Effects of Damper Locations and Base Isolators on Seismic Response of a Building Frame
Authors: Azin Shakibabarough, Mojtaba Valinejadshoubi, Ashutosh Bagchi
Abstract:
Structural vibration means repetitive motion that causes fatigue and reduction of the performance of a structure. An earthquake may release high amount of energy that can have adverse effect on all components of a structure. Therefore, decreasing of vibration or maintaining performance of structures such as bridges, dams, roads and buildings is important for life safety and reducing economic loss. When earthquake or any vibration happens, investigation on parts of a structure which sustain the seismic loads is mandatory to provide a safe condition for the occupants. One of the solutions for reducing the earthquake vibration in a structure is using of vibration control devices such as dampers and base isolators. The objective of this study is to investigate the optimal positions of friction dampers and base isolators for better seismic response of 2D frame. For this purpose, a two bay and six story frame with different distribution formats was modeled and some of their responses to earthquake such as inter-story drift, max joint displacement, max axial force and max bending moment were determined and compared using non-linear dynamic analysis.
Keywords: Fast nonlinear analysis, friction damper, base isolator, seismic vibration control, seismic response.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1124682
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1668References:
[1] Constantinou, M. C. and Symans, M. D. (1993) “Seismic Response of Structures with Supplemental Damping”, Structural design of tall buildings, 2(2).
[2] Kobori. T, and Minai. R, (1955), “Nonlinear structural vibration subjected to the earthquake loading”, Part 1: Natural nonlinear response process, Trans. Architectural Institute of Japan 51, pp.61-69.
[3] Soong, T. T., (1990); “Active structural control: theory and practice”, 1st ed., Longman Scientific & Technical, UK and John Wiley and Sons, New York.
[4] Xu, K.; Igusa, T. (1992). Dynamic characteristic of multiple substructures with closely-spaced frequencies, Earthquake Engineering and Structural Dynamics 21: 1059– 1070.
[5] M. H. Milman and C. C. Chu, “Optimization methods for passive damper replacement and tuning,” Journal of Guidance, Control, and Dynamics, vol. 17, no. 4, pp. 848–856, 1994.
[6] Gioncu, V. (2000), Ìnfluence of strain-rate. In F. M Mazzolani, and R. Tremblay, “Behaviour of steel structures in seismic areas” proceedings of the third international conference STESSA 2000, Montreal. Rotterdam: Balkema.