Integrated Wastewater Reuse Project of the Faculty of Sciences Ain Chock, Morocco
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Integrated Wastewater Reuse Project of the Faculty of Sciences Ain Chock, Morocco

Authors: Nihad Chakri, Btissam El Amrani, Faouzi Berrada, Fouad Amraoui

Abstract:

In Morocco, water scarcity requires the exploitation of non-conventional resources. Rural areas are under-equipped with sanitation infrastructure, unlike urban areas. Decentralized and low-cost solutions could improve the quality of life of the population and the environment. In this context, the Faculty of Sciences Ain Chock (FSAC) has undertaken an integrated project to treat part of its wastewater using a decentralized compact system. The project will propose alternative solutions that are inexpensive and adapted to the context of peri-urban and rural areas in order to treat the wastewater generated and to use it for irrigation, watering and cleaning. For this purpose, several tests were carried out in the laboratory in order to develop a liquid waste treatment system optimized for local conditions. Based on the results obtained at laboratory scale of the different proposed scenarios, we designed and implemented a prototype of a mini wastewater treatment plant for the faculty. In this article, we will outline the steps of dimensioning, construction and monitoring of the mini-station in our faculty.

Keywords: Wastewater, purification, response methodology surfaces optimization, vertical filter, Moving Bed Biofilm Reactors, MBBR process, sizing, prototype, Faculty of Sciences Ain Chock, decentralized approach, mini wastewater treatment plant, reuse of treated wastewater reuse, irrigation, sustainable development.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 282

References:


