Vibration Analysis of Gas Turbine SIEMENS 162MW - V94.2 Related to Iran Power Plant Industry in Fars Province
Authors: Omid A. Zargar
Abstract:
Vibration analysis of most critical equipment is considered as one of the most challenging activities in preventive maintenance. Utilities are heart of the process in big industrial plants like petrochemical zones. Vibration analysis methods and condition monitoring systems of these kinds of equipments are developed too much in recent years. On the other hand, there are too much operation factors like inlet and outlet pressures and temperatures that should be monitored. In this paper, some of the most effective concepts and techniques related to gas turbine vibration analysis are discussed. In addition, a gas turbine SIEMENS 162MW - V94.2 vibration case history related to Iran power industry in Fars province is explained. Vibration monitoring system and machinery technical specification are introduced. Besides, absolute and relative vibration trends, turbine and compressor orbits, Fast Fourier transform (FFT) in absolute vibrations, vibration modal analysis, turbine and compressor start up and shut down conditions, bode diagrams for relative vibrations, Nyquist diagrams and waterfall or three-dimensional FFT diagrams in startup and trip conditions are discussed with relative graphs. Furthermore, Split Resonance in gas turbines is discussed in details. Moreover, some updated vibration monitoring system, blade manufacturing technique and modern damping mechanism are discussed in this paper.
Keywords: Gas turbine, turbine compressor, vibration data collector, utility, condition monitoring, non-contact probe, Relative Vibration, Absolute Vibration, Split Resonance, Time Wave Form (TWF), Fast Fourier transform (FFT).
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1092994
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3681References:
[1] Ali Zargar O.2014. Turbine Compressor Vibration Analysis and Rotor movement Evaluation by Shaft Center Line Method (The Case History Related to Main Turbine Compressor of an Olefin Plant in Iran Oil Industries). World Academy of Science, Engineering and Technology. International Journal of Mechanical, Industrial Science and Engineering Vol: 8 No: 1.
[2] James C. Protection and Condition Monitoring of the LM6000 Gas Turbine. SKF Reliability Systems, 4141 Ruffin Road, San Diego, California 92123 USA, Web: www.skfreliability.com. 2003.
[3] Hsu T.R. 2008. MEMS and Microsystems Design and Manufacturing. Microsystems Design and Packaging Laboratory. Department of Mechanical and Aerospace Engineering. San Jose State University San Jose, California, USA.
[4] Hariharan V. and Srinivasan P.S.S. Vibrational Analysis of Flexible Coupling by Considering Unbalance. World Applied Sciences Journal, 8: 1022-1023. 2010.
[5] Ali Zargar O.2013. Vibration Analysis of an Alstom Typhoon Gas Turbine Power Plant Related to Iran Oil Industry. World Academy of Science, Engineering and Technology. International Journal of Mechanical, Industrial Science and Engineering Vol: 7 No: 11.
[6] Ali Zargar O.2013. Hydraulic Unbalance in Oil Injected Twin Rotary Screw Compressor Vibration Analysis (A Case History Related to Iran Oil Industries).World Academy of Science, Engineering and Technology. International Journal of Mechanical, Industrial Science and Engineering Vol:7 No:11.
[7] Ali Zargar O.2014. Detecting Cavitation in a Vertical Sea water Centrifugal Lift Pump Related to Iran Oil Industry Cooling Water Circulation System. World Academy of Science, Engineering and Technology. International Journal of Mechanical, Industrial Science and Engineering Vol: 8 No: 1.
[8] Ali Zargar O. 2014. Vibration, Lubrication and Machinery Consideration for a Mixer Gearbox Related to Iran Oil Industries. World Academy of Science, Engineering and Technology. International Journal of Mechanical, Industrial Science and Engineering Vol: 8 No: 3.
[9] Ali Zargar O. 2013. Vibration and Operation Technical Consideration before Field Balance of Gas Turbine Utilities (In Iran Power Plants SIEMENS V94.2 Gas Turbines).World Academy of Science, Engineering and Technology. International Journal of Mechanical, Industrial Science and Engineering Vol: 7 No: 11.
[10] Eftekhari M., Javadi M. and Farsani R.E. 2011. Free vibration analysis of cracked functionally graded material beam. World Applied Sciences Journal, 12:1223-1225.
[11] Sukirno A., Fajar R., Bismo S. and Nasikin M. 2009. Bio grease Based on Palm Oil and Lithium Soap Thickener: Evaluation of Anti wear Property. World Applied Sciences Journal, 6: 401-407.
[12] Karim Z., Nuawi M.Z., Ghani J.A., Abdullah S. and Ghazali M.J. 2011. Optimization of Integrated Kurtosis-Based Algorithm for Z-Filter (I-KazTM) Coefficient Using Multi Level Signal Decomposition Technique. World Applied Sciences Journal, 14:1546-1548.
[13] Alsaade F., Zaman N., Abdullah A. and Zafar Dawood M. 2012. Enhancing Surveillance and Security of Oil Pipelines Transportation Using Wireless Sensor Network. Middle-East Journal of Scientific Research, 11:1029-1030.
[14] Akhshabi M. A New Fuzzy Multi Criteria Model for Maintenance Policy. 2011. Middle-East Journal of Scientific Research, 10:33-38.
[15] http://tgs.freshpatents.com/Gas-Turbine-bx1.php,2013.
[16] Siemens website, Siemens Gas Turbines, Technical Papers. http://www.energy.siemens.com,2012.
[17] David R. Clarke, Matthias Oechsner and N.P. Padture, Guest Editors. Thermal-barrier coatings for more efficient gas-turbine engines. MRS bulletin volume 37 October 2012. Available on line at: www.mrs.org/bulletin.
[18] Advanced power with a new standard of high efficiency and operational flexibility. Flex Efficiency fifty Combined Cycle Power Plant. GE Energy.2013.
[19] Phil Ratliff, Paul Garbett and Willibald Fischer. The New Siemens Gas Turbine SGT5-8000H for More Customer Benefit. Reprint from VGB Power Tech, September 2007.
[20] I learn vibration-training website: http://www.mobiusinstitute.com/,2013.
[21] Azadi M., Azadi E. and Roopaei M. 2011. Adaptive Inverse Dynamics Control for Vibration Suppression of Flexible Panel with Piezoelectric Layers. World Applied Sciences Journal, 12: 2343-2351.
[22] Abu-El-Yazied T.G., Abu-El-Haggag S.Y. and Al-Fares F.S. 2009. Identification of Vibrating Structures with Application to a Steel Tower. World Applied Sciences Journal, 6: 1673-1674.
[23] Hosseini H., Ganji D.D., Abaspour M. and Kaliji H.D. 2011. Effect of Axial Force on Natural Frequency of Lateral Vibration of Flexible Rotating Shafts. World Applied Sciences Journal, 15: 858-859.
[24] Afkhami H., Argha A., Ropaee M. and Noori M.A. 2011. Surveying the control loops of the governor of the V94.2 gas turbine. World Applied Sciences Journal, 15: 1438-1440.