Search results for: Office equipment
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 572

Search results for: Office equipment

2 Towards Bridging the Gap between the ESP Classroom and the Workplace: Content and Language Needs Analysis in English for an Administrative Studies Course

Authors: Vesna Vulić

Abstract:

Croatia has made large steps forward in the development of higher education over the past 10 years. Purposes and objectives of the tertiary education system are focused on the personal development of young people so that they obtain competences for employment on a flexible labour market. The most frequent tensions between the tertiary institutions and employers are complaints that the current tertiary education system still supplies students with an abundance of theoretical knowledge and not enough practical skills. Polytechnics and schools of professional higher education should deliver professional education and training that will satisfy the needs of their local communities. The 21st century sets demand on undergraduates as well as their lecturers to strive for the highest standards. The skills students acquire during their studies should serve the needs of their future professional careers. In this context, teaching English for Specific Purposes (ESP) presents an enormous challenge for teachers. They have to cope with teaching the language in classes with a large number of students, limitations of time, inadequate equipment and teaching material; most frequently, this leads to focusing on specialist vocabulary neglecting the development of skills and competences required for future employment. Globalization has transformed the labour market and set new standards a perspective employee should meet. When knowledge of languages is considered, new generic skills and competences are required. Not only skillful written and oral communication is needed, but also information, media, and technology literacy, learning skills which include critical and creative thinking, collaborating and communicating, as well as social skills. The aim of this paper is to evaluate the needs of two groups of ESP first year Undergraduate Professional Administrative Study students taking ESP as a mandatory course: 47 first-year Undergraduate Professional Administrative Study students, 21 first-year employed part-time Undergraduate Professional Administrative Study students and 30 graduates with a degree in Undergraduate Professional Administrative Study with various amounts of work experience. The survey adopted a quantitative approach with the aim to determine the differences between the groups in their perception of the four language skills and different areas of law, as well as getting the insight into students' satisfaction with the current course and their motivation for studying ESP. Their perceptions will be compared to the results of the questionnaire conducted among sector professionals in order to examine how they perceive the same elements of the ESP course content and to what extent it fits into their working environment. The results of the survey indicated that there is a strong correlation between acquiring work experience and the level of importance given to particular areas of law studied in an ESP course which is in line with our initial hypothesis. In conclusion, the results of the survey should help lecturers in re-evaluating and updating their ESP course syllabi.

Keywords: English for Specific Purposes, ESP, language skills, motivation, needs analysis.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1084
1 Effect of Different Contaminants on Mineral Insulating Oil Characteristics

Authors: H. M. Wilhelm, P. O. Fernandes, L. P. Dill, C. Steffens, K. G. Moscon, S. M. Peres, V. Bender, T. Marchesan, J. B. Ferreira Neto

Abstract:

Deterioration of insulating oil is a natural process that occurs during transformers operation. However, this process can be accelerated by some factors, such as oxygen, high temperatures, metals and, moisture, which rapidly reduce oil insulating capacity and favor transformer faults. Parts of building materials of a transformer can be degraded and yield soluble compounds and insoluble particles that shorten the equipment life. Physicochemical tests, dissolved gas analysis (including propane, propylene and, butane), volatile and furanic compounds determination, besides quantitative and morphological analyses of particulate are proposed in this study in order to correlate transformers building materials degradation with insulating oil characteristics. The present investigation involves tests of medium temperature overheating simulation by means of an electric resistance wrapped with the following materials immersed in mineral insulating oil: test I) copper, tin, lead and, paper (heated at 350-400 °C for 8 h); test II) only copper (at 250 °C for 11 h); and test III) only paper (at 250 °C for 8 h and at 350 °C for 8 h). A different experiment is the simulation of electric arc involving copper, using an electric welding machine at two distinct energy sets (low and high). Analysis results showed that dielectric loss was higher in the sample of test I, higher neutralization index and higher values of hydrogen and hydrocarbons, including propane and butane, were also observed. Test III oil presented higher particle count, in addition, ferrographic analysis revealed contamination with fibers and carbonized paper. However, these particles had little influence on the oil physicochemical parameters (dielectric loss and neutralization index) and on the gas production, which was very low. Test II oil showed high levels of methane, ethane, and propylene, indicating the effect of metal on oil degradation. CO2 and CO gases were formed in the highest concentration in test III, as expected. Regarding volatile compounds, in test I acetone, benzene and toluene were detected, which are oil oxidation products. Regarding test III, methanol was identified due to cellulose degradation, as expected. Electric arc simulation test showed the highest oil oxidation in presence of copper and at high temperature, since these samples had huge concentration of hydrogen, ethylene, and acetylene. Particle count was also very high, showing the highest release of copper in such conditions. When comparing high and low energy, the first presented more hydrogen, ethylene, and acetylene. This sample had more similar results to test I, pointing out that the generation of different particles can be the cause for faults such as electric arc. Ferrography showed more evident copper and exfoliation particles than in other samples. Therefore, in this study, by using different combined analytical techniques, it was possible to correlate insulating oil characteristics with possible contaminants, which can lead to transformers failure.

Keywords: Ferrography, gas analysis, insulating mineral oil, particle contamination, transformer failures.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 409