Heat Recovery System from Air-Cooled Chillers in Iranian Hospitals
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33103
Heat Recovery System from Air-Cooled Chillers in Iranian Hospitals

Authors: Saeed Vahidifar, Mohammad Nakhaee Sharif, Mohammad Ghaffari

Abstract:

Few people would dispute the fact that one of the most common applications of energy is creating comfort in buildings, so it is probably true to say that management of energy consumption is required due to the environmental issues and increasing the efficiency of mechanical systems. From the geographical point of view, Iran is located in a warm and semi-arid region; therefore, air-cooled chillers are usually used for cooling residential buildings, commercial buildings, medical buildings, etc. In this study, a heat exchanger was designed for providing laundry hot water by utilizing condenser heat lost base on analytical results of a 540-bed hospital in the city of Mashhad in Iran. In this paper, by using the analytical method, energy consumption reduces about 13%, and coefficient of performance increases a bit. Results show that this method can help in the management of energy consumption a lot.

Keywords: Energy management, air-cooled chiller, heat exchanger, hospital laundry system.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 928

References:


[1] Krunal R. Meshram, Prashant R. Mahale, Tushar S. Jadhav, and Mandar M. Lele “Review on Waste Heat Recovery Techniques in Air Conditioning Application” International Journal of Current Engineering and Technology,- E-Issn 2277 – 4106, P-Issn 2347 – 5161 -2016.
[2] Win-Jet Luo, Hung-Chuan Kuo, Jyun-YiWu, and Dini Faridah “Development and analysis of a new multi-function heat recovery split air conditioner with a parallel refrigerant pipe”, Advances in Mechanical Engineering, Vol. 8(10) 1–12, 2016.
[3] Luigi Schibuola, “Experimental analysis of a condenser heat recovery in an air conditioning plant” International Journal of Energy, vol24, P273–283, 1999.
[4] A. Anwaar, N. Prashant, Prof. S.B. Patil, G. Priyanka “Design and Development of a Waste Heat Recovery Unit for Household Refrigerator System” International Research Journal of Engineering and Technology, Vol6, 11 Nov, E-Issn: 2395-0056, 2019.
[5] Amir Abdullah Muhamad Damanhuri, Muhammad Ilman Hakimi Chua Abdullah, Abdul Munir Hidayat Shah Lubis, Muhammad Zulfattah Zakaria, Mohamed Saiful Firdaus Hussin, and Mohammad ‘Afif Kasno “ Development of TEG Peltier Device for Heat Harvesting from 1.5 HP Split Unit Air Conditioning System” International Journal of Applied Engineering Research Vol 13, Num5, pp. 2390-2394, Issn 0973-4562, 2018.
[6] Agnieszka Zając “Use of waste heat recovery from refrigeration system in a commercial facility – a case study” E3S Web of Conferences 116, 00103 Asee19, 2019.
[7] Lian Zhang, and Yu Feng Zhang, “Research on Heat Recovery Technology for Reducing the Energy Consumption of Dedicated Ventilation Systems: An Application to the Operating Model of a Laboratory” Energies, 2016, doi: 10.3390/en9010024
[8] M. Joseph Stalin, S. Mathana Krishnan, G. Vinoth Kumar, ”Efficient usage of waste heat from air conditioner” International Journal of Advances in Engineering & Technology, July 2012.
[9] S. Shivaji Ghadge, V.N. Kapatkar “Heat Recovery Analysis of Window Air Conditioner” -3182, Volume -4, Issue-1, Issn: 2319, 2015.
[10] Qi Xu, Saffa Riffat and Shihao Zhang, "Review of Heat Recovery Technologies for Building Applicant” Energies, 12, 1285; doi: 10.3390/en12071285, 2019.
[11] S. C. Walawade, B.R. Barve, P. R. Kulkarni “Design and Development of Waste Heat Recovery System for Domestic Refrigerator”, Journal of Mechanical and Civil Engineering Issn: 2278-1684, PP: 28-32.
[12] Lei Wang, Yasuko Sakurai,; Steven J. Bowman; David E. Claridge, “Commissioning an Existing Heat Recovery Chiller System” Ashrae journal, December 2018.