Dynamic Response of a Water Tower Composed of Interlocked Panels
Authors: F. Gurkalo, K. Poutos
Abstract:
Earthquakes produce some of the most violent loading situations that a structure can be subjected to and if a structure fails under these loads then inevitably human life is put at risk. One of the most common methods by which a structure fails under seismic loading is at the connection of structural elements. The research presented in this paper investigates the interlock systems as a novel method for building structures. The main objective of this experimental study wasto determine the dynamic characteristics and the seismic behaviour of the proposed structures compared to conventional structural systemsduring seismic motions. Results of this study indicate that the interlock mechanism of the panels influences the behaviour of lateral load-resisting systems of the structures during earthquakes, contributing to better structural flexibility and easier maintenance.Keywords: Watertower, earthquake, seismic, interlocked panels
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1062718
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2050References:
[1] Algreane, G. A., Osman, S. A., Karim, O. and Kasa, A., 2011. Behavior of Elevated Concrete Water Tank Subjected to Artificial Ground Motion. EJGE, 16 (Bund. D), pp.387-406.
[2] Malhotra, P. K., Wenk, T. and Wieland, M., 2000. Simple Procedure for Seismic Analysis of Liquid-Storage Tanks. Structural Engineering International, 2/2000, pp. 197-201.
[3] Gareane, A.I., Algreane, G. A., Osman, S. A., Karim, O. and Kasa, A., 2011. Study the Fluid Interaction due to Dynamic Response of Elevated Concrete Water Tank. Australian Journal of Basic and Applied Science, 5(9), pp.1084-1087.
[4] El-Rakabawy, M. M., El-Arabaty, H. A. and El-Sherbiny, M. G., 2005. Response of Elevated Water Tanks to Seismic Loads. ICSGE, 11th
[5] Rai, D. C., 2002. Review of Code design Forces for Shaft Supports of Elevated Water tanks. 12th Symposium on Earthquake Engineering, pp.1407-1418.
[6] AcerMetric┬®. 2010 The AcerMetric┬® System, www.acermetric.co.uk
[7] ANSYS, INC., 2009. Ansys Workbench user-s guide.
[8] Eurocode-8, 2006. Design of structures for earthquake resistance - Part 4: Silos, tank and pipelines. European Committee for Stabilisation, Final PT Draft.
[9] Housner, G.W., 1963. The Dynamic Behaviour of Water Tanks . Bulletin of Seismological Society of America, 53(2), pp.381-387.
[10] Jain, S. K. and Jaiswal, O. R., 2005. Modified proposed provisions for aseismic design of liquid storage tanks. Journal of Structural Engineering, 32(3,4), pp.195-206, pp.297-310.
[11] Pacific Earthquake Engineering Research Center, 2011. Users Manual for the PEER Ground Motion Database Web Application.
[12] Livaoglu, R. and Dogangun, A., 2006. Simplified seismic analysisprocedures for Elevated tanks considering fluid-structure interaction. Journal of Fluids and Structures, 22, pp.421-439.