[1] CESE, “Rapport Annuel 2019,” 2019.
[2] SNDD, “Stratégie nationale de développementt durable: 2016- 2030,” Rabat, 2017.
[3] Conseil Economique Social et Environnemental, “La gouvernance par la gestion integrée des ressources en eau au Maroc: Livier fondamental de développement durable,” Rabat, Maroc, Auto-saisine AS n°15 / 2014, 2014.
[4] Secrétariat d’Etat chargé du développement durable, “Plan national d’assainissement liquide (PNA),” Rabat, 2005.
[5] Secrétariat d’Etat chargé du développement durable- Ministère de l’Intérieur- Ministère d’économie et de Finance, “Programme National d’Assainissement Liquide,” Rabat, Maroc, 2019.
[6] Secrétariat d’Etat chargé du développement durable, “Stratégie nationale de l’eau,” Rabat, 2018.
[7] B. El Hamouri, Réacteur anaérobie et chenal à haut rendement: pour l’épuration des eaux usées des petites communautés. Rabat: Institut Agronomique et Vétérinaire Hassan II, 2004.
[8] Y. Salama, “Traitement des eaux usées domestiques par un lit bactérien dénitrifiant immergé,” Université Chouaïb Doukkali- Faculté des Sciences El Jadida, 2014.
[9]
[9] A. Saidi, B. Elamrani, and F. Amraoui, “Mise en place d’un filtre planté pour le traitement des eaux usées d’un Hammam et leur réutilisation dans l’irrigation d’une ferme solidaire dans le périurbain Casablancais,” Mater. Environ. Sci., vol. 5, no. 2028–2508, pp. 2184–2190, 2014.
[10] N. Chakri, B. El Amrani, F. Berrada, and F. Amraoui, Study of wastewater treatment’s scenarios of the Faculty of Sciences- Ain Chock, Casablanca Proposal I: vertical flow filter, AI2SD 2018., vol. 1. Tanger: Springer International Publishing, 2019.
[11] N. Chakri, B. El Amrani, F. Berrada, H. Nourredine, and F. Byoud, “Optimization of the wastewater treatment of the Faculty of Sciences Ain Chock by an MBBR process,” in International Conference on Energy and Environment and Storage of Energy ICEESEN 2020, 2020, pp. 483–487.
[12] N. Chakri, B. El Amrani, and F. Berrada, “Modeling and optimization of wastewater treatment, from the ain chock faculty in morocco, using the vertical flow filter filled with pozzolana,” Desalin. Water Treat., vol. 234, pp. 376–385, 2021.
[13] N. Chakri, “Implémentation et évaluation du fonctionnement d’une filière décentralisée pour l’épuration des eaux usées de la faculté des sciences Ain Chock ‘FSAC’. Étude de son application application pour un hammam périurbain dans la commune de Dar Bouazza (Casablan,” University Hassan II of Casablanca- Morocco, 2021.
[14] SPGE, “Guide de mise en oeuvre d’un système d’épuration individuelle,” Wallonie, France, 2019.
[15] S. Reuter, B. Gutterer, L. Sasse, and T. Panzerbieter, Decentralised Wastewater Treatment Systems (DEWATS) and Sanitation in Developing Countries, vol. 49, no. 0. Water, Engineering and Development Centre (WEDC), Loughborough University, UK, in association with Bremen Overseas Research (BORDA), Germany, 2009.
[16] N. S. Reynaud, “Operation of decentralised wastewater treatment systems (DEWATS) under tropical field conditions,” Technical University, Dresden., 2014.
[17] L. Chaaibi and F. Berrada, “Dimensionnement de la station d’épuration, à filtre planté, de la Faculté des Sciences Ain Chock.,” Casablanca, 2013.
[18] Arrêté du Gouvernement wallon, Fixant les conditions intégrales et sectorielles relatives aux systèmes d’épuration individuelle. 2016, p. 11.
[19] A. Saidi, “Approche décentralisée pour une gestion efficace des eaux usées : cas d’études à Casablanca et à Berlin,” Université Hassan II- Faculté des Sciences Ain Chock- Casablanca, 2016.
[20] N. Chakri, B. El Amrani, F. Berrada, and H. Jounaid, “Environmental diagnosis of traditional hammams of Dar Bouazza’s Commune, Morocco,” Desalin. Water Treat., vol. 170, 2019.
[21] Agence de l’eau Rhin-Meuse, “Les procédés d’épuration des petites collectivités du bassin Rhin-Meuse: éléments de comparaison techniques et économiques,” France, 2007.
[22] R. Franceys, J. Pickford, and R. Reed, Guide de l’assainissement individuel. Suisse, 1995.
[23] R. Bourrier, M. Satin, and B. Selmi, Guide technique pourl’assinaissement: cellete- épuration- conception- exploitation, 5ème éditi. Groupe Moniteur, 2017.
[24] AFNOR, NF P20-101: Portes et blocs portes - caractéristiques dimensionnelles. France, 2011, p. 31.
[25] IRSTEA- SIEAM, “Cahier des prescriptions techniques: station d’épuration type Filtres plantés à écoulement vertical,” Mayotte, 2015.
[26] R. L. Lombard and P. Molle, “Les filtres plantés de végétaux pour le traitement des eaux usées domestiques en milieu tropical - guide de dimensionnement de la filière tropicalisée,” France, 2017.
[27] A. Reuillon, L. Vasseur, and P. Molle, “Filtre à écoulement vertical, non saturé- saturé,” Action 40-2, 2015.
