Comparison of Welding Fumes Exposure during Standing and Sitting Welder’s Position
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Comparison of Welding Fumes Exposure during Standing and Sitting Welder’s Position

Authors: Azian Hariri, M. Z. M Yusof, A. M. Leman

Abstract:

Experimental study was conducted to assess personal welding fumes exposure toward welders during an aluminum metal inert gas (MIG) process. The welding process was carried out by a welding machine attached to a Computer Numerical Control (CNC) workbench. A dummy welder was used to replicate welder during welding works and was attached with sampling pumps and filter cassettes for welding fumes sampling. Direct reading instruments to measure air velocity, humidity, temperature and particulate matter with diameter size 10µm or less (PM10) were located behind the dummy welder and parallel to the neck collar level to make sure the measured welding fumes exposure were not being influenced by other factors. Welding fumes exposure during standing and sitting position with and without the usage of local exhaust ventilation (LEV) was investigated. Welding fume samples were then digested and analyzed by using inductively coupled plasma mass spectroscopy (ICP-MS) according to ASTM D7439-08 method. The results of the study showed the welding fume exposure during sitting was lower compared to standing position. LEV helped reduce aluminum and lead exposure to acceptable levels during standing position. However during sitting position reduction of exposure was smaller. It can be concluded that welder position and the correct positioning of LEV should be implemented for effective exposure reduction. 

Keywords: ICP-MS, MIG process, personal sampling, welding fumes exposure.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1088284

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2612

References:


