Abstract:

The heat storage capacity of concrete in building shells is a major reason for excessively large electricity consumption induced by indoor air conditioning. In this research, the previously developed Smart Temperature Information Material (STIM) is embedded in two groups of exterior wall specimens (the control group contains reinforced concrete exterior walls and the experimental group consists of tiled exterior walls). Long term temperature measurements within the concrete are taken by the embedded STIM. Temperature differences between the control group and the experimental group in walls facing the four cardinal directions (east, west, south, and north) are evaluated. This study aims to provide a basic reference for the design of exterior walls and the selection of heat insulation materials.

Keywords: building envelope, sensor, energy, thermal insulation, reinforced concrete

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1080604

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1599

References:


[1] The Institute of Energy Economics, Japan, http://eneken.ieej.or.jp/en/ (accessed on 9 October 2011).
[2] J. L. Alvarado, W. Terrell, and M. D. Johnson, "Passive cooling systems for cement-based roofs,"Build. Environ., vol.44, no. 9, pp. 1869-1875, Sep. 2009.
[3] H. T. Lin, Energy efficiency design of building envelopes and Strategies for reducing CO2 emission, Architecture and Building Research Institute, Ministry of the Interior, 2007. pp. 15-34.
[4] D. C. Chou and J. J. Chiou, "A Study on the Insulation Performance of a Double Skin Roof Induced by Natural Ventilation," Journal of Architecture, no.59, pp.79-92, 2007.
[5] K. C. K. Vijaykumar, P.S.S. Srinivasan, and S. Dhandapani, "A performance of hollow clay tile (HCT) laid reinforced cement concrete (RCC) roof for tropical summer climates,"Energy Build., vol. 39, no. 8, pp. 886-892, Aug. 2007.
[6] A. Praditsmanont, and S. Chungpaibulpatana, "Performance analysis of the building envelope: A case study of the Main Hall, Shinawatra University," Energy Build., vol.40, no. 9, pp.1737-1746, 2008.
[7] C. Y. Chang, W. H. Hsiao, S. M. Huang, and S. J. Guo, "Supply and Demand for Building Health Check,"Journal of Architecture, no.59, pp.93-112, 2007.
[8] C. Y. Chang, and S. S. Hung, "Implementing RFIC and sensor technology to measure temperature and humidity inside concrete structures," Constr. Build. Mater., vol. 26, no. 1, pp. 628-637, Jan. 2012.
[9] C. Y. Chang, S. S. Hung, Y. F.Peng, W. T. Chang, and H. Y.Feng, "Building Physiology Information System for Health Monitoring in Reinforced Concrete Structures", Intelligent Buildings International, DOI:10.1080/17508975.2011.642477
[10] C. Y. Chang, S. S. Hung and Y. F. Peng, "An Evaluation of the Embedment of a Radio Frequency Integrated Circuit with a Temperature Detector in Building Envelopes for Energy Conservation," Energy Build., vol. 43, no. 10, pp.2900-2907, Oct. 2011.
[11] X. L. Zhao, T. Qian, G. Mei, C. Kwan, R. Zane, C. Walsh, T. Paing, and Z. Popovic, "Active health monitoring of an aircraft wing with an embedded piezoelectric sensor/actuator network: II Wireless approaches,"Smart Mater. Struct., vol.16, no. 4, pp. 1218-1225, Aug. 2007.
[12] K. Crowley, J. Frisby, S. Murphy, M. Roantree, and D. Diamond, "Web-based real-time temperature monitoring of shellfish catches using a wireless sensor network," Sens. Actuator A-Phys., vol. 122, no. 2, pp. 222-230, Aug. 2005.
[13] J. Wu, S. F. Yuan, S. Ji, G.Y. Zhou, Y. Wang, and Z. L. Wang, "Multi-agent system design and evaluation for collaborative wireless sensor network in large structure health monitoring,"Expert Syst. Appl., vol. 37, no. 3, pp. 2028-2036, Mar. 2010.
[14] N. Andre, S. Druart, P. Gerard, R. Pampin, L. Moreno-Hagelsieb, T. Kezai, L.A. Francis, D. Flandre, J.P. Raskin, "Miniaturized Wireless Sensing System for Real-Time Breath Activity Recording," IEEE Sens. J., vol. 10, no. 1, pp. 178-184, Jan. 2010.
[15] R. U. Halwatura, and M.T.R. Jayasinghe, "Thermal performance of insulated roof slabs in tropical climates," Energy Build., vol. 40, no. 7, pp. 1153-1160, 2008.
[16] F. Stazi, C. Di Perna, and P. Munafo, "Durability of 20-year-old external insulation and assessment of various types of retrofitting to meet new energy regulations," Energy Build., vol. 41, no. 7, pp. 721-731, Jul. 2009.
[17] S. A. Al-Ajlan, "Measurements of thermal properties of insulation materials by using transient plane source technique," Appl. Therm. Eng., vol. 26, no. 17-18, pp. 2184-2191, Dec. 2006.
[18] H. L. Zhang, W. M. Marci, and X. Z. Fu," Modeling of the hydrothermal absorption and desorption for underground building envelopes," Energy Build., vol. 42, no. 8, pp. 1215-1219, Aug. 2010.