Search results for: Henk Corporaal
6 Approximate-Based Estimation of Single Event Upset Effect on Statistic Random-Access Memory-Based Field-Programmable Gate Arrays
Authors: Mahsa Mousavi, Hamid Reza Pourshaghaghi, Mohammad Tahghighi, Henk Corporaal
Abstract:
Recently, Statistic Random-Access Memory-based (SRAM-based) Field-Programmable Gate Arrays (FPGAs) are widely used in aeronautics and space systems where high dependability is demanded and considered as a mandatory requirement. Since design’s circuit is stored in configuration memory in SRAM-based FPGAs; they are very sensitive to Single Event Upsets (SEUs). In addition, the adverse effects of SEUs on the electronics used in space are much higher than in the Earth. Thus, developing fault tolerant techniques play crucial roles for the use of SRAM-based FPGAs in space. However, fault tolerance techniques introduce additional penalties in system parameters, e.g., area, power, performance and design time. In this paper, an accurate estimation of configuration memory vulnerability to SEUs is proposed for approximate-tolerant applications. This vulnerability estimation is highly required for compromising between the overhead introduced by fault tolerance techniques and system robustness. In this paper, we study applications in which the exact final output value is not necessarily always a concern meaning that some of the SEU-induced changes in output values are negligible. We therefore define and propose Approximate-based Configuration Memory Vulnerability Factor (ACMVF) estimation to avoid overestimating configuration memory vulnerability to SEUs. In this paper, we assess the vulnerability of configuration memory by injecting SEUs in configuration memory bits and comparing the output values of a given circuit in presence of SEUs with expected correct output. In spite of conventional vulnerability factor calculation methods, which accounts any deviations from the expected value as failures, in our proposed method a threshold margin is considered depending on user-case applications. Given the proposed threshold margin in our model, a failure occurs only when the difference between the erroneous output value and the expected output value is more than this margin. The ACMVF is subsequently calculated by acquiring the ratio of failures with respect to the total number of SEU injections. In our paper, a test-bench for emulating SEUs and calculating ACMVF is implemented on Zynq-7000 FPGA platform. This system makes use of the Single Event Mitigation (SEM) IP core to inject SEUs into configuration memory bits of the target design implemented in Zynq-7000 FPGA. Experimental results for 32-bit adder show that, when 1% to 10% deviation from correct output is considered, the counted failures number is reduced 41% to 59% compared with the failures number counted by conventional vulnerability factor calculation. It means that estimation accuracy of the configuration memory vulnerability to SEUs is improved up to 58% in the case that 10% deviation is acceptable in output results. Note that less than 10% deviation in addition result is reasonably tolerable for many applications in approximate computing domain such as Convolutional Neural Network (CNN).Keywords: fault tolerance, FPGA, single event upset, approximate computing
Procedia PDF Downloads 1985 Using Bamboo Structures for Protecting Mangrove Ecosystems: A Nature-Based Approach
Authors: Sourabh Harihar, Henk Jan Verhagen
Abstract:
The nurturing of a mangrove ecosystem requires a protected coastal environment with adequate drainage of the soil substratum. In a conceptual design undertaken for a mangrove rejuvenation project along the eastern coast of Mumbai (India), various engineering alternatives have been thought of as a protective coastal structure and drainage system. One such design uses bamboo-pile walls in creating shielded compartments in the form of various layouts, coupled with bamboo drains. The bamboo-based design is found to be environmentally and economically advantageous over other designs like sand-dikes which are multiple times more expensive. Moreover, employing a natural material such as bamboo helps the structure naturally blend with the developing mangrove habitat, allaying concerns about dismantling the structure post mangrove growth. A cost-minimising and eco-friendly bamboo structure, therefore, promises to pave the way for large rehabilitation projects in future. As mangrove ecosystems in many parts of the world increasingly face the threat of destruction due to urban development and climate change, protective nature-based designs that can be built in a short duration are the need of the hour.Keywords: bamboo, environment, mangrove, rehabilitation
