Search results for: S. Sharaf
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5

Search results for: S. Sharaf

5 Nullity of t-Tupple Graphs

Authors: Khidir R. Sharaf, Didar A. Ali

Abstract:

The nullity η(G) of a graph is the occurrence of zero as an eigenvalue in its spectