Behavior of Confined Columns under Different Techniques
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33122
Behavior of Confined Columns under Different Techniques

Authors: Mostafa Osman, Ata El-Kareim Shoeib Soliman

Abstract:

Since columns are the most important elements of the structures, failure of one column in a critical location can cause a progressive collapse. In this respect, the repair and strengthening of columns is a very important subject to reduce the building failure and to keep the columns capacity. Twenty columns with different parameters is tested and analysis. Eleven typical confined reinforced concrete (RC) columns with different types of techniques are assessment. And also, four confined concrete columns with plastic tube (PVC) are tested with and with four paralleling tested of unconfined plain concrete. The techniques of confined RC columns are mortar strengthening, Steel rings strengthening, FRP strengthening. Moreover, the technique of confined plain concrete (PC) column is used PVC tubes. The columns are tested under uniaxial compressive loads studied the effect of confinement on the structural behavior of circular RC columns. Test results for each column are presented in the form of crack patterns, stress-strain curves. Test results show that confining of the RC columns using different techniques of strengthening results significant improvement of the general behavior of the columns and can used in construction. And also, tested confined PC columns with PVC tubes results shown that the confined PC with PVC tubes can be used in economical building. The theoretical model for predicted column capacity is founded with experimental factor depends on the confined techniques used and the strain reduction.

Keywords: Confined reinforced concrete column, CFRP, GFRP, Mortar.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1099456

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2642

References:


[1] Technical report on the design and use of externally bonded fiber reinforced polymer reinforcement (FRP EBR) for reinforced concrete structures prepared by a working party of the Task Group 9.3 FRP (Fiber Reinforced Polymer) reinforcement for concrete structures, 2001, P.139
[2] Abul-Seoud, O.M: Behavior Of partial strengthened reinforced concrete columns under axial loads,” M.Sc Thesis, Faculty of Engineering, Cairo University, 1999, p.150.
[3] Priestley, M.J.N.; Seible, K; Xiao, Y. and Verma, R. “A Steel jacket retrofitting of reinforced concrete bridge columns for enhanced shear strength. Part (1): Theoretical considerations and test design,” ACI Structural Journal, vol. 91, no. 5, Sept.-Oct., 1994, P.394-405.
[4] Ata El-kareim Shoeib ''Behavior of long confined concrete column,” Sci. Bull. Fac. Eng. Ain Shams Univ. Egypt, Elsevier, vol.2., Issues 3–4, 2011, pp.141–148
[5] Silvia Rocca1 and et al “Review of design guidelines for FRP confinement of reinforced concrete columns of noncircular cross sections,” Journal of composites for construction. Jan/Feb., 2008, P.80– 92.
[6] American Concrete Institute ACI. “Guide for the design and construction of externally bonded FRP systems for strengthening of concrete structures,” ACI 440.2R-02, Farmington Hills, Mich, 2002.pp.42
[7] Canadian Standards Association CSA. “Design and construction of building components with fiber-reinforced polymers,” CSA-S806, Rexdale, Ont., Canada, 2002.
[8] Richart, F.E., Bradtzaeg, A. and Brown, R. L. “A study of the failure of concrete under combined compressive stresses,” Bulletin No. 185, Engineering experimental station University of Illinois, Urbana, 1928 pp. 104
[9] Saatcioglu, M., and Razvi, S. R., “High-Strength Concrete Columns with Square Sections under Concentric Compression,” Journal of Structural Engineering , ASCE, Vol. 124, no. 12 (1998) pp. 1438-1447
[10] Lam, L. and Teng, J.G. “Design-oriented stress-strain model for FRPconfined concrete”, Construction and Building Materials, 17(6-7): (2003a). pp. 471-489
[11] Spoelstra, M.R., and Monti, G. “FRP-confined concrete model”, Journal of composites for Construction, ASCE, 3(3), (1999) pp.143-150.
[12] Ata El-kareim Shoeib, “Efficiency of used glass fiber reinforced polymer for strengthening concrete and reinforced concrete elements of constructions,” Ph.D. thesis, Belgorod State Technological University, Belgorod, Russia, 2005, p.159.
[13] Bazant Z.P. and B.H. Oh, “Rock fracture via strain softening finite elements,” J. Eng. Mech. Ascvol. 110, 1985, pp.1015 – 1035.
[14] Bažant, Z. P., and Xiang, Y., “Size Effect in Compression Fracture: Splitting Crack Band Propagation,” J. Eng. Mech.,123, (1997) pp. 162– 172
[15] Menetrey, P. and Willam, K.J. “Triaxial failure criterion for concrete and its generalization,” ACI Structural Journal, vol.93, no.3, 1995, pp.311-318.
[16] Bazant Z.P. and B.H. Oh, “Crack band theory of fracture of concrete,” Mater struct (RILEM paris), 1983, pp.155 – 177.
[17] Cole, C. and Belarbi, A., “Confinement Characteristics of Rectangular FRP-Jacketed RC Columns” Proceedings of the Fifth International Symposium on Fiber Reinforced Polymer for Reinforced Concrete Structures (FRPRCS-5), Cambridge, UK, 2001, pp. 823-832.
[18] Ata El-kareim Shoeib, “Failure mechanism for confined plain concrete column” International Journal of Civil, Structural, Environmental and Infrastructure Engineering Research and Development,” IJCSEIERD India,vol.3, no. 5, 2013, pp.249-268.
[19] ECP 208,“Egyptian Code of Practice for the use of Fiber Reinforced Polymer (FRP) in the construction fields,” 2005, Part 4, p.69.