Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32759
Influence of Displacement Amplitude and Vertical Load on the Horizontal Dynamic and Static Behavior of Helical Wire Rope Isolators

Authors: Nicolò Vaiana, Mariacristina Spizzuoco, Giorgio Serino

Abstract:

In this paper, the results of experimental tests performed on a Helical Wire Rope Isolator (HWRI) are presented in order to describe the dynamic and static behavior of the selected metal device in three different displacements ranges, namely small, relatively large, and large displacements ranges, without and under the effect of a vertical load. A testing machine, allowing to apply horizontal displacement or load histories to the tested bearing with a constant vertical load, has been adopted to perform the dynamic and static tests. According to the experimental results, the dynamic behavior of the tested device depends on the applied displacement amplitude. Indeed, the HWRI displays a softening and a hardening stiffness at small and relatively large displacements, respectively, and a stronger nonlinear stiffening behavior at large displacements. Furthermore, the experimental tests reveal that the application of a vertical load allows to have a more flexible device with higher damping properties and that the applied vertical load affects much less the dynamic response of the metal device at large displacements. Finally, a decrease in the static to dynamic effective stiffness ratio with increasing displacement amplitude has been observed.

Keywords: Base isolation, earthquake engineering, experimental hysteresis loops, wire rope isolators.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1128861

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1256

References:


[1] M. L. Tinker and M. A. Cutchins, “Damping phenomena in a wire rope vibration isolation system,” Journal of Sound and Vibration, vol. 157, no. 1, pp. 7-18, 1992.
[2] G. F. Demetriades, M. C. Constantinou and A. M. Reinhorn, “Study of wire rope systems for seismic protection of equipment in buildings,” Engineering Structures, vol. 15, no. 5, pp. 321-334, 1993.
[3] G. Serino, F. Bettinali and G. Bonacina, “Seismic base isolation of gas insulated electrical substations: comparison among different solutions,” Proceedings of the 4th US Conference on Lifeline Earthquake Engineering, San Francisco, California, 1995.
[4] G. Serino, G. Bonacina and F. Bettinali, “Passive protection devices for high-voltage equipment: design procedures and performance evaluation,” Proceedings of the 4th US Conference on Lifeline Earthquake Engineering, San Francisco, California, 1995.
[5] M. Di Donna and G. Serino, “Base isolation of high-voltage equipment: comparison between two different solutions,” Proceedings of the 7th International Conference on Probabilistic Methods Applied to Power Systems, Napoli, Italy, 2002.
[6] S. Alessandri, R. Giannini, F. Paolacci and M. Malena, “Seismic retrofitting of an HV circuit breaker using base isolation with wire ropes. Part 1: Preliminary tests and analyses,” Engineering Structures, vol. 98, pp. 251-262, 2015.
[7] G. De Canio, “Marble devices for the base isolation of the two bronzes of Riace: a proposal for the David of Michelangelo,” Proceedings of the 15th Word Conference on Earthquake Engineering, Lisbon, Portugal, 2012.
[8] S. Alessandri, R. Giannini, F. Paolacci, M. Amoretti and A. Freddo, “Seismic retrofitting of an HV circuit breaker using base isolation with wire ropes. Part 2: Shaking-table test validation,” Engineering Structures, vol. 98, pp. 263-274, 2015.
[9] S. Pagano, M. Russo, S. Strano and M. Terzo, “A mixed approach for the control of a testing equipment employed for earthquake isolation systems,” Journal of Mechanical Engineering Science, vol. 228, no. 2, pp. 246-261, 2014.
[10] A. K. Chopra, Dynamics of Structures: Theory and Applications to Earthquake Engineering, 4th ed. Englewood Cliffs, NJ: Prentice Hall, 2012.