Visualized Flow Patterns around and inside a Two-Sided Wind-Catcher in the Presence of Upstream Structures
Authors: M. Afshin, A. Sohankar, M. Dehghan Manshadi, M. R. Daneshgar, G. R. Dehghan Kamaragi
Abstract:
In this paper, the influence of upstream structures on the flow patternaround and inside the wind-catcher is experimentally investigated by smoke flow visualization techniques. Wind-catchers are an important part of natural ventilation in residential buildings or public places such as shopping centers, libraries, etc. Wind-catchers might be also used in places of high urban densities; hence their potential to provide natural ventilation is dependent on the presence of upstream structures. In this study, the two-sided wind-catcher model was based on a real wind-catcher observed in the city of Yazd, Iran. The present study focuses on the flow patterns around and inside the isolated two-sided wind-catcher, and on a two-sided wind-catcher in the presence of an upstream structure. The results show that the presence of an upstream structure influences the airflow pattern force and direction. Placing a high upstream structure reverses the airflow direction inside the wind-catcher.
Keywords: Natural Ventilation, Smoke Flow Visualization, Two-Sided Wind-Catcher.
Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1097453
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1993References:
[1] N.Khamoushian, “Modern Wind-catcher”, Memari, pp. 113, 2011.
[2] V.Kalantar, “Numerical simulation of cooling performance of wind tower (Baud-Geer) In hot and arid region”, Renewable Energy, vol. 34, pp. 246-254, 2009.
[3] M.N. Bahadori, M. Mazidi, A.R. Dehghani, “Experimental investigation of new design of wind towers”, Renewable Energy, vol. 33 pp. 2273-2281, 2008.
[4] C. Karakatsanis, M. N.Bahadori, B.J. Vickery, “Evaluation of pressure coefficient and estimation of air flow rates in buildings employing wind towers”, Solar Energy, vol. 37, pp. 363-374, 1986.
[5] Y. Su, S.B. Riffat, Y.-L. Lin, N. Khan, “Experimental and CFD study of ventilation flow rate of a Mono-draught wind catcher”, Energy and Buildings, vol. 40, pp. 1110-1116, 2008.
[6] A.A. Elmualim, H.B. Awbi, “Wind tunel and CFD investigation of the performance of wind catcher ventilation system”, International Journal of ventilation, vol. 1, pp.53-64, 2002.
[7] H. Montazeri, F.Montazeri, R. Azizian, S. Mostafavi, “Two-sided wind catcher performance evaluation using experimental, numerical and analytical modeling”, Renewable Energy, vol. 35, pp. 1424-1435, 2010.
[8] H. Montazeri, R. Azizian, “Experimental study on natural ventilation performance of one-sided wind catcher”, Building and Environment, vol. 43,pp. 2193-2202, 2008.
[9] H. Montazeri, “Experimental and numerical study on natural ventilation performance of various multi-opening wind catcher”, Building and Environment, vol. 46, pp. 370-378, 2011.
[10] M.K. Esfeh, A.A. Dehghan, M.D. Manshadi, S. Mohagheghian, “Visualized flow structure around and inside of one-sided wind-catchers”, Energy and Buildings, vol. 55, pp. 545-552, 2012.
[11] A.A. Dehghan, M.K. Esfeh, M.D. Manshadi, “Natural ventilation characteristics of one-sided wind catchers:experimental and analytical evaluation”, Energy and Buildings, vol. 61, pp. 366-377, 2013.
[12] DehghanKamaragi G.R, (2014). “The ventilation and cooling in the traditional architecture of the Persian Gulf: History devices, modeling, performance evaluation”. Thesis, University of Paris-Est, France, 2014.