Influence of Gravity on the Performance of Closed Loop Pulsating Heat Pipe

Authors: Vipul M. Patel, H. B. Mehta

Abstract:

Closed Loop Pulsating Heat Pipe (CLPHP) is a passive two-phase heat transfer device having potential to achieve high heat transfer rates over conventional cooling techniques. It is found in electronics cooling due to its outstanding characteristics such as excellent heat transfer performance, simple, reliable, cost effective, compact structure and no external mechanical power requirement etc. Comprehensive understanding of the thermo-hydrodynamic mechanism of CLPHP is still lacking due to its contradictory results available in the literature. The present paper discusses the experimental study on 9 turn CLPHP. Inner and outer diameters of the copper tube are 2 mm and 4 mm respectively. The lengths of the evaporator, adiabatic and condenser sections are 40 mm, 100 mm and 50 mm respectively. Water is used as working fluid. The Filling Ratio (FR) is kept as 50% throughout the investigations. The gravitational effect is studied by placing the evaporator heater at different orientations such as horizontal (90 degree), vertical top (180 degree) and bottom (0 degree) as well as inclined top (135 degree) and bottom (45 degree). Heat input is supplied in the range of 10-50 Watt. Heat transfer mechanism is natural convection in the condenser section. Vacuum pump is used to evacuate the system up to 10-5 bar. The results demonstrate the influence of input heat flux and gravity on the thermal performance of the CLPHP.

Keywords: Closed loop pulsating heat pipe, gravity, heat input, orientation.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1123963

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1422

References:

kachi. Patent No. 4,921,041. United States of America. May 1, 1990.
[2] V. I. Dmitrin, Y. F. Maidanik, and V. G. Pastukhov, “Development and investigation of compact cooler using a pulsating heat pipe”. vol. 48, no. 4, pp. 565–571, August, 2010.
[3] M. Arab, M. Soltanieh, and M. B. Shafii, “Experimental investigation of extra-long pulsating heat pipe application in solar water heaters”. Thermal Fluid Science, vol. 42, pp. 6–15. October, 2012.
[4] P. Supirattanakul, S. Rittidech, and B. Bubphachot, “Application of a closed-loop oscillating heat pipe with check valves (CLOHP/CV) on performance enhancement in air conditioning system”. Energy Build. vol. 43, no. 7, pp. 1531–1535, 2011.
[5] G. Burban, V. Ayel, A. Alexandre, P. Lagonotte, Y. Bertin, and C. Romestant, “Experimental investigation of a pulsating heat pipe for hybrid vehicle applications”. Applied Thermal Engineering, vol. 50, no. 1, pp. 94–103, 2013.
[6] J. Clement and X. Wang, “Experimental investigation of pulsating heat pipe performance with regard to fuel cell cooling application”. Applied Thermal Engineering, vol. 50, no. 1, pp. 268–274, 2013.
[7] S. Khandekar, “Pulsating heat pipe based heat exchangers”. Proc. 21st Int. Symp. Transp. Phenom., no. iii, pp. 2–5, 2010.
[8] S. Khandekar and A. Gupta, “Embedded Pulsating Heat Pipe Radiators”. 14th Int. Heat Pipe Conf. Florianopolis, Brazil, vol. 1, no. 1, pp. 258–263, 2007.
[9] Y. Zhang and A. Faghri, “Advances and Unsolved Issues in Pulsating Heat Pipes”. Heat Transf. Eng., vol. 29, no. 1, pp. 20–44, 2008.
[10] P. Charoensawan, S. Khandekar, M. Groll, and P. Terdtoon “Closed loop pulsating heat pipes - Part A: Parametric experimental investigations”. Appl. Therm. Eng., vol. 23, no. 16, pp. 2009–2020, 2003.
[11] S. Akter Jahan, M. Ali, and M. Quamrul Islam, “Effect of inclination angles on heat transfer characteristics of a Closed Loop Pulsating Heat Pipe (CLPHP)”. Procedia Engineering, vol. 56, pp. 82–87, 2013.
[12] R. Naik, V. Varadarajan, G. Pundarika, and K. R. Narasimha, “Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe”. vol. 6, no. 2, pp. 267–275, 2013.
[13] N. Saha, P. K. Das, and P. K. Sharma, “Influence of process variables on the hydrodynamics and performance of a single loop pulsating heat pipe”. Heat Mass Transfer, vol. 74, pp. 238–250, 2014.
[14] M. Vogel, “Thermal Characterization of Pulsating Heat Pipes.” Therm. Thermomechanical Proc. 10th Intersoc. Conf. Phenom. Electron. Syst., pp. 552–556, 2006.
[15] H. Gamit, V. More, B. Mukund, and H. B. Mehta, “Experimental investigations on pulsating heat pipe”. The 7th International Conference on Applied Energy, vol. 00, pp. 1–6, 2015.