Design Process of the Fixing Pipes in the Guide Pipe Anchor System for Cable-Stayed Bridges
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Design Process of the Fixing Pipes in the Guide Pipe Anchor System for Cable-Stayed Bridges

Authors: Jinwoong Choi, Sun-Kyu Park, Sungnam Hong

Abstract:

For the efficient and safe use of the cable-stayed bridge, a design based on the detailed local analysis of the cable anchor system is required. Also, a theoretical design process for the anchor system should be prepared and reviewed. Generally, the size of the fixing pipe in the anchor system is decided according to the specifications prepared by cable-manufacturing companies, and accordingly, there is difficulty determining the initial inner diameters of the fixing pipes. As such, there is no choice but to use the products with the existing sizes. In this study, the existing design process of the fixing pipe, is a type of guide pipe anchor in the cable anchor system, is reviewed, a formula determining the thickness of the fixing pipe is proposed, and the convenience and validity of the suggested equation is compared with the results of the existing designs to verify its convenience and validity.

Keywords: Cable-stayed bridge; Guide pipe anchor system; Fixing pipe; Theoretical design process.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1334688

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3313

References:


[1] CEB-FIP, Acceptance of stay cable systems using prestressing steels, 2005.
[2] Byung-Seung Kong, Ji-Ho Park, Jung-Jin Han, "A Study on Structural Analysis of Cable Anchor System for Cable-Stayed Bridge", Journal of The Korean Society of Steel Construction, 2006, pp.638-642.
[3] Byung-seung Kong, Nam-seeg Hong, "Structural Analysis of a Cable Anchor System for a Cable-Stayed Bridge over the Sea", Journal of ocean engineering and technology, Vol. 19 No.5, 2005, pp.34~42.
[4] Incheon Bridge Project, Design Package No.16 Cable-Stayed Bridge, 2006.
[5] Korea Electric Power Corporation; Construction Department (Unit1), Yeongheung Thermal Power Plant Access roads and bridges(2 points). Engineering, employment Structural & Hydraulic Calculation(Ôàá) , 1995.
[6] Korea Institute of Construction Technology, Design guidelines of Cable-Stayed Bridge with the Type of Pipe Anchor, 1997.
[7] Byung-Geon Park, "A Study on Design of Fixing Pipe in Cable Anchor System for Cable-Stayed Bridge", Sungkyunkwan University., Master's thesis, 2010.
[8] Korea Bridge Design & Engineering Research Center, Design Code of Concrete Bridge, 2010.
[9] PTI, Recommendations for stay cable design, testing and installation, 5th Edition, 2007.
[10] Japan Road Association, Specifications for Highway Bridges part2 : Steel Bridges, 2002.
[11] Ji-Ho Park, "A Study on Stress Analysis of Cable Anchor System for Cable-Stayed Bridge", Dongseo University, Master's thesis, 2007.
[12] Sung-Yoon Woon, "Numerical Analyses Studies for Fatigue Strength of Cable-Stayed Bridge girder Cable Anchorage Zones with the Type of Pipe Anchor", Dongseo University, Master's thesis, 2005.