Photoplethysmography-Based Device Designing for Cardiovascular System Diagnostics
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Photoplethysmography-Based Device Designing for Cardiovascular System Diagnostics

Authors: S. Botman, D. Borchevkin, V. Petrov, E. Bogdanov, M. Patrushev, N. Shusharina

Abstract:

In this paper, we report the development of the device for diagnostics of cardiovascular system state and associated automated workstation for large-scale medical measurement data collection and analysis. It was shown that optimal design for the monitoring device is wristband as it represents engineering trade-off between accuracy and usability. Monitoring device is based on the infrared reflective photoplethysmographic sensor, which allows collecting multiple physiological parameters, such as heart rate and pulsing wave characteristics. Developed device uses BLE interface for medical and supplementary data transmission to the coupled mobile phone, which processes it and send it to the doctor's automated workstation. Results of this experimental model approbation confirmed the applicability of the proposed approach.

Keywords: Cardiovascular diseases, health monitoring systems, photoplethysmography, pulse wave, remote diagnostics.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1108416

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3149

References:


[1] Lee, Drew E., and Richard S. Cooper. "Recommendations for Global Hypertension Monitoring and Prevention." Current Hypertension Reports 11, no. 6, 2009, 444-449.
[2] Chang, F. C., C. K. Chang, C. C. Chiu, S. F. Hsu, and Y. D. Lin. "Variations of HRV Analysis in Different Approaches." In Computers in Cardiology, 2007, pp. 17-20. IEEE, 2007.
[3] Allen, John. "Photoplethysmography and Its Application in Clinical Physiological Measurement." Physiological measurement 28, no. 3, 2007, R1.
[4] Nam, Dong-Hyun, Woo-Beom Lee, You-Sik Hong, and Sang-Suk Lee. "Measurement of Spatial Pulse Wave Velocity by Using a Clip-Type Pulsimeter Equipped with a Hall Sensor and Photoplethysmography." Sensors 13, no. 4, 2013, 4714-4723.
[5] Lee, Sang-Suk, Myoung-Chone An, and Sung-Hoon Ahn. "A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices." Journal of Magnetics 14, no. 3, 2009, 132-136.
[6] Cui, Weijia, Lee E. Ostrander, and Bok Y. Lee. "In vivo Reflectance of Blood and Tissue as a Function of Light Wavelength." Biomedical Engineering, IEEE Transactions on 37, no. 6, 1990, 632-639.
[7] Zijlstra, W. G., A. Buursma, and W. P. Meeuwsen-Van der Roest. "Absorption Spectra of Human Fetal and Adult Oxyhemoglobin, De- Oxyhemoglobin, Carboxyhemoglobin, and Methemoglobin." Clinical chemistry 37, no. 9, 1991, 1633-1638.
[8] Maeda, Yuka, Masaki Sekine, and Toshiyo Tamura. "The Advantages of Wearable Green Reflected Photoplethysmography." Journal of medical systems 35, no. 5, 2011, 829-834.
[9] Giltvedt, J., A. Sira, and P. Helme. "Pulsed Multifrequency Photoplethysmograph." Medical and Biological Engineering and Computing 22, no. 3, 1984, 212-215.
[10] Challoner, A. V. J. "Photoelectric Plethysmography for Estimating Cutaneous Blood Flow." Non-Invasive Physiological Measurements 1, 1979, 125-151.
[11] Korpas, D., J. Halek, and L. Dolezal. "Parameters Describing the Pulse Wave." Physiological research 58, no. 4, 2009, 473.