This study has been performed with the goal of investigating the effectiveness of psychodrama in the reduction of social anxiety among the male adolescents in Kermanshah. 210 adolescents (13-14 year-olds) from four junior high schools in Kermanshah filled Liebowitz Social Anxiety Scale for Children and Adolescents (LSAS-CA) (Masia-Warner, Klien & Liebowitz, 2003). 30 of the adolescents who obtained the highest scores in LSAS-CA scale were chosen as the sample and were randomly assigned as experimental group (15 people) and control group (15 people). The experimental group participated in two-hour sessions of psychodrama twice a week for 6 weeks. The control group received no intervention. The findings of this study showed a significant reduction in the symptoms of social anxiety among the adolescents in experimental group in comparison to that of the control group. Also a three-month follow-up confirmed the stability of the results. Adolescents’ interactions in the psychodrama group, talking about their problems to the group, and achieving appropriate solutions by themselves are the useful factors of this intervention.

Keywords: psychodrama, social anxiety disorder, adolescents, male adolescents

Procedia PDF Downloads 420
1 Distributed Generation Connection to the Network: Obtaining Stability Using Transient Behavior

Authors: A. Hadadi, M. Abdollahi, A. Dustmohammadi

Abstract:

The growing use of DGs in distribution networks provide many advantages and also cause new problems which should be anticipated and be solved with appropriate solutions. One of the problems is transient voltage drop and short circuit in the electrical network, in the presence of distributed generation - which can lead to instability. The appearance of the short circuit will cause loss of generator synchronism, even though if it would be able to recover synchronizing mode after removing faulty generator, it will be stable. In order to increase system reliability and generator lifetime, some strategies should be planned to apply even in some situations which a fault prevent generators from separation. In this paper, one fault current limiter is installed due to prevent DGs separation from the grid when fault occurs. Furthermore, an innovative objective function is applied to determine the impedance optimal amount of fault current limiter in order to improve transient stability of distributed generation. Fault current limiter can prevent generator rotor's sudden acceleration after fault occurrence and thereby improve the network transient stability by reducing the current flow in a fast and effective manner. In fact, by applying created impedance by fault current limiter when a short circuit happens on the path of current injection DG to the fault location, the critical fault clearing time improve remarkably. Therefore, protective relay has more time to clear fault and isolate the fault zone without any instability. Finally, different transient scenarios of connection plan sustainability of small scale synchronous generators to the distribution network are presented.

Keywords: critical clearing time, fault current limiter, synchronous generator, transient stability, transient states

Procedia PDF Downloads 160