[28] N. melet et coll Jean Rodier, Bernard Legube, L’analyse de l’eau, 9e Edition. Paris, France, 2009.
[29] Association française de normalisation (AFNOR), Recueils des normes AFNOR, Tomes 1 à 4. 1999.
[30] Bulletin officiel N° 5448, Fixation des valeurs limites spécifiques de rejet domestique, vol. 1427, no. 12. ministre de l’intérieur, du ministre de l’aménagement du territoire, de l’eau et de l’environnement et du ministre de l’industrie, du commerce et de la mise à niveau de l’économie, 2006, p. 2.
[31] ONEP, “Approche de la typologie des eaux usées urbaines au Maroc,” Rabat, 1998.
[32] “Arrete conjoint du ministre de l’equipement et du ministre charge de l’amenagement du territoire, de l’environnement, de l’urbanisme et de l’habitat n° 1276‐01 du 17 octobre 2002portant fixation des normes de qualite des eaux destinees a l’irrigation,” Bull. Off., vol. N° 1276‐01, pp. 1–5, 2002.
[33] Bulletin officiel N°1276-01, Fixation des normes de qualité des eaux destinées à l’irrigation, vol. 1423, no. 1. Ministre de l’équipement et du ministre chargé de l’aménagement du territoire, de l’urbanisme, de l’habitat et de l’environnement, 2002, p. 5.
[34] P. Dodane and M. Bassan, “Bassins de décantation et d’épaississement,” in TECHNOLOGIE, 2015, pp. 131–150.
[35] M. Mujawamaria, “Optimisation de la décantation primaire par ajout de produits chimiques – Jar-Tests,” Quebec, Canada, 2012.
[36] The Cadmus Group, “Nutrient control design manual: state of technology review report,” 2009.
[37] I. Chaouki, L. Mouhir, S. Souabi, and M. Fekhaoui, “Étude de la performance de la STEP du centre emplisseur de la société Salam Gaz – Skhirat, Maroc Résumé,” Afrique Sci. Rev. Int. des Sci. Technol., vol. 09, no. 3, pp. 91–102, 2013.
[38] T. Sovana, “Optimisation des unités de décantation primaire des stations d’épuration de la ville de Québec,” 2010.
[39] J.-P. Canler and J. M. Perret, “La décantation lamellaire des boues activées,” 1994.
[40] U. Barry, “Comportement du procédé R3F en nitrification: suivi, modélisation dynamique et limites du procédé,” Institut des Sciences et Industries du Vivant et de l’Environnement (AgroParisTech), 2013.
[41] A. H. Javid, A. H. Hassani, B. Ghanbari, and K. Yaghmaeian, “Feasibility of utilizing moving bed biofilm reactor to upgrade and retrofit municipal wastewater treatment plants,” Int. J. Environ. Res., vol. 7, no. 4, pp. 963–972, 2013.
[42] J. Rochard, E. Marengo, D. Marengo, J.-L. Mangiacotti, and A. Joubert, “Ecoconception des caves: réduction de la consommation d’énergie et intégration paysagère du traitement des effuents de cave avec le dispositif de lit planté de roseaux sur support de zéolithe Zeofito,” BIO Web Conf., vol. 15, no. 02002, pp. 1–10, 2019.
[43] P. Moretti, “Performances, modélisation et limites d’un procédé à lit fluidisé associant culture libre et fixée (IFAS) pour le traitement du carbone et de l’azote des eaux résiduaires,” Université Claude Bernard- Lyon, 2015.
[44] UMVF, “Croissance des bactéries,” 2014.
[45] OMS, Lignes directrices pour l’utilisation des eaux usées municipales dans la région méditerranéenne. Athène: Programme des Nations Unies pour l’environnement, 2005, p. 73.
[46] R. Schubert, M. Boulestreau, M. Christensson, and B. Lesjean, “Novel wastewater process scheme for maximum COD extraction: high load MBBR followed by microsieve filtration,” in The 9th International Conference on Biofilm Reactors, 2013, p. 8.
[47] D. V. Minegatti de Oliveira, M. D. Rabelo, and Y. N. Nariyoshi, “Evaluation of a MBBR (Moving Bed Biofilm Reactor) pilot plant for treatment of pulp and paper pill wastewater,” Int. J. Environ. Monit. Anal., vol. 2, no. 4, pp. 220–225, 2014.
[48] A. Saidi, K. Masmoudi, E. Nolde, B. El Amrani, and F. Amraoui, “Organic matter degradation in a greywater recycling system using a multistage moving bed biofilm reactor (MBBR),” Water Sci. Technol., vol. 76, no. 12, pp. 3328–3339, 2017.
[49] A. Cébron, “Nitrification, bactéries nitrifiantes et émissions de N2O,” Université Paris VI – Pierre et Marie Curie, 2004.
[50] A. Zafarzadeh, B. Bina, M. Nikaeen, H. Movahedian Attar, and M. Hajian Nejad, “Performance of moving bed biofilm reactors for biological nitrogen compounds removal from wastewater by partial nitrification-denitrification,” Iran. J. Environ. Heal. Sci. Eng., vol. 7, no. 4, pp. 353–364, 2010.
[51] L. Boudreau, S. Cloutier, and I. Guay, “Position technique sur le rejet d’eaux chlorées dans le milieu aquatique,” Québec, 2009.
[52] S. Vandermeersch, “Etude comparative de l’efficacité des traitements d’épuration des eaux usées pour l’élimination des micro-organismes pathogènes,” 2006.