Experimental and Numerical Investigation of Air Ejector with Diffuser with Boundary Layer Suction
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Experimental and Numerical Investigation of Air Ejector with Diffuser with Boundary Layer Suction

Authors: Vaclav Dvorak

Abstract:

The article deals with experimental and numerical investigation of axi-symmetric subsonic air to air ejector with diffuser adapted for boundary layer suction. The diffuser, which is placed behind the mixing chamber of the ejector, has high divergence angle and therefore low efficiency. To increase the efficiency, the diffuser is equipped with slot enabling boundary layer suction. The effect of boundary layer suction on flow in ejector, static pressure distribution on the mixing chamber wall and characteristic were measured and studied numerically. Both diffuser and ejector efficiency were evaluated. The diffuser efficiency was increased, however, the efficiency of ejector itself remained low.

Keywords: Air ejector, boundary layer suction, CFD, diffuser.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1080080

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2818

References:


[1] J. H. Keenan, E. P. Neumann and F. Lustwerk, "An Investigation of Ejector Design by Analysis and Experiment," Journal of Applied Mechanics, Trans ASME, 1950, 72, pp. A75-A81.
[2] D. W. Sun and I. W. Eames, "Recent Developments in the Design Theories and Applications of Ejectors - a review," Journal of the Institute of Energy, 1995, pp. 65-79.
[3] J. L. Porter, R. A. Squyers, "A Summary/Overview of Ejector Augmentor Theory and Performance," ATC Report No. R-91100/9CR- 47A, Vought Corpn Advanced Technology Cr, Dallas, Texas, 1981.
[4] D. Japikse, N. C. Baines, Diffuser Design Technology, Concepts ETI, Inc., USA 1998.
[5] Y. Furuya, T. Sato, T. Kushida, "The loss of flow in the conical diffusers with suction at the entrance," Bull JSME 9(33). 1966, pp. 133-136.
[6] T. T. Yang, W. G. Hudson, C. D. Nelson, "Design and experimental performance of short curved wall diffusers with axial symmetry utilizing slot suction," NASA CR-2209. 1973.
[7] D. O. Rockwell, "Flow fields in a two-dimensional diffuser with extraction of fluid on the diverging walls," Trans ASME Journ Eng Power 94, 1972, pp. 226-232.
[8] R. E. Anderson, "The effect of boundary layer suction on the efficiency of the diffuser of a jet ejector," Thesis, The University of Texas, 1958.
[9] B. S. Riffat, G. Gan, S. Smith, "Computational Fluid Dynamics Applied to Ejector Heat Pumps," Applied Thermal Engineering Vol. 16, No. 4, 1996, pp. 291-297.
[10] E. Rusly, Lu Aye, W. W. S. Charters, A. Ooi, "CFD Analysis of Ejector in a Combined Ejector Cooling System," International Journal of Refrigeration 28, 2005, pp. 1092-1101.
[11] V. Dvorak, "Optimized Axi-Symmetric Ejector - Experimental and Numerical Investigation," Experimental Fluid Mechanics 2009, Liberec 25. - 27. November 2009, pp. 34-43.
[12] Y. Bartosiewicz, Z. Aidoun, P. Desevaux, Y. Mercadier, "Numerical and experimental investigations on supersonic ejectors," International Journal of Heat and Fluid Flow 26 (2005), pp. 56-70.
[13] J. Simak, "Computation of the Flow and Interaction of Shock Waves in a 2D Supersonic Ejector", Colloquium Fluid Dynamics 2009, Institute of Thermomechanics AS CR, v.v.i., Prague, Czech Republic, October 21 - 23, 2009.
[14] V. Dvorak, "Air ejector with diffuser with boundary layer suction", to be published in Engineering Mechanics, Brno, Czech Republic, 2013.
[15] V. Dvorak, P. Dancova, "An Investigation into Air Ejector with Pulsating Primary Flow", World Academy of Science, Engineering and Technology, issue 81, September 2011, pp. 601-607.