Hazardous Waste Management of Transmission Line Tower Manufacturing
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33093
Hazardous Waste Management of Transmission Line Tower Manufacturing

Authors: S.P.Gautam, P.S.Bundela, R.K. Jain, V. N. Tripathi

Abstract:

The manufacturing transmission line tower parts has being generated hazardous waste which is required proper disposal of waste for protection of land pollution. Manufacturing Process in the manufacturing of steel angle, plates, pipes, channels are passes through conventional, semi automatic and CNC machines for cutting, marking, punching, drilling, notching, bending operations. All fabricated material Coated with thin layer of Zinc in Galvanizing plant where molten zinc is used for coating. Prior to Galvanizing, chemical like 33% concentrated HCl Acid, ammonium chloride and d-oil being used for pretreatment of iron. The bath of water with sodium dichromate is used for cooling and protection of the galvanized steel. For the heating purpose the furnace oil burners are used. These above process the Zinc dross, Zinc ash, ETP sludge and waste pickled acid generated as hazardous waste. The RPG has made captive secured land fill site, since 1997 since then it was using for disposal of hazardous waste after completion of SLF (Secured land fill) site. The RPG has raised height from ground level then now it is being used for disposal of waste as he designed the SLF after in creasing height of from GL it is functional without leach ate or adverse impacts in the environment.

Keywords: Disposal, Drilling, Fabricated. Hazardous waste, Punching.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1072445

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1644

References:


[1] BC Hydro. 2006. BC Hydro 7 Steps to Electrical Safety. Available online at: http://www.bchydro.com/safety/work/work671.html.
[2] Blackwell B.A., G. Shrimpton, F. Steele, D.W. Ohlson and A. Needoba. 2004. Development of a Wildfire Risk Management System for BC Transmission Corporation Rights-of-Way. Technical Report submitted to British Columbia Transmission Corporation.
[3] Carlisle, S.M., and J.T. Trevors. 1987. Glyphosate in the environment. Water, Air, and Soil Poll. 39:409-20.
[4] California Energy Commission. 2005. Assessment of Avian Mortality from Collisions and Electrocutions. Staff Report prepared June, 2005.
[5] Crowder, Michael R. and Olin E. Rhodes, Jr. 1999. Avian Collisions with Power Lines: A Review. Proceedings of a workshop on Avian Interactions with Utility and Communication Structures Charleston, South Carolina, December 2-3 1999. Edited by Richard G. Carlton. Electric Power Research Institute.
[6] Roberto Rudervall J.P. Charpentier Raghuveer Sharma, High Voltage Direct Current (HVDC) Transmission Systems Technology Review
[7] Gilead, Inc., 2006a. Hazardous Materials Business Plan, 310 Lakeside Drive, Foster City, CA. June 21.
[8] Gilead, Inc., 2006b. Hazardous Materials Business Plan, 320 Lakeside Drive, Foster City, CA. November 22.
[9] Gilead, Inc., 2006c. Hazardous Materials Business Plan, 322 Lakeside Drive, Foster City, CA. June 21.
[10] Gilead, Inc., 2006d. Hazardous Materials Business Plan, 324 Lakeside Drive, Foster City, CA. June 1.
[11] Gilead, Inc., 2006e. Hazardous Materials Business Plan, 335 Lakeside Drive, Foster City, CA. April 1.
[12] Gilead, Inc., 2006f. Hazardous Materials Business Plan, 342 Lakeside Drive, Foster City, CA. April 1 Paper