Determination of Resistance to Freezing of Bonded Façade Joint
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32797
Determination of Resistance to Freezing of Bonded Façade Joint

Authors: B. Nečasová, P. Liška, J. Šlanhof

Abstract:

Verification of vented wooden façade system with bonded joints is presented in this paper. The potential of bonded joints is studied and described in more detail. The paper presents the results of an experimental and theoretical research about the effects of freeze cycling on the bonded joint. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure. Planks from wooden plastic composite and Siberian larch are representing facade cladding. Two types of industrial polyurethane adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent curing and conditioning of test samples. All test samples were subjected to 15 cycles that represents sudden temperature changes, i.e. immersion in a water bath at (293.15 ± 3) K for 6 hours and subsequent freezing to (253.15 ± 2) K for 18 hours. Furthermore, the retention of bond strength between substructure and cladding wastested and strength in shear was determined under tensile stress.Research data indicate that little, if any, damage to the bond results from freezingcycles. Additionally, the suitability of selected group of adhesives in combination with timber substructure was confirmed.

Keywords: Adhesive system, bonded joints, wooden lightweight façade, timber substructure.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1100655

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4638

References:


[1] J. Šlanhof et al., “Sealing Possibilities for Wood Elements”, In proceedings of People, Building and Environment 2014, ISSN 1805-6784.´, Ed. Brno Technical University, Brno, 2014, pp. 1-2.
[2] J. Kuczmaszewski, “Fundamentals of metal-metal adhesive joint design”, Ed. Lublin University of Technolgy, Polish Academy of Sciences, Lublin Branch, Lublin 2006, ISBN 83-89293-11-0, pp.8-9.
[3] IJ.J. van Straalen et al. "Structural Adhesive Bonded Joints in Engineering – drafting design rules", International Journal of Adhesion and Adhesives. Elsevier, vol. 18, pp 41- 49, February 1998.
[4] H. Pasternak., Y. Ciupack. “Development of Eurocode-based design rules for adhesive bonded joints”. International Journal of Adhesion and Adhesives. Elsevier, vol. 53, pp 97 – 106, September 2014.
[5] P. Liška, J. Šlanhof, B. Nečasová, “Revitalization of Facade Cladding with the Use of Bonded Joints”, Advanced Materials Research Vol. 1041, ISSN 1662-8985, Trans Tech Publications, Zurich-Durnten, 2014. pp 195-198.
[6] B. Nečasová, P. Liška, J. Šlanhof, “Wooden Facade and Determination of Strength of Bonded Timber Joints”, In proceedings of ARSA – Advanced Research in Scientific Areas, ISSN 1338-9831, EDIS – Publishing Institution of the University of Zilina, Žilina, 2014, pp. 1-2.
[7] ČSN 73 2577. Test for surface finish adhesion of building structures to the base. Prague: Czech Standards Institute, 1981.
[8] ČSN EN 1465. Adhesives – Determination of tensile lap-shear strength of bonded assemblies. Prague: Czech Standards Institute, 2009.J.
[9] ČSN 73 2579. Test for frost resistance of surface finish of building structures. Prague: Czech Standards Institute, 1981.
[10] Sika, s.r.o., “SikaTack – Panel system: The panel fixing system for ventilated facades”, In system product data sheet, Ed. 26/07/2012, ID 01-05-02-01-002-0.
[11] Dinol GmbH, “Dinitrol F500 LP: Technical data sheet”, In technical data sheet. 2014.