Search results for: bronchoscopist
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2

Search results for: bronchoscopist

2 Efficacy and User Satisfaction on the Rama-Chest Cryo Arm Innovation for Bronchoscopic Cryotherapy

Authors: Chariya Laohavich

Abstract:

At the current, the trends in the lung disease at a university hospital are the treat and diagnosis by bronchoscopy. Bronchoscopic cryotherapy is a long time procedure 1-4 hours. The cryo probe is sensitive and easy to be damaged and expensive. We have this study management for protection the cryo probe, user satisfaction and qualities work. This study conducted in 4 stages: stage 1 for a survey of problems and assessment of user’s needs; stage 2 for designing and developing the Rama-chest cryo arm for a bronchoscopy process; stage 3 for test-implementing the Rama-chest cryo arm in real situations, studying its problems and obstacles, and evaluating the user satisfaction; and stage 4 for an overall assessment and improvement. The sample used in this study consisted of a total of 15 Ramathipbodi Hospital’s Bronchoscopist and bronchoscopist’s nurse who had used the Rama-chest cryo arm for bronchoscopic cryotherapy from January to June 2016. Objective: To study efficacy and user satisfaction on the Rama-chest cryo arm innovation for bronchoscopic cryotherapy. Data were collected using a Rama-chest cryo arm satisfaction assessment form and analysed based on mean and standard deviation. Result is the Rama-chest cryo arm was an innovation that accommodated during bronchoscopic cryotherapy. The subjects rated this the cryo arm as being most satisfactory (M = 4.86 ± , SD 0.48. Therefore we have developed a cryo arm that uses local material, practical and economic. Our innovation is not only flexible and sustainable development but also lean and seamless. This produced device can be used as effectively as the imported one, and thus can be eventually substituted.

Keywords: efficacy, satisfaction, Rama-chest cryo arm, innovation, bronchoscopic cryotherapy

Procedia PDF Downloads 206
1 User Satisfaction in Rama-Chest Mouthpiece for Flexible Bronchoscopy in Ramathibodi Hospital

Authors: Chariya Laohavich

Abstract:

Background: Some limitations and complications have been found associated with commercial mouthpiece in bronchoscopic procedure. Therefore, we invented the Rama-chest mouthpiece from plastic normal saline bottle. Objective: The aim of this study was to compare user satisfaction in Rama-chest mouthpiece with the commercial mouthpiece. Methods: A prospective randomized controlled trial between commercial mouthpiece and Rama-chest mouthpiece was conducted on patients who were underwent bronchoscopy and required mouthpiece insertion from May to June 2014. The questionnaire about satisfaction was completed by the bronchoscopists, assistant nurses, and patients. Results: Thirty procedures in both groups were investigated. Mean satisfaction scores filled by the bronchoscopists and assistant nurses were not different between both groups. However, higher satisfaction score filled by the patients was found in Rama-chest mouthpiece than the comparator (p=0.011). Complications such as abrasion, pain, and itching were observed in commercial mouthpiece but not found in Rama-chest mouthpiece. Conclusion: We have introduced Rama-chest mouthpiece and proved its usefulness comparable to the commercial mouthpiece.

Keywords: mouthpiece, bronchoscopist, bronchology, pulmonology and respiratory diseases

Procedia PDF Downloads 338