There is no reinforcement example for the renovation of the vertical and horizontal extension to existing building structures which is a shear wall type in apartment units in Korea. Among these existing structures, the structures which are shear wall type are rare overseas, while Korea has many shear wall apartment units. Recently, in Korea, a few researchers are trying to confirm the possibility of the vertical extension in existing building with shear walls. This study evaluates the possibility of the renovation by applying performance-based seismic design to existing buildings with shear walls in the analysis phase of the structure. In addition, force-based seismic design, used by general structural engineers in Korea, is carried out to compare the amount of reinforcement of walls, which is a main component of wall structure. As a result, we suggest that performance-based design obtains more economical advantages than force-based seismic design.Keywords: Vertical extension, performance-based design, renovation, shear wall structure, structural analysis.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1314889
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1086References:
[1] Code, K. B. (2009). Ministry of Land. Infrastructure and Transport, (2009-00). (in Korean)
[2] Code, K. B. (2016). Ministry of Land. Infrastructure and Transport, (2016-00). (in Korean)
[3] Council, L. T. B. S. D. (2011). An Alternative Procedure for Seismic Analysis and Design of Tall Buildings Located in the LA Region. LA Tall Buildings Structural Design Council.
[4] Tall Buildings Initiative. (2010). Guidelines for performance-based seismic design of tall buildings. Pacific Earthquake Engineering Research Center.
[5] Powell, G. H. (2007). Detailed Example of a Tall Shear Wall Building Using CSI's Perform 3D Nonlinear Dynamic Analysis. Computers & Structures Educational Services.
[6] Applied Technology Council (1978). Tentative Provisions for the Development of Seismic Regulations for Buildings, ATC3-06 Report. Redwood City. CA.
[7] IBC 2000 International Building Code, International Conf. of Building Officials, Whittier, CA.
[8] American Society of Civil Engineers. (2005). Minimum Design Loads for Buildings and Other Structures. ASCE 7-05. Reston, VA: ASCE.
[9] American Society of Civil Engineers. (2014). Seismic Evaluation and Retrofit of Existing Buildings: ASCE Standard ASCE/SEI 41-13. American Society of Civil Engineers.