A Novel Dosimetry System for Computed Tomography using Phototransistor
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33090
A Novel Dosimetry System for Computed Tomography using Phototransistor

Authors: C. M. M. Paschoal, M. L. Sobrinho, D. do N. Souza, J. Antônio Filho, L. A. P. Santos

Abstract:

Computed tomography (CT) dosimetry normally uses an ionization chamber 100 mm long to estimate the computed tomography dose index (CTDI), however some reports have already indicated that small devices could replace the long ion chamber to improve quality assurance procedures in CT dosimetry. This paper presents a novel dosimetry system based in a commercial phototransistor evaluated for CT dosimetry. Three detector configurations were developed for this system: with a single, two and four devices. Dose profile measurements were obtained with them and their angular response were evaluated. The results showed that the novel dosimetry system with the phototransistor could be an alternative for CT dosimetry. It allows to obtain the CT dose profile in details and also to estimate the CTDI in longer length than the 100 mm pencil chamber. The angular response showed that the one device detector configuration is the most adequate among the three configurations analyzed in this study.

Keywords: Computed tomography, dosimetry, photo-transistor

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1055341

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1865

References:


[1] Aoyama, L., Koyama, S., Kawaura, C., 2002. An in-phantom dosimetry system using pin silicon photodiode radiation sensors for measuring organ doses in X ray CT and other diagnostic radiology. Med. Phys. 29, 1504-1510.
[2] Dixon, R.L., 2003. A new look at CT dose measurements: Beyond CTDI. Med. Phys. 30, 1272-1280.
[3] Hansson, J.; Eriksson, S.; Klang, A. T.; Bath, M., 2010. Comparison of three methods for determining CT dose profile: presenting the tritium method. Radiat. Prot. Dosim. 139, 434-438.
[4] Herrnsdorf, L., Björk, M., Cederquist, B., Mattsson, C. G., Thungström, G., Fröjdh, C., 2009. Point dose profile measurements using solid-state detectors in characterization of Computed Tomography systems. Nucl. Instrum. Methods Phys. Res. A 607, 223-225. Mettler Jr, F.A., Wiest, P. W., Locken, J. A., Kelsey, C. A., 2000. CT scanning: patterns of use and dose. J. Radiol. Prot. 20, 353-359.
[5] Mori, S., Endo, M., Nishizawa, K., Tsunoo, T., Aoyoma, T., Fujiwara, H., Murase, K., 2005. Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry Med. Phys. 32, 1061-1069.
[6] Nachonechny, K.D., Fallone, B. G., Rathee, S., 2005. Novel methods of measuring single scan dose profiles and cumulative dose in CT. Med. Phys. 32, 98-109.
[7] Rosenfeld, A.B., 2006. Electronic dosimetry in radiation therapy. Radiat. Meas. 41, S134-153.
[8] Santos, L.A.P., Magalhães, C. M. S., Silva, J. O., Antônio Filho, J., Silva Jr., E., Santos, W. M.., 2008. A feasibility study of a phototransistor for the dosimetry of computerized tomography and stereotactic radiosurgery beams. Radiat. Meas. 43, 904-907.
[9] Shrimpton, P. C., Hillier, M. C., Lewis, M. A., Dunn, M., 2006. National survey of dose from CT in the UK: 2003. J. Radiol. 79, 968- 980.