulation results reveal that the proposed algorithm has better convergence and distributionKeywords: multi-objective optimization, random drift particle swarm optimization, crowding distance sorting, pareto optimal solution
Procedia PDF Downloads 2556 A 10-Year In-Depth Follow-up of Post-lingual Hearing Loss Patients with Chinese Domestic Cochlear Implants
Authors: Jianan Li, Lusen Shi, Haiqiao Du, Wei Chen, Qian Wang, Shuoshuo Kang, Shiming Yang
Abstract:
Background: Follow-up of cochlear implant effectiveness is mainly focused on 3 years postoperatively, and studies with more than 5 years of observation are rare, especially for local Chinese brands. Objectives: Nurotron (Chinese domestic cochlear implant brand) CI recipients who participated in the clinical trial in 2009 were followed-up for 10 years prospectively, providing data to guide doctors and patients. Material and Methods: From December 2009 to April 2010, 57 subjects underwent Nurotron Venus CI surgery at multiple centers and were continued to be followed up and assessed at 1, 2, 3, 4, 5, and 10 years after switching on. Results: All recipients were successfully implanted with CIs with no difficulty in subsequent use, with one reported case of re-implantation 9 years after implantation. The aided hearing thresholds were significantly improved one month after switching on (p<0.0001) and remained stable afterward for 10 years. Speech recognition scores were significantly higher than pre-operative results (p<0.05) and continued to improve till 3 years after switching on. At 10 years of post-operation, most subjects had improved QOL scores in most sub-items. Conclusions and Significance: Nurotron Venus CI System provides long-term, stable results in hearing speech assistance capabilities and can improve the quality of life of CI recipients.Keywords: cochlear implantation, hearing loss, post lingual, follow up
Procedia PDF Downloads 155 Reactive Oxygen Species-Mediated Photoaging Pathways of Ultrafine Plastic Particles under UV Irradiation
Authors: Jiajun Duan, Yang Li, Jianan Gao, Runzi Cao, Enxiang Shang, Wen Zhang
Abstract:
Reactive oxygen species (ROS) generation is considered as an important photoaging mechanism of microplastics (MPs) and nanoplastics (NPs). To elucidate the ROS-induced MP/NP aging processes in water under UV365 irradiation, we examined the effects of surface coatings, polymer types, and grain sizes on ROS generation and photoaging intermediates. Bare polystyrene (PS) NPs generated hydroxyl radicals (•OH) and singlet oxygen (¹O₂), while coated PS NPs (carboxyl-modified PS (PS-COOH), amino-modified PS (PS-NH₂)) and PS MPs generated fewer ROS due to coating scavenging or size effects. Polypropylene, polyethylene, polyvinyl chloride, polyethylene terephthalate, and polycarbonate MPs only generated •OH. For aromatic polymers, •OH addition preferentially occurred at benzene rings to form monohydroxy polymers. Excess •OH resulted in H abstraction, C-C scission, and phenyl ring opening to generate aliphatic ketones, esters, aldehydes, and aromatic ketones. For coated PS NPs, •OH preferentially attacked the surface coatings to result in decarboxylation and deamination reactions. For aliphatic polymers, •OH attack resulted in the formation of carbonyl groups from peracid, aldehyde, or ketone via H abstraction and C-C scission. Moreover, ¹O₂ might participate in phenyl ring opening for PS NPs and coating degradation for coated PS NPs. This study facilitates understanding the ROS-induced weathering process of NPs/MPs in water under UV irradiation.Keywords: microplastics, nanoplastics, photoaging, reactive oxygen species, surface coating
Procedia PDF Downloads 1564 Magnetic Resonance Imaging in Cochlear Implant Patients without Magnet Removal: A Safe and Effective Workflow Management Program
Authors: Yunhe Chen, Xinyun Liu, Qian Wang, Jianan Li
Abstract:
Background Cochlear implants (CIs) are currently the primary effective treatment for severe or profound sensorineural hearing loss. As China's population ages and the number of young children rises, the demand for MRI for CI patients is expected to increase. Methods Reviewed MRI cases of 25 CI patients between 2015 and 2024, assessed imaging auditory outcomes and adverse reactions. Use the adverse event record sheet and accompanying medication sheet to record follow-up measures. Results Most CI patients undergoing MRI may face risks such as artifacts, pain, redness, swelling, tissue damage, bleeding, and magnet displacement or demagnetization. Twenty-five CI patients in our hospital were reviewed. Seven patient underwent 3.0 T MR, the others underwent 1.5 T MR. The manufacturers are 18 cases in Austria, 5 cases in Australia and 2 cases in Nurotron. Among them, one patient with bilateral CI underwent 1.5 T MR examination after head pressure bandaging, and the left magnet was displaced (CI24RE Series, Australia). This patient underwent surgical replacement of the magnet under general anesthesia. Six days after the operation, the patient's feedback indicated that the performance of the cochlear implant was consistent with the previous results following the reactivation of the external device. Based on the experience of our hospital, we proposed the feasible management scheme of MRI examination procedure for CI patients. This plan should include a module for confirming MRI imaging parameters, informed consent, educational materials for patients, and other safety measures to ensure that patients receive imaging results safely and effectively, implify clinical. Conclusion As indications for both MRI and cochlear implantation expand,the number of MRI studies recommended for patients with cochlear implants will also increase. The process and management scheme proposed in this study can help to obtain imaging results safely and effectively, and reduce clinical stress.Keywords: cochlear implantation, MRI, magnet, displacement
