Transimpedance Amplifier for Integrated 3D Ultrasound Biomicroscope Applications
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33126
Transimpedance Amplifier for Integrated 3D Ultrasound Biomicroscope Applications

Authors: Xiwei Huang, Hyouk-Kyu Cha, Dongning Zhao, Bin Guo, Minkyu Je, Hao Yu

Abstract:

This paper presents the design and implementation of a fully integrated transimpedance amplifier (TIA) as the analog frontend receiver for Capacitive Micromachined Ultrasound Transducers (CMUTs) for ultrasound biomicroscope imaging application. The amplifier is designed to amplify the received signals from 17.5MHz to 52.5MHz with a center frequency of 35MHz. The TIA was fabricated in GF 0.18μm 1P6M 30V high voltage process. The measurement results show that the designed amplifier can reach a transimpedance gain of 61.08dBΩ and operating frequency from 17.5MHz to 100MHz with 1VP-P output voltage under 6V power supply.

Keywords: 3D ultrasound biomicroscope, analog front-end, transimpedance amplifier, CMUT

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1332408

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2726

References:


[1] P. Levesque and M. Sawan, "Novel low-power ultrasound digital preprocessing architecture for wireless display," IEEE Trans. on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 57, no.3, pp. 757-767, 2010.
[2] I. Wygant et al., "An integrated circuit with transmit beamforming flipchip bonded to a 2-D CMUT array for 3-D ultrasound imaging," IEEE Trans. on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 56, no.10, pp. 2145-2156, 2009.
[3] R. H. Silverman, "High-resolution ultrasound imaging of the eye - a review," Clin Experiment Ophthalmol, vol. 37, no.1, pp. 54-67, 2009.
[4] I. Ladabaum, X. C. Jin, H. T. Soh, A. Atalar, and B. T. Khuri-Yakub, "Surface micromachined capacitive ultrasonic transducers," IEEE Trans. on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 45, no. 3, pp. 678-690, May 1998.
[5] D. Zhao, M. T. Tan, H.-K. Cha, J. Qu, M. Yan, H. Yu, A. Basu, and M.- K. Je, "High-voltage pulser for ultrasound medical imaging applications." 13th Int. Symp. on Integrated Circuits (ISIC), pp. 408- 411, 2011.
[6] M. Fuller et. al, "Experimental system prototype of a portable, low-cost, C-scan ultrasound imaging device," IEEE Trans. on Biomedical Engineering, vol. 55, no.2, pp. 519-530, Feb. 2008.
[7] I. Wygant et al., "Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging," IEEE Trans. Ultrasonics, Ferroelectrics, and Frequency Control, vol. 55, no.2 pp. 327-342, Feb. 2008.
[8] K. Insoo, et. al., "CMOS Ultrasound Transceiver Chip for High- Resolution Ultrasonic Imaging Systems," IEEE Trans. on Biomedical Circuits and Systems, vol. 3, no. 5, pp. 293-303, 2009.
[9] G. Gurun, et. al., "Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results," IEEE Ultrasonics Symposium (IUS), pp. 390-393, 2008.