Procedia PDF Downloads 2824 Utility of the Loop-Mediated Isothermal Amplification Assay for the Diagnosis of Visceral Leishmaniasis from Blood Samples in Ethiopia
Authors: Dawit Gebreegzabher Hagos, Yazezew Kebede Kiro, Mahmud Abdulkader, Henk H. D. F. Schallig, Dawit Wolday
Abstract:
Rapid and accurate visceral leishmaniasis (VL) diagnosis is needed to initiate prompt treatment to reduce morbidity and mortality. Here, we evaluated the performance of loop-mediated isothermal amplification (LAMP) assay for the diagnosis of VL from blood in an endemic area in Ethiopia. LAMP was positive in 117/122 confirmed VL cases and negative in 149/152 controls, resulting in a sensitivity of 95.9% (95% CI: 90.69–98.66) and a specificity of 98.0% (95% CI: 94.34–99.59), respectively. The sensitivity of the LAMP assay was 95.0% (95% CI: 88.61–98.34) in HIV-negatives and 100% (95% CI: 85.18–100.0) in HIV-positives. Compared with microscopy, LAMP detected 82/87 (94.3%, 95% CI: 87.10–98.11) of the microscopy1 cases and was negative in 11/27 (40.7%, 95% CI: 22.39–61.20) of the microscopy2 cases. Compared with the rK39 serology, LAMP detected 113/120 (94.2%, 95% CI: 88.35–97.62) of the rK391 cases and was negative in 149/154 (96.8%, 95% CI: 92.59–98.94) of the rK392 cases. However, when compared with microscopy only, rK39 detected 83/87 (95.4%, 95% CI: 88.64–98.73) of the microscopy1 cases and negative in only 12/27 (44.4%, 95% CI: 25.48–64.67) of the microscopy– cases. There was an excellent agreement between rK39 and LAMP (Kappa 5 0.91, 95% CI: 0.86–0.96). Furthermore, an algorithm using rK39 followed by LAMP would yield a sensitivity of 99.2% (95%CI: 95.52–99.89) and a specificity of 98.0% (95% CI: 94.34–99.59). The findings demonstrate that the LAMP assay is an accurate and rapid molecular assay for VL diagnosis, including in HIV-1 co-infected patients, in an endemic setting.Keywords: visceral leishmaniasis, HIV, diagnosis, LAMP, Ethiopia
Procedia PDF Downloads 983 Prenatal Use of Serotonin Reuptake Inhibitors (SRIs) and Congenital Heart Anomalies (CHA): An Exploratory Pharmacogenetics Study
Authors: Aizati N. A. Daud, Jorieke E. H. Bergman, Wilhelmina S. Kerstjens-Frederikse, Pieter Van Der Vlies, Eelko Hak, Rolf M. F. Berger, Henk Groen, Bob Wilffert
Abstract:
Prenatal use of SRIs was previously associated with Congenital Heart Anomalies (CHA). The aim of the study is to explore whether pharmacogenetics plays a role in this teratogenicity using a gene-environment interaction study. A total of 33 case-mother dyads and 2 mother-only (children deceased) registered in EUROCAT Northern Netherlands were included in a case-only study. Five case-mother dyads and two mothers-only were exposed to SRIs (paroxetine=3, fluoxetine=2, venlafaxine=1, paroxetine and venlafaxine=1) in the first trimester of pregnancy. The remaining 28 case-mother dyads were not exposed to SRIs. Ten genes that encode the enzymes or proteins important in determining fetal exposure to SRIs or its mechanism of action were selected: CYPs (CYP1A2, CYP2C9, CYP2C19, CYP2D6), ABCB1 (placental P-glycoprotein), SLC6A4 (serotonin transporter) and serotonin receptor genes (HTR1A, HTR1B, HTR2A, and HTR3B). All included subjects were genotyped for 58 genetic variations in these ten genes. Logistic regression analyses were performed to determine the interaction odds ratio (OR) between genetic variations and SRIs exposure on the risk of CHA. Due to low phenotype frequencies of CYP450 poor metabolizers among exposed cases, the OR cannot be calculated. For ABCB1, there was no indication of changes in the risk of CHA with any of the ABCB1 SNPs in the children and their mothers. Several genetic variations of the