Procedia PDF Downloads 123 A Preliminary Analysis of The Effect After Cochlear Implantation in the Unilateral Hearing Loss
Authors: Haiqiao Du, Qian Wang, Shuwei Wang, Jianan Li
Abstract:
Purpose: The aim is to evaluate the effect of cochlear implantation (CI) in patients with unilateral hearing loss, with a view to providing data support for the selection of therapeutic interventions for patients with single-sided deafness (SSD)/asymmetric hearing loss (AHL) and the broadening of the indications for CI. Methods: The study subjects were patients with unilateral hearing loss who underwent cochlear implantation surgery in our hospital in August 2022 and were willing to cooperate with the test and were divided into 2 groups: SSD group and AHL group. The enrolled patients were followed up for hearing level, tinnitus changes, speech recognition ability, sound source localization ability, and quality of life at five-time points: preoperatively, and 1, 3, 6, and 12 months after postoperative start-up. Results: As of June 30, 2024, a total of nine patients completed follow-up, including four in the SSD group and five in the AHL group. The mean postoperative hearing aid thresholds on the CI side were 31.56 dB HL and 34.75 dB HL in the two groups, respectively. Of the four patients with preoperative tinnitus symptoms (three patients in the SSD group and one patient in the AHL group), all showed a degree of reduction in Tinnitus Handicap Inventory (THI) scores, except for one patient who showed no change. In both the SSD and AHL groups, the sound source localization results (expressed as RMS error values, with smaller values indicating better ability) were 66.87° and 77.41° preoperatively and 29.34° and 54.60° 12 months after postoperative start-up, respectively, which showed that the ability to localize the sound source improved significantly with longer implantation time. The level of speech recognition was assessed by 3 test methods: speech recognition rate of monosyllabic words in a quiet environment and speech recognition rate of different sound source directions at 0° and 90° (implantation side) in a noisy environment. The results of the 3 tests were 99.0%, 72.0%, and 36.0% in the preoperative SSD group and 96.0%, 83.6%, and 73.8% in the AHL group, respectively, whereas they fluctuated in the postoperative period 3 months after start-up, and stabilized at 12 months after start-up to 99.0%, 100.0%, and 100.0% in the SSD group and 99.5%, 96.0%, and 99.0%. Quality of life was subjectively evaluated by three tests: the Speech Spatial Quality of Sound Auditory Scale (SSQ-12), the Quality-of-Life Bilateral Listening Questionnaire (QLBHE), and the Nijmegen Cochlear Implantation Inventory (NCIQ). The results of the SSQ-12 (with a 10-point score out of 10) showed that the scores of preoperative and postoperative 12 months after start-up were 6.35 and 6.46 in the SSD group, while they were 5.61 and 9.83 in the AHL group. The QLBHE scores (100 points out of 100) were 61.0 and 76.0 in the SSD group and 53.4 and 63.7 in the AHL group for the preoperative versus the postoperative 12 months after start-up. Conclusion: Patients with unilateral hearing loss can benefit from cochlear implantation: CI implantation is effective in compensating for the hearing on the affected side and reduces the accompanying tinnitus symptoms; there is a significant improvement in sound source localization and speech recognition in the presence of noise; and the quality of life is improved.Keywords: single-sided deafness, asymmetric hearing loss, cochlear implant, unilateral hearing loss
Procedia PDF Downloads 142 Item-Trait Pattern Recognition of Replenished Items in Multidimensional Computerized Adaptive Testing
Authors: Jianan Sun, Ziwen Ye
Abstract:
Multidimensional computerized adaptive testing (MCAT) is a popular research topic in psychometrics. It is important for practitioners to clearly know the item-trait patterns of administered items when a test like MCAT is operated. Item-trait pattern recognition refers to detecting which latent traits in a psychological test are measured by each of the specified items. If the item-trait patterns of the replenished items in MCAT item pool are well detected, the interpretability of the items can be improved, which can further promote the abilities of the examinees who attending the MCAT to be accurately estimated. This research explores to solve the item-trait pattern recognition problem of the replenished items in MCAT item pool from the perspective of statistical variable selection. The popular multidimensional item response theory model, multidimensional two-parameter logistic model, is assumed to fit the response data of MCAT. The proposed method uses the least absolute shrinkage and selection operator (LASSO) to detect item-trait patterns of replenished items based on the essential information of item responses and ability estimates of examinees collected from a designed MCAT procedure. Several advantages of the proposed method are outlined. First, the proposed method