An acoustic emission (AE) technique is useful for detection of partial discharges (PDs) at a joint and a terminal section of a cross-linked polyethylene (XLPE) cable. For AE technique, it is not difficult to detect a PD using AE sensors. However, it is difficult to grasp whether the detected AE signal is owing to a single discharge or not. Additionally, when an AE technique is applied at a terminal section of a XLPE cable in salt pollution district, for example, there is possibility of detection of AE signals owing to creeping discharges on the surface of electric power apparatus. In this study, we evaluated AE signals in order to grasp what kind of information we can get from detected AE signals. The results showed that envelop detection of AE signal and a period which some AE signals were continuously detected were good indexes for estimating state-of-discharge.Keywords: acoustic emission, creeping discharge, partial discharge, XLPE cable
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1084846
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1647References:
[1] T. Sakoda, T. Arita, H. Nieda, K. Ando, M. Otsubo, and C. Honda, "Studies of Elastic Waves Caused by Corona Discharge in Oil", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 6, No.6, pp. 825-830, Dec. 1999.
[2] Y. Tian, P. L. Lewin, A. E. Davies, and Z. Richardson, "Acoustic Emission Detection of Partial Discharges in Polymeric Insulation", High Voltage Engineering Symposium, Conference Publication, No. 467, pp. 1.82.S23-1.85.S23, 1999.
[3] B. T. Phung, R. E. James, T. R. Blackbum, and Q. Su, " Partial discharge ultrasonic wave propagation in steel transformer tanks", 7th International Symposium on High Voltage Engineering, pp. 131-134, 1991.
[4] T. Sakoda, H. Nieda, and K. Ando, "Characteristics of Elastic Waves Caused by Corona Discharges in an Oil-immersed Pole Transformer", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 8, No.2, pp. 276-283, Apr. 2001.
[5] R. T. Harrold, "Acoustical Technology Applications In Electrical Insulation And Dielectrics", IEEE Transactions on Electrical Insulation, Vol.20, pp.3-19, 1985.
[6] Masanori Takaoka, Tatsuya Sakoda, Masahisa Otsubo, Shigeru Akaiwa, Masatoshi Iki, and Shigeharu Nakano, "Studies of Elastic Waves in Ethylene Propylene Rubber Using Acoustic Emission Sensor", IEEJ Trans. FM, Vol. 128, No. 10, pp.641-645, Oct. 2008.
[7] H. Borsi, "Digital Location of Partial Discharges in HV Cables", IEEE Trans. on Electrical Insulation, Vol. 27, No. 1, pp. 28-36, 1992.
[8] Tatsuya Sakoda, Toshihiko Nakashima, Masahisa Otsubo, Satoshi Kurihara, Shinya Nagasato, and Takayoshi Yarimitsu: "Diagnostics of Insulation Deterioration of Ethylene Propylene Rubber Using an Acoustic Emission Technique", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 17, No. 4, pp.1242-1248, 2010.
[9] Takuya Yamamoto, Toshihiko Nakashima, Tatsuya Sakoda, Masahisa Otsubo, Satoshi Kurihara, Shinya Nagasato, Takayoshi Yarimitsu: "Studies on Acoustic Emission Signals Detected in an Oil-immersed Pole Transformer, Institute of Electrical Engineers of Japan Transactions on Electrical and Electronic Engineering, Vol. 130, No. 11, pp. 1031-1036, 2010.