[1] H.S. Ashby, "Welding fumes in the workplace: Preventing potential health problems through proactive controls," Professional Safety, pp. 55- 60, 2002.
[2] S.R. Fiore, "Reducing exposure to hexavalent chromium in welding fumes," Welding Journal, pp. 38-43, 2006.
[3] E. Ravert ,"Controlling chromium fumes," Welding Journal, 2006.
[4] C. Isaxon, J. Pagels, A. Gudmundsson, C. Asbach, A.C. John, T.A.J. Kuhlbusch, J.E. Karlsson, R. Kammer, H. Tinnerberg, J. Nielsen and M. Bohgard, "Characteristics of welding fume aerosol investigated in three Swedish workshops," Journal of Physics: Conference Series 151, 2009.
[5] Malaysia Factories and Machinery Act (Act 139), Kuala Lumpur : MDC Publisher Sdn. Bhd., 2010.
[6] Malaysia Occupational Safety and Health Act (Act 514), Kuala Lumpur: MDC Publisher Sdn. Bhd., 2010.
[7] J. Blunt and N.C. Balchin, Health and Safety in Welding and Allied Processes, Cambridge: Woodhead Publishing Limited, 2000.
[8] P.J. Hewitt, "Strategies for risk assesment and control in welding: challenges for developing countries, "Ann. Occup.Hyg., vol. 45 pp. 295- 298, 2001.
[9] J.M. Antonini, A.A. Afshari, S. Stone, B. Chen, D. Schwegler-Berry, W.G. Fletcher, W.T. Goldsmith, K.H. Vandestouwe, W. McKinney, V. Castranova and D.G. Frazer, " Design, construction, and characterization of a novel robotic welding fume generator and inhalation exposure system for laboratory animals," Journal of Occupational and Environmental Hygiene,vol. 3, pp.194-203, 2006.
[10] N.T. Jenkins and T.W. Eager, "Chemical analysis of welding fume particles," Welding Journal, pp. 87-93, June 2005.
[11] B. Moroni and C. Viti, "Grain size, chemistry, and structure of fine and ultrafine particles in stainless steel welding fumes," Journal of Aerosol Science, vol. 40, pp. 938-949, 2009.
[12] G.R. Liden and J. Surakka, " A headset-mounted mini sampler for measuring exposure to welding aerosol in the breathing zone," Annals of Occupational Hygiene, vol. 53, pp.99-116, 2009.
[13] J. Ojima, " Laboratory evaluation of carbon monoxide exposure in carbon dioxide arc welding," J. Occup Health, vol. 51, pp. 377-379, 2009.
[14] F.W. Boelter, C.E. Simmons, L. Berman and P. Scheff , "Two-zone model application to breathing zone and area welding fume concentration data," Journal of Occupational and Environmental Hygiene, vol. 6, pp. 298 - 306, 2009.
[15] E. Kiesswetter, M. Schäper, M. Buchta, K. Schaller, B. Rossbach, H. Scherhag, W. Zschiesche and S. Letzel, " Longitudinal study on potential neurotoxic effects of aluminium: I. Assessment of exposure and neurobehavioural performance of Al welders in the train and truck construction industry over 4 years," International Archives of Occupational and Environmental Health, vol. 81 (pp. 41-67, 2007.
[16] E. Kiesswetter, M. Schäper, M. Buchta, K. Schaller, B. Rossbach, T. Kraus and S. Letzel, " Longitudinal study on potential neurotoxic effects of aluminium: II. Assessment of exposure and neurobehavioral performance of Al welders in the automobile industry over 4 years, " International Archives of Occupational and Environmental Health, vol. 82, pp. 1191-1210, 2009.
[17] S. Liu and S.K. Hammond, "Mapping particulate matter at the body weld department in an automobile assembly plant," Journal of Occupational and Environmental Hygiene, vol. 7, pp. 593 - 604, 2010.
[18] Z. Loukzadeh, S.A. Sharifian, O. Aminian and A. Shojaoddiny- Ardekani, "Pulmonary effects of spot welding in automobile assembly," Occupational Medicine, vol. 59, pp. 267-269, 2009.
[19] J.C.J. Luo, K.H. Hsu and W.S. Shen, " Pulmonary function abnormalities and airway irritation symptoms of metal fumes exposure on automobile spot welders," American Journal of Industrial Medicine, vol. 49, pp. 407-416, 2006.
[20] J.-C.J. Luo, K.-H. Hsu and W.-S. Shen, " Inflammatory responses and oxidative stress from metal fume exposure in automobile welders," Journal of Occupational and Environmental Medicine, vol. 51, pp. 95- 103, 2009.
[21] N. Mansouri, F. Atbi, N. Moharamnezhad, D.A. Rahbaran and M. Alahiari, "Gravimetric and analytical evaluation of welding fume in an automobile part manufacturing factory," J.Res. Health Sci., vol. 8, pp. 1- 8, 2008.
[22] D.H. Brouwer, J.H.J. Gijsbers and M.W.M. Lurvink, "Personal exposure to ultrafine particles in the workplace: Exploring sampling techniques and strategies, Annals of Occupational Hygiene, vol. 48, pp. 439-453, 2004.
[23] D.E. Evans, W.A. Heitbrink, T.J. Slavin and T.M. Peters ,"Ultrafine and respirable particles in an automotive grey iron foundry," Annals of Occupational Hygiene, vol. 52, pp. 9-21, 2008.
[24] P.-J. Tsai and J.H. Vincent, " A study of workers exposures to the inhalable and total aerososl fractions in the primary nickel production industry using mannequins to simulate personal sampling," Ann. Occup.Hyg., vol. 45, pp. 385-394, 2001.
[25] A. Hariri, A.M. Leman and M.Z.M. Yusof, "Application of Malaysian anthropometric data in dummy welder design," in Proc. International Conference on Design and Concurrent Engineering, Melaka, Malaysia, 2012, pp. 20-24.
[26] NIOSH U.S.A, NIOSH Analytical Method 7300: Elements by ICP, 2003.
[27] ASTM , Determination of Elements in Airborne Particulate Matter by Inductively Coupled Plasma-Mass Spectrometry, 2008.
[28] British Standard, BS-ISO 30011:2010 Workplace Air-Determination of Metals and Metalloids in Airborne Particulate Matter by Inductively Coupled Plasma Mass Spectrometry, 2010.