does not strictly depend on the relative order between the replenished items and the selected operational items, so it allows the replenished items to be mixed into the operational items in reasonable order such as considering content constraints or other test requirements. Second, the LASSO used in this research improves the interpretability of the multidimensional replenished items in MCAT. Third, the proposed method can exert the advantage of shrinkage method idea for variable selection, so it can help to check item quality and key dimension features of replenished items and saves more costs of time and labors in response data collection than traditional factor analysis method. Moreover, the proposed method makes sure the dimensions of replenished items are recognized to be consistent with the dimensions of operational items in MCAT item pool. Simulation studies are conducted to investigate the performance of the proposed method under different conditions for varying dimensionality of item pool, latent trait correlation, item discrimination, test lengths and item selection criteria in MCAT. Results show that the proposed method can accurately detect the item-trait patterns of the replenished items in the two-dimensional and the three-dimensional item pool. Selecting enough operational items from the item pool consisting of high discriminating items by Bayesian A-optimality in MCAT can improve the recognition accuracy of item-trait patterns of replenished items for the proposed method. The pattern recognition accuracy for the conditions with correlated traits is better than those with independent traits especially for the item pool consisting of comparatively low discriminating items. To sum up, the proposed data-driven method based on the LASSO can accurately and efficiently detect the item-trait patterns of replenished items in MCAT.Keywords: item-trait pattern recognition, least absolute shrinkage and selection operator, multidimensional computerized adaptive testing, variable selection
Procedia PDF Downloads 1301 Development and Clinical Application of a Cochlear Implant Mapping Assistance System
Authors: Hong Mengdi, Li Jianan, Ji Fei, Chen Aiting, Wang Qian
Abstract:
Objective: To overcome the communication barriers that audiologists encounter during cochlear implant mapping, particularly the challenge of eliciting subjective feedback from recipients regarding electrical stimulation, and to enhance the capabilities of existing technologies, we teamed up with software engineers to design an interactive approach for patient-audiologist communication. This approach employs a tablet (PAD) as the interface for a communication and feedback system between patients and audiologists during the mapping process, known as the Cochlear Implant Mapping Assistance System. Methods: Capitalizing on the touchscreen functionality of the PAD, the recipients' subjective feedback during cochlear implant mapping is instantly transmitted to the audiologist's mapping computer. The system acts as a platform for auditory assessment instruments, facilitating immediate evaluation of recipients' post-mapping hearing and speech discrimination capabilities. Furthermore, the system is designed to augment the visual reinforcement audiometry (VRA) process. The system consists of six modules, including three testing projects: loudness testing, hearing threshold testing, and loudness balance testing; two assessment projects: warble tone testing and digit speech testing; and one VRA animation project. It also incorporates speech-to-text and text input display functions tailored to accommodate speech communication difficulties in hearing-impaired individuals, with pre-installed common exchange content between audiologists and recipients. Audiologists can input sentences by selecting options. The system supports switching between Chinese and English versions, suitable for audiologists and recipients who use English, facilitating international application of the system. Results: The Cochlear Implant Mapping Assistance System has been in use for over a year in the Auditory Implant Center of the Department of Otology and Neurotology, Medical Center of Otology and Head & Neck Surgery, Chinese PLA General Hospital, with more than 300 recipients using this mapping system. Currently, the system operates stably, with both audiologists and recipients providing positive feedback, indicating a significant improvement over previous methods. It is particularly well-received by pediatric recipients, significantly enhancing the work efficiency of audiologists and improving the feedback efficiency and accuracy of recipients. The system enhances the comprehensibility for cochlear implant recipients, improves wearing comfort and user experience, facilitates cochlear implant auditory mapping, and increases the collection of previously challenging-to-obtain data during the existing assisted mapping process, such as loudness testing data, electrical stimulation testing data, warble tone testing data, loudness balance testing data, digit speech testing data, and visual reinforcement audiometry testing data. Real-time data recording improves the accuracy of assisted mapping. The interface design is meticulously crafted to accommodate patients of varying ages and cognitive abilities, featuring an intuitive design that allows for effortless, guidance-free use by patients.Keywords: audiologist, subjective feedback, mapping, cochlear implant
Procedia PDF Downloads 20