Analysis of the Performance of a Solar Water Heating System with Flat Collector
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Analysis of the Performance of a Solar Water Heating System with Flat Collector

Authors: Aurea LĂșcia Georgi Vendramin, Carlos Itsuo Yamamoto, Carlos Eduardo Camargo Nogueira, Anderson Miguel Lenz, Samuel N. Souza Melegari

Abstract:

The thermal performance of a solar water heating with 1.00 m2 flat plate collectors in Cascavel - PR, is which presented in this article, paper presents the solution to leverage the marketing of solar heating systems through detailed constituent materials of the solar collector studies, these abundant materials in construction, such as expanded polyethylene, PVC, aluminum and glass tubes, mixing them with new materials to minimize loss of efficiency while decreasing its cost. The system was tested during months and the collector obtained maximum recorded temperature of outlet fluid of 55°C, while the maximum temperature of the water at the bottom of the hot water tank was 35°C. The average daily energy collected was 19.6 MJ/d; the energy supplied by the solar plate was 16.2 MJ/d; the loss in the feed pipe was 3.2 MJ/d; the solar fraction was 32.2%, the efficiency of the collector was 45.6% and the efficiency of the system was 37.8%.

Keywords: Recycled materials, energy efficiency, solar collector.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1100773

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3022

References:


[1] European Standards, CSN EN 12975-2 e Thermal Solar Systems and Components and Solar Collectors, Part 1: General Requirements (2006).
[2] ASHRAE-93, Methods of Testing to Determine the Thermal Performance of Solar Collectors, ASHRAE, Atlanta, 2003.
[3] E. Zambolin, D. Del Col, Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions, Solar Energy 84 (8) (2010) from 1382 to 1396.
[4] R. C. Tiwari, A. Kumar, S. K. Gupta, G. D. Sootha, Thermal performance of flat-plate solar collectors manufactured in India, Energy Conversion and Management 31 (4) (1991) from 309 to 313.
[5] E. H. Amer, J. K. Nayak, G. K. Sharma, Transient method for testing flat- late solar collectors, Energy Conversion and Management 39 (7) (1998) from 549 to 558.
[6] Z. Chen, S. Furbo, B. Perers, J. Fan, E. Andersen, Efficiencies of flat plate solar collectors at different flow rates, Energy Procedia 30 (0) (2012) from 65 to 72.
[7] I. M. Michaelides, P. C. Eleftheriou, An experimental investigation of the performance boundaries of a solar water heating system, Experimental Thermal and Fluid Science 35 (6) (2011) from 1002 to 1009.
[8] L. M. Ayompe, A. Duffy, M. Mc Keever, M. Conlon, S. J. McCormack, Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate, Energy 36 (5) (2011) from 3370 to 3378.
[9] Building Research Establishment, Clear Line Solar Thermal Test Report and Average Household Simulation. Client Report Number 251175, Viridian Solar, 2009. Available at: http://www.viridiansolar.co.uk/Assets/Files/ BRE_Report_Viridian_Solar_Average_House_Simulation.pdf.