Development of a New Piezoelectrically Actuated Micropump for Liquid and Gas
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Development of a New Piezoelectrically Actuated Micropump for Liquid and Gas

Authors: Chiang-Ho Cheng, An-Shik Yang, Chih-Jer Lin, Chun-Ying Lee

Abstract:

This paper aims to present the design, fabrication and test of a novel piezoelectric actuated, check-valves embedded micropump having the advantages of miniature size, light weight and low power consumption. This device is designed to pump gases and liquids with the capability of performing the self-priming and bubble-tolerant work mode by maximizing the stroke volume of the membrane as well as the compression ratio via minimization of the dead volume of the micropump chamber and channel. By experiment apparatus setup, we can get the real-time values of the flow rate of micropump, the displacement of the piezoelectric actuator and the deformation of the check valve, simultaneously. The micropump with check valve 0.4 mm in thickness obtained higher output performance under the sinusoidal waveform of 120 Vpp. The micropump achieved the maximum pumping rates of 42.2 ml/min and back pressure of 14.0 kPa at the corresponding frequency of 28 and 20 Hz. The presented micropump is able to pump gases with a pumping rate of 196 ml/min at operating frequencies of 280 Hz under the sinusoidal waveform of 120 Vpp.

Keywords: Actuator, Check-valve, Micropump, Piezoelectric.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1093554

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2192

References:


[1] N T Nguyen, X Huang and T K Chuan, " MEMS-micropumps: a review,” ASME J. Fluids Eng. Vol. 124, pp. 384-392, 2002.
[2] D J Laser and J G Santiago, "A review of micropumps,” J. Micromech. Microeng. Vol. 14, pp. R35–R64, 2004.
[3] P Woias, "Micropumps-past, progress and future prospects,” Sensors Actuators B Vol. 105, pp. 28–38, 2005.
[4] N C Tsai and C Y Sue, "Review of MEMS-based drug delivery and dosing systems,” Sensors Actuators A Vol. 134, pp. 555–564, 2007.
[5] L Chen, S Lee, J Choo and E K Lee, "Continuous dynamic flow micropumps for microfluid manipulation,” J. Micromech. Microeng. Vol. 18, pp. 1–22, 2008.
[6] F Amirouche, Y Zhou and T Johnson, "Current micropump technologies and their biomedical applications,” Microsyst. Technol. Vol. 15 pp. 647-666, 2009.
[7] H Andersson, W van der Wijngaart, P Nilsson, P Enoksson and G Stemme, "A valve-less diffuser micropump for microfluidic analytical systems,” Sensors Actuators B Vol. 72, pp. 259–265, 2001.
[8] B Fan, G Song and F Hussain, "Simulation of a piezoelectrically actuated valveless micropump,” Smart Mater. Struct. Vol. 14, pp. 400–405, 2005.
[9] G H Feng and F S Kim, "Micropump based on PZT unimorph and one-way parylene valves,” J. Micromech. Microeng. Vol. 14, pp. 429–35, 2004.
[10] J Kang, J V Mantese and G W Auner, "A self-priming, high performance, check valve diaphragm micropump made from SOI wafers,” J. Micromech. Microeng. Vol. 18, pp. 1-8, 2009.
[11] R. Rapp, W K Schomburg, D. Maas, J. Schulz and W. Stark, "LIGA micropump for gases and liquids,” Sens. Actuators A Vol. 40, pp. 57–61, 1994.
[12] W K Schomburg, J. Fahrenberg, D. Maas, R. Rapp, "Active valves and pumps for microfluidics,” J. Micromechanics Microeng. Vol. 3, pp. 216–218, 1993.
[13] S Boehm, W Olthuis and P Bergveld, "A plastic micropump constructed with conventional techniques and materials,” Sensors Actuators A Vol. 77, pp. 223–228, 1999.
[14] S. Santra, P. Holloway, D. Batich, "Fabrication and testing of a magnetically actuated micropump,” Sens. Actuators B Vol. 87, pp. 358– 364, 2002.
[15] T Q Truong and N T Nguyen, "A polymeric piezoelectric micropump based on lamination technology,” J. Micromech. Microeng. Vol. 14, pp.632–638, 2004.
[16] J H Kim, K T Lau, R Shepherd, Y Wu, G Wallace and D Diamond, "Performance characteristics of a polypyrrole modified polydimethylsiloxane (PDMS) membrane based microfluidic pump,” Sensors and Actuators A Vol. 148, pp. 239–244, 2008.