Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Natural Ventilation as a Design Strategy for Energy Saving
Authors: Zahra Ghiabaklou
Abstract:
Ventilation is a fundamental requirement for occupant health and indoor air quality in buildings. Natural ventilation can be used as a design strategy in free-running buildings to: • Renew indoor air with fresh outside air and lower room temperatures at times when the outdoor air is cooler. • Promote air flow to cool down the building structure (structural cooling). • Promote occupant physiological cooling processes (comfort cooling). This paper focuses on ways in which ventilation can provide the mechanism for heat dissipation and cooling of the building structure..It also discusses use of ventilation as a means of increasing air movement to improve comfort when indoor air temperatures are too high. The main influencing factors and design considerations and quantitative guidelines to help meet the design objectives are also discussed.Keywords: Natural Ventilation, Sustainable Building, Passive Cooling, Energy Saving
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1073441
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2680References:
[1] Warren, P. R., and Parkins, L. M. 1984. Single Sided Ventilation Through Open Windows. In Proc. Windows in Building Design and Maintenance. Jitterbug, Sweden. p.487.
[2] Evans, B. H. 1979. Energy Conservation with Natural Airflow Through Windows. ASHRAE Transactions, 852:641 650.
[3] Reed, R. H. 1953. Design for Natural Ventilation in Hot Humid Weather--Reprint from Housing and Building in Hot Humid and Hot Dry Climates. Washington, D.C.: Building Research Institute, National Academy of Sciences, National Research Council.
[4] Bowen, A. 1981. Classification of Air Motion Systems and Patterns. Proceeding of the International Passive and Hybrid Cooling Conference. American Section of the International Solar Energy Society. Miami Beach. p. 743-763.
[5] Bahadori, M. 1988. A Passive Cooling System for Hot Arid Regions. 13th National Passive Solar Conference. Cambridge, USA, pp 364-367.
[6] Fleury, B. 1990. Ventilative Cooling: State of the Art. Workshop on Passive Cooling. Ispra, 2-4 April.
[7] Holleman, T. R. 1951. Air Flow through Conventional Window Openings. RR-33, College Station, TX: Texas A&M University, Texas Engineering Experiment Station.
[8] Givoni, B. 1976. Man, Climate and Architecture, 2nd Edition, London: Applied Science.
[9] Givoni, B. 1968. Ventilation Problems in Hot Countries. Research Report to Ford Foundation, Haifa, Israel: Building Research Station, Israel Institute of Technology.
[10] Chandra, S. 1980. Passive Cooling by Natural Ventilation Principles and Design Implications. Passive Cooling Applications Handbook, Prepared for the Passive Cooling Workshop Amherst, Massachusetts.
[11] Sobin, H. J. 1981. Window Design for Passive Ventilating Cooling an Experiment Model Scale Study. In Proc. International Passive and Hybrid Cooling Conference. Miami Beach, FL. Boulder, CO: AS/ISES, pp. 191-195.
[12] Aynsley, R. M., Melbourne, W. and Vickery, B. J. 1977. Architectural Aerodynamics. London: Applied Science Publishers.
[13] Van Straaten, J. F., 1967. Thermal Performance Of Buildings. Amsterdam: Elsevier.
[14] Nielsen, 1974. Ph.D. Thesis, Technical University of Denmark.
[15] Ishizu, Y. and Kaneki, K. 1984. Evaluation of Ventilation Systems Through Numerical Computation and Presentation of a New Ventilation Model. Trans. SHASE 24:47 57.
[16] White, R. F. 1954. Effects of Landscape Development on the Natural Ventilation on Buildings and Their Adjacent Areas. RR-45, College Station, TX: Texas A&M University, Texas Engineering Experiment Station.
[17] Evans, B. H. 1979. Energy Conservation with Natural Airflow Through Windows. ASHRAE Transactions, 852:641 650.
[18] Sobin, H. J. 1980. Window Design for Passive Ventilative Cooling: An Experimental Study. Passive Cooling Applications Handbook, Prepared for the Passive Cooling Workshop Amherst, Massachusetts.
[19] Givoni, B. 1962. Basic Study of Ventilation Problems in Housing in Hot Countries, Final Report, Building Research Station, Technion - Israel Institute of Technology, Haifa.
[20] Sobin, H. J. 1980. Window Design for Passive Ventilative Cooling: An Experimental Study. Passive Cooling Applications Handbook, Prepared for the Passive Cooling Workshop Amherst, Massachusetts.