3 Dextran Modified Silicon Photonic Microring Resonator Sensors
Authors: Jessie Yiying Quah, Vivian Netto, Jack Sheng Kee, Eric Mouchel La Fosse, Mi Kyoung Park
Abstract:
We present a dextran modified silicon microring resonator sensor for high density antibody immobilization. An array of sensors consisting of three sensor rings and a reference ring was fabricated and its surface sensitivity and the limit of detection were obtained using polyelectrolyte multilayers. The mass sensitivity and the limit of detection of the fabricated sensor ring are 0.35 nm/ng mm-2 and 42.8 pg/mm2 in air, respectively. Dextran modified sensor surface was successfully prepared by covalent grafting of oxidized dextran on 3-aminopropyltriethoxysilane (APTES) modified silicon sensor surface. The antibody immobilization on hydrogel dextran matrix improves 40% compared to traditional antibody immobilization method via APTES and glutaraldehyde linkage.Keywords: Antibody immobilization, Dextran, Immunosensor, Label-free detection, Silicon micro-ring resonator
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 22762 Tele-Operated Anthropomorphic Arm and Hand Design
Authors: Namal A. Senanayake, Khoo B. How, Quah W. Wai
Abstract:
In this project, a tele-operated anthropomorphic robotic arm and hand is designed and built as a versatile robotic arm system. The robot has the ability to manipulate objects such as pick and place operations. It is also able to function by itself, in standalone mode. Firstly, the robotic arm is built in order to interface with a personal computer via a serial servo controller circuit board. The circuit board enables user to completely control the robotic arm and moreover, enables feedbacks from user. The control circuit board uses a powerful integrated microcontroller, a PIC (Programmable Interface Controller). The PIC is firstly programmed using BASIC (Beginner-s All-purpose Symbolic Instruction Code) and it is used as the 'brain' of the robot. In addition a user friendly Graphical User Interface (GUI) is developed as the serial servo interface software using Microsoft-s Visual Basic 6. The second part of the project is to use speech recognition control on the robotic arm. A speech recognition circuit board is constructed with onboard components such as PIC and other integrated circuits. It replaces the computers- Graphical User Interface. The robotic arm is able to receive instructions as spoken commands through a microphone and perform operations with respect to the commands such as picking and placing operations.Keywords: Tele-operated Anthropomorphic Robotic Arm and Hand, Robot Motion System, Serial Servo Controller, Speech Recognition Controller.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 17661 Towards Innovation Performance among University Staff
Authors: C. S. Quah, S. P. L. Sim
Abstract:
This study examined how individuals in their respective teams contributed to innovation performance besides defining the term of innovation in their own respective views. This study also identified factors that motivated University staff to contribute to the innovation products. In addition, it examined whether there is a significant relationship between professional training level and the length of service among university staff towards innovation and to what extent do the two variables contributed towards innovative products. The significance of this study is that it revealed the strengths and weaknesses of the university staff when contributing to innovation performance. Stratified-random sampling was employed to determine the samples representing the population of lecturers in the study, involving 123 lecturers in one of the local universities in Malaysia. The method employed to analyze the data is through categorizing into themes for the open-ended questions besides using descriptive and inferential statistics for the quantitative data. This study revealed that two types of definition for the term “innovation” exist among the university staff, namely, creation of new product or new approach to do things as well as value-added creative way to upgrade or improve existing process and service to be more efficient. This study found that the most prominent factor that propels them towards innovation is to improve the product in order to benefit users, followed by selfsatisfaction and recognition. This implies that the staff in the organization viewed the creation of innovative products as a process of growth to fulfill the needs of others and also to realize their personal potential. This study also found that there was only a significant relationship between the professional training level and the length of service of 4 - 6 years among the university staff. The rest of the groups based on the length of service showed that there was no significant relationship with the professional training level towards innovation. Moreover, results of the study on directional measures depicted that the relationship for the length of service of 4- 6 years with professional training level among the university staff is quite weak. This implies that good organization management lies on the shoulders of the key leaders who enlighten the path to be followed by the staff.
Keywords: Innovation, length of service, performance, professional training level, motivation.