serotonin transporter and receptors (SLC6A4 5-HTTLPR and 5-HTTVNTR, HTR1A rs1364043, HTR1B rs6296 & rs6298, HTR3B rs1176744) were associated with an increased risk of CHA, but with too limited sample size to reach statistical significance. For SLC6A4 genetic variations, the mean genetic scores of the exposed case-mothers tended to be higher than the unexposed mothers (2.5 ± 0.8 and 1.88 ± 0.7, respectively; p=0.061). For SNPs of the serotonin receptors, the mean genetic score for exposed cases (children) tended to be higher than the unexposed cases (3.4 ± 2.2, and 1.9 ± 1.6, respectively; p=0.065). This study might be among the first to explore the potential gene-environment interaction between pharmacogenetic determinants and SRIs use on the risk of CHA. With small sample sizes, it was not possible to find a significant interaction. However, there were indications for a role of serotonin receptor polymorphisms in fetuses exposed to SRIs on fetal risk of CHA which warrants further investigation.Keywords: gene-environment interaction, heart defects, pharmacogenetics, serotonin reuptake inhibitors, teratogenicity
Procedia PDF Downloads 2192 Reliability of 2D Motion Analysis System for Sagittal Plane Lower Limb Kinematics during Running
Authors: Seyed Hamed Mousavi, Juha M. Hijmans, Reza Rajabi, Ron Diercks, Johannes Zwerver, Henk van der Worp
Abstract:
Introduction: Running is one of the most popular sports activity among people. Improper sagittal plane ankle, knee and hip kinematics are considered to be associated with the increase of injury risk in runners. Motion assessing smart-phone applications are increasingly used to measure kinematics both in the field and laboratory setting, as they are cheaper, more portable, accessible, and easier to use relative to 3D motion analysis system. The aims of this study are 1) to compare the results of 3D gait analysis system and CE; 2) to evaluate the test-retest and intra-rater reliability of coach’s eye (CE) app for the sagittal plane hip, knee, and ankle angles in the touchdown and toe-off while running. Method: Twenty subjects participated in this study. Sixteen reflective markers and cluster markers were attached to the subject’s body. Subjects were asked to run at a self-selected speed on a treadmill. Twenty-five seconds of running were collected for analyzing kinematics of interest. To measure sagittal plane hip, knee and ankle joint angles at touchdown (TD) and toe off (TO), the mean of first ten acceptable consecutive strides was calculated for each angle. A smartphone (Samsung Note5, android) was placed on the right side of the subject so that whole body was simultaneously filmed with 3D gait system during running. All subjects repeated the task with the same running speed after a short interval of 5 minutes in between. The CE app, installed on the smartphone, was used to measure the sagittal plane hip, knee and ankle joint angles at touchdown and toe off the stance phase. Results: Intraclass correlation coefficient (ICC) was used to assess test-retest and intra-rater reliability. To analyze the agreement between 3D and 2D outcomes, the Bland and Altman plot was used. The values of ICC were for Ankle at TD (TRR=0.8,IRR=0.94), ankle at TO (TRR=0.9,IRR=0.97), knee at TD (TRR=0.78,IRR=0.98), knee at TO (TRR=0.9,IRR=0.96), hip at TD (TRR=0.75,IRR=0.97), hip at TO (TRR=0.87,IRR=0.98). The Bland and Altman plots displaying a mean difference (MD) and ±2 standard deviation of MD (2SDMD) of 3D and 2D outcomes were for Ankle at TD (MD=3.71,+2SDMD=8.19, -2SDMD=-0.77), ankle at TO (MD=-1.27, +2SDMD=6.22, -2SDMD=-8.76), knee at TD (MD=1.48, +2SDMD=8.21, -2SDMD=-5.25), knee at TO (MD=-6.63, +2SDMD=3.94, -2SDMD=-17.19), hip at TD (MD=1.51, +2SDMD=9.05, -2SDMD=-6.03), hip at TO (MD=-0.18, +2SDMD=12.22, -2SDMD=-12.59). Discussion: The ability that the measurements are accurately reproduced is valuable in the performance and clinical assessment of outcomes of joint angles. The results of this study showed that the intra-rater and test-retest reliability of CE app for all kinematics measured are excellent (ICC ≥ 0.75). The Bland and Altman plots display that there are high differences of values for ankle at TD and knee at TO. Measuring ankle at TD by 2D gait analysis depends on the plane of movement. Since ankle at TD mostly occurs in the none-sagittal plane, the measurements can be different as foot progression angle at TD increases during running. The difference in values of the knee at TD can depend on how 3D and the rater detect the TO during the stance phase of running.Keywords: reliability, running, sagittal plane, two dimensional
Procedia PDF Downloads 2011 Consumer Utility Analysis of Halal Certification on Beef Using Discrete Choice Experiment: A Case Study in the Netherlands
Authors: Rosa Amalia Safitri, Ine van der Fels-Klerx, Henk Hogeveen
Abstract:
Halal is a dietary law observed by people following Islamic faith. It is considered as a type of credence food quality which cannot be easily assured by consumers even upon and after consumption. Therefore, Halal certification takes place as a practical tool for the consumers to make an informed choice particularly in a non-Muslim majority country, including the Netherlands. Discrete choice experiment (DCE) was employed in this study for its ability to assess the importance of attributes attached to Halal beef in the Dutch market and to investigate consumer utilities. Furthermore, willingness to pay (WTP) for the desired Halal certification was estimated. Four most relevant attributes were selected, i.e., the slaughter method, traceability information, place of purchase, and Halal certification. Price was incorporated as an attribute to allow estimation of willingness to pay for Halal certification. There were 242 Muslim respondents who regularly consumed Halal beef completed the survey, from Dutch (53%) and non-Dutch consumers living in the Netherlands (47%). The vast majority of the respondents (95%) were within the age of 18-45 years old, with the largest group being student (43%) followed by employee (30%) and housewife (12%). Majority of the respondents (76%) had disposable monthly income less than € 2,500, while the rest earned more than € 2,500. The respondents assessed themselves of having good knowledge of the studied attributes, except for traceability information with 62% of the respondents considered themselves not knowledgeable. The findings indicated that slaughter method was valued as the most important attribute, followed by Halal certificate, place of purchase, price, and traceability information. This order of importance varied across sociodemographic variables, except for the slaughter method. Both Dutch and non-Dutch subgroups valued Halal certification as the third most important attributes. However, non-Dutch respondents valued it with higher importance (0,20) than their Dutch counterparts (0,16). For non-Dutch, the price was more important than Halal certification. The ideal product preferred by the consumers indicated the product serving the highest utilities for consumers, and characterized by beef obtained without pre-slaughtering stunning, with traceability info, available at Halal store, certified by an official certifier, and sold at 2.75 € per 500 gr. In general, an official Halal certifier was mostly preferred. However, consumers were not willing to pay for premium for any type of Halal certifiers, indicated by negative WTP of -0.73 €, -0.93 €, and -1,03€ for small, official, and international certifiers, respectively. This finding indicated that consumers tend to lose their utility when confronted with price. WTP estimates differ across socio-demographic variables with male and non-Dutch respondents had the lowest WTP. The unfamiliarity to traceability information might cause respondents to perceive it as the least important attribute. In the context of Halal certified meat, adding traceability information into meat packaging can serve two functions, first consumers can justify for themselves whether the processes comply with Halal requirements, for example, the use of pre-slaughtering stunning, and secondly to assure its safety. Therefore, integrating traceability info into meat packaging can help to make informed decision for both Halal status and food safety.Keywords: consumer utilities, discrete choice experiments, Halal certification, willingness to pay
Procedia PDF Downloads 128