Search results for: Guo Xinli
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5

Search results for: Guo Xinli

5 Urban Rail Transit CBTC Computer Interlocking Subsystem Relying on Multi-Template Pen Point Tracking Algorithm

Authors: Xinli Chen, Xue Su

Abstract:

In the urban rail transit CBTC system, interlocking is considered one of the most basic sys-tems, which has the characteristics of logical complexity and high-security requirements. The development and verification of traditional interlocking subsystems are entirely manual pro-cesses and rely too much on the designer, which often hides many uncertain factors. In order to solve this problem, this article is based on the multi-template nib tracking algorithm for model construction and verification, achieving the main safety attributes and using SCADE for formal verification. Experimental results show that this method helps to improve the quality and efficiency of interlocking software.

Keywords: computer interlocking subsystem, penpoint tracking, communication-based train control system, multi-template tip tracking

Procedia PDF Downloads 129
4 An Automated Sensor System for Cochlear Implants Electrode Array Insertion

Authors: Lei Hou, Xinli Du, Nikolaos Boulgouris

Abstract:

A cochlear implant, referred to as a CI, is a small electronic device that can provide direct electrical stimulation to the auditory nerve. During cochlear implant surgery, atraumatic electrode array insertion is considered to be a crucial step. However, during implantation, the mechanical behaviour of an electrode array inside the cochlea is not known. The behaviour of an electrode array inside of the cochlea is hardly identified by regular methods. In this study, a CI electrode array capacitive sensor system is proposed. It is able to automatically determine the array state as a result of the capacitance variations. Instead of applying sensors to the electrode array, the capacitance information from the electrodes will be gathered and analysed. Results reveal that this sensing method is capable of recognising different states when fed into a pre-shaped model.

Keywords: cochlear implant, electrode, hearing preservation, insertion force, capacitive sensing

Procedia PDF Downloads 198
3 Rapid Generation of Octagonal Pyramids on Silicon Wafer for Photovoltaics by Swift Anisotropic Chemical Etching Process

Authors: Sami Iqbal, Azam Hussain, Weiping Wu, Guo Xinli, Tong Zhang

Abstract:

A novel octagonal upright micro-pyramid structure was generated by wet chemical anisotropic etching on a monocrystalline silicon wafer (100). The primary objectives are to reduce front surface reflectance of silicon wafers, improve wettability, enhance surface morphology, and maximize the area coverage by generated octagonal pyramids. Under rigorous control and observation, the etching process' response time was maintained precisely. The experimental outcomes show a significant decrease in the optical surface reflectance of silicon wafers, with the lowest reflectance of 8.98%, as well as enhanced surface structure, periodicity, and surface area coverage of more than 85%. The octagonal silicon pyramid was formed with a high etch rate of 0.41 um/min and a much shorter reaction time with the addition of hydrofluoric acid coupled with magnetic stirring (mechanical agitation) at 300 rpm.

Keywords: octagonal pyramids, rapid etching, solar cells, surface engineering, surface reflectance

Procedia PDF Downloads 66
2 Combined Mindfulness and Exercise Intervention for Depressive and Insomnia Symptoms in Chinese Students: A Pilot Randomized Controlled Trial

Authors: Xinli Chi, Xiaoqi Wei

Abstract:

Background: Body-mind theory refers to the concept that the mind and body are interconnected; in this case, combining aerobic exercise and mindfulness-based training may be beneficial for mind-body health; however, there is limited evidence regarding their effects and potential mechanisms among Chinese university students. Therefore, the current study aims to examine the preliminary effects and feasibility of the combined intervention on depressive and insomnia symptoms, as well as to explore the underlying mechanisms. Methods: This is a two-arm pilot study of a randomized, controlled trial. Sixty-one Chinese university students were randomly allocated to 8-week combined intervention group (aerobic exercise plus mindfulness, N = 36) or control group (N = 36). In addition, 8 participants in combined intervention group were later volunteer to engage in semi-structured interview. The Self-Rating Depression Scale (SDS) and the Youth Self-Rating Insomnia Scales (YSIS) were used to measure depressive and insomnia symptoms, respectively. The intervention outcome and feasibility were tested by repeated-measures ANOVA, mediation model, and qualitative analysis. Results: The study included 31 participants in the intervention group and 30 participants in the control group, all of whom completed pre-test and post-test questionnaires. The results of the repeated-measures ANOVA showed that the combined intervention was effective in reducing depressive and insomnia symptoms among university students. Moreover, the mediation analysis suggested that improvement in insomnia symptoms might be a significant mechanism for the combined intervention. Qualitative analysis identified two main themes: “Helpful aspects of mind-body state” (including 7 sub-themes) and “Factors that influence the training effects” (including 3 sub-themes). Conclusions: The study confirmed the preliminary effect and feasibility of the combined intervention of mindfulness and aerobic exercise, while also exploring the potential mechanisms underlying this effect. Additionally, qualitative data provided valuable insights for optimizing future protocols.

Keywords: combined intervention, mindfulness, aerobic exercise, depressive symptoms, insomnia symptoms

Procedia PDF Downloads 60
1 Design of Smart Catheter for Vascular Applications Using Optical Fiber Sensor

Authors: Lamiek Abraham, Xinli Du, Yohan Noh, Polin Hsu, Tingting Wu, Tom Logan, Ifan Yen

Abstract:

In the field of minimally invasive, smart medical instruments such as catheters and guidewires are typically used at a remote distance to gain access to the diseased artery, often negotiating tortuous, complex, and diseased vessels in the process. Three optical fiber sensors with a diameter of 1.5mm each that are 120° apart from each other is proposed to be mounted into a catheter-based pump device with a diameter of 10mm. These sensors are configured to solve the challenges surgeons face during insertion through curvy major vessels such as the aortic arch. Moreover, these sensors deal with providing information on rubbing the walls and shape sensing. This study presents an experimental and mathematical models of the optical fiber sensors with 2 degrees of freedom. There are two eight gear-shaped tubes made up of 3D printed thermoplastic Polyurethane (TPU) material that are connected. The optical fiber sensors are mounted inside the first tube for protection from external light and used TPU material as a prototype for a catheter. The second tube is used as a flat reflection for the light intensity modulation-based optical fiber sensors. The first tube is attached to the linear guide for insertion and withdrawal purposes and can manually turn it 45° by manipulating the tube gear. A 3D hard material phantom was developed that mimics the aortic arch anatomy structure in which the test was carried out. During the insertion of the sensors into the 3D phantom, datasets are obtained in terms of voltage, distance, and position of the sensors. These datasets reflect the characteristics of light intensity modulation of the optical fiber sensors with a plane project of the aortic arch structure shape. Mathematical modeling of the light intensity was carried out based on the projection plane and experiment set-up. The performance of the system was evaluated in terms of its accuracy in navigating through the curvature and information on the position of the sensors by investigating 40 single insertions of the sensors into the 3D phantom. The experiment demonstrated that the sensors were effectively steered through the 3D phantom curvature and to desired target references in all 2 degrees of freedom. The performance of the sensors echoes the reflectance of light theory, where the smaller the radius of curvature, the more of the shining LED lights are reflected and received by the photodiode. A mathematical model results are in good agreement with the experiment result and the operation principle of the light intensity modulation of the optical fiber sensors. A prototype of a catheter using TPU material with three optical fiber sensors mounted inside has been developed that is capable of navigating through the different radius of curvature with 2 degrees of freedom. The proposed system supports operators with pre-scan data to make maneuverability and bendability through curvy major vessels easier, accurate, and safe. The mathematical modelling accurately fits the experiment result.

Keywords: Intensity modulated optical fiber sensor, mathematical model, plane projection, shape sensing.

Procedia PDF Downloads 207