Performance of Modified Wedge Anchorage System for Pre-Stressed FRP Bars
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Performance of Modified Wedge Anchorage System for Pre-Stressed FRP Bars

Authors: Othman S. Alsheraida, Sherif El-Gamal

Abstract:

Fiber Reinforced Polymer (FRP) is a composite material with exceptional properties that are capable to replace conventional steel reinforcement in reinforced and pre-stressed concrete structures. However, the main obstacle for their wide use in pre-stressed concrete application is the anchorage system. Due to the weakness of FRP in the transverse direction, the pre-stressing capacity of FRP bars are limited. This paper investigates the modification of the conventional wedge anchorage system to be used for stressing of FRP bars in pre-stressed applications. Epoxy adhesive material with glass FRP (GFRP) bars and conventional steel wedge were used in this paper. The GFRP bars are encased with epoxy at the anchor zone and the wedge system was used in pull-out test. The results showed a loading capacity of 47.6 kN which is 69% of the bar ultimate capacity. Additionally, nylon wedge was made with the same dimensions of the steel wedge and tested for GFRP bars without epoxy layer. The nylon wedge showed a loading capacity of 19.7 kN which is only 28.5% of the ultimate bar capacity.

Keywords: Anchorage, concrete, epoxy, FRP, pre-stressed.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1108791

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2520

References:


[1] El-Gamal S.E., Al-Nuaimi A., Al-Saidy A., Al-Lawati A. Flexural Strengthening of RC Beams Using Near Surface Mounted Fibre Reinforced Polymers. Proceedings of the Brunei International Conference on Engineering and Technology, Institut Teknologi Brunei, Brunei Darussalam, November 1-3, 2014.
[2] Benmokrane, B., El-Salakawy, E., El-Gamal, S.E., and Sylvain, G. (2007) Construction and Testing of an Innovative Concrete Bridge Deck Totally Reinforced with Glass FRP Bars: Val-Alain Bridge on Highway 20 East. ASCE, Journal of Bridge Engineering, Vol. 12, No. 5, September, pp. 632-645.
[3] Benmokrane, B., El-Salakawy, E., El-Ragaby, A., El-Gamal, S.E. (2007) Performance Evaluation of Innovative Concrete Bridge Deck Slabs Reinforced with Fibre-Reinforced Polymer Bars. Canadian Journal of Civil Engineering, Vol. 34, No 3, pp. 298-310. El-Gamal, S.E., Benmokrane, B., and El-Salakawy, E.F., (2009) Cracking and Deflection Behavior of One-Way Parking Garage Slabs Reinforced with CFRP Bars. ACI Special Publication, SP-264-3, pp. 33-52.
[4] El-Ragaby, A., El-Gamal, S.E., El-Salakawy, E.F., and Benmokrane, B. (2006) Performance of Concrete Bridge Deck Slabs Reinforced with Glass FRP Composite Reinforcing Bars. Proceedings of the 3th International Conference on Bridge Maintenance, Safety, and Management, (IABMAS), Porto, Portugal, Jul. 9 p.
[5] El-Gamal, S.E., Benmokrane, B., El-Salakawy, E., Cousin, P., Wiseman, A., (2009) Durability and Structural Performance of CFRP-RC Parking Garage’s Slabs after Being in Service for Eight Years. Canadian Journal of Civil Eng., 36, 4, 617-627.
[6] Benmokrane. B., Eisa. M., El-Gamel. S.E., Denis Thébeau, and El- Salakawy. E. (2008) Pavement System Suiting Local Conditions. ACI Concrete International Magazine, November, pp. 34-39.
[7] Eisa, M., El-Gamal S.E., El-Salakawy, E. and Benmokrane, B. (2008) Design and Construction of First GFRP-CRCP Slabs Implemented on Highway 40 East (Montreal). Proceedings of the 37th Annual Conference of the Canadian Society for Civil Engineering, Québec City, Québec, Canada, June 10-13.
[8] Schmidt, J. W., Bennitz, A., Täljsten, B., Goltermann, P., & Pedersen, H. (2012). Mechanical anchorage of FRP tendons–A literature review. Construction and Building Materials, 32, 110-121.
[9] Al-Mayah, A., Soudki, K., & Plumtree, A. (2001). Mechanical behavior of CFRP rod anchors under tensile loading. Journal of Composites for Construction, 5(2), 128-135.
[10] Elrefai, A., West, J. S., & Soudki, K. (2007). Performance of CFRP tendon–anchor assembly under fatigue loading. Composite structures, 80(3), 352-360.
[11] J.W. Schmidt, B. Täljsten, A. Bennitz, and H. Pedersen, “FRP tendon anchorage in post-tensioned concrete structures,” In Proc. International Conference on concrete repair, Rehabilitation and Retrofitting (2), pp. 419-420, 2009.
[12] ACI Committee 440, “Prestressing Concrete Structures with FRP Tendons (ACI 440.4R-04),” American Concrete Institute, pp. 11-13, 2004.
[13] ISIS Educational Module 9, “Prestressing Concrete Structures with Fiber Reinforced Polymers,” ISIS Canada, pp. 7-8, 2007.
[14] A. Al-Mayah, K. A. Soudki, and A. Plumtree, “Experimental and analytical investigation of a stainless steel anchorage for CFRP prestressing tendons”. PCI journal, 46(2), pp. 88-92, 2001.
[15] X. Wang, P. Xu, Z. Wu, and J. Shi, “A novel anchor method for multitendon FRP cable: Concept and FE study,” Composite Structures, 120, pp. 552-564, 2015.
[16] A. Nanni, C.E. Bakis, E.F. O'Neil, and T.O. Dixon, “Short-term sustained loading of FRP tendon anchor systems,” Construction and Building Materials, 10(4), pp. 255-266, 1996.
[17] R. Fico, N. Galati, A. Prota, and A. Nanni, “Design and construction of a bridge deck using mild and post-tensioned FRP bars,” ACI Special Publication, 230, 2005.
[18] E.Y. Sayed-Ahmed, and N.G. Shrive, “A new steel anchorage system for post-tensioning applications using carbon fibre reinforced plastic tendons,” Canadian Journal of Civil Engineering, 25(1), pp. 113-127, 1998.
[19] J.W. Schmidt, A. Bennitz, P. Goltermann, and D. Lund Ravn, “External post-tensioning of CFRP tendons using integrated sleeve-wedge anchorage,” In Proc. 6th International Conference on FRP Composites in Civil Engineering, 2012, pp. 1-8.
[20] T. I. Campbell, N. G. Shrive, K. A. Soudki, A. Al-Mayah, J.P. Keatley, and M. M. Reda, “Design and evaluation of a wedge-type anchor for fibre reinforced polymer tendons,” Canadian Journal of Civil Engineering, 27(5), pp. 985-992, 2000.
[21] ACI Committee 440, “Prestressing Concrete Structures with FRP Tendons (ACI 440.4R-06),” American Concrete Institute, pp. 11-13, 2004.