Power Frequency Magnetic Field Survey in Indoor Power Distribution Substation in Egypt
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Power Frequency Magnetic Field Survey in Indoor Power Distribution Substation in Egypt

Authors: Ahmed Hossam_ ElDin, Ahmed Farag, Ibrahim Madi., Hanaa Karawia

Abstract:

In our modern society electricity is vital to our health, safety, comfort and well-being. While our daily use of electricity is often taken for granted, public concern has arisen about potential adverse health effects from electric and magnetic – electromagnetic – fields (EMFs) produced by our use of electricity. This paper aims to compare between the measured magnetic field values and the simulated models for the indoor medium to low voltage (MV/LV) distribution substations. To calculate the magnetic flux density in the substations, interactive software SUBCALC is used which is based on closed form solution of the Biot-Savart law with 3D conductor model. The comparison between the measured values and the simulated models was acceptable. However there were some discrepancies, as expected, may be due to the current variation during measurements.

Keywords: Distribution substation, magnetic field, measurement, simulation.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1083337

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2308

References:


[1] "Application of ICNIRP Exposure Guidelines for 50 Hz Power Frequency Fields", available on http://www.icra.org/ratingsv02.html
[2] Exposure Standards Applicable In Europe and Elsewhere," (Brussels: Union of the Electricity Industry - EURELECTRIC, May 2003).
[3] A.S. Farag, T. Juhana Hashim, H. Hussain, I. Said, N. Abdul Rahman" Exposure Assessment of Electromagnetic Fields in Malaysian Public Schools Environment" , Proceeding of International Conference on Non-Ionizing Radiation at UNITEN (ICNIR2003),Electromagnetic Fields and Our Health, 20th-22nd October 2003.
[4] A Hossam El din, K Youssef and H Karawia, "Study And Evaluation Of Induced Currents In Human Body From Exposure To Electromagnetic Fields At Low Frequencies," Cired 20th International Conference on Electricity Distribution, Session 2,paper no.60, Prague, 8-11 June 2009.
[5] I. Said, A.S. Farag, H. Hussain, N.A. Rahman, "Measurement of Magnetic Field From Distribution Substations in Malaysia", Australasian Universities Power Engineering Conference (AUPEC 2004),paper no. 142, 26-29 September 2004, Brisbane, Australia.
[6] ANSI/ IEEE Std 644-1987,IEEE Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power Lines.
[7] A Hossam El din, I. Madi and H Karawia," Measurement and Analysis of Magnetic Fields in MV/LV Distribution Substation in Egypt",13th International Middle East Power Systems Conference, paper no.151,December 2009.
[8] H. B. San Segundo, C. C. García, V. F. Roig,T. Y. Vega,"Magnetic field reduction study for low voltage distribution panels located in MV/LV substations",19th International Conference, Electrical Power Quality and Utilization,Barcelona,9-11 October 2007.
[9] I.O.Habiballah, M.M.Dawoud,K.AL Balawi , A.S.Farag,"Magnetic Field Measurement& Simulation of A 230kV Substatio",Proceeding of the International Conference on Non- Ionizing Radiation at UNITEN (ICNIR 2003), Electromagnetic Fileds and Our Health, 20th-21th October 2003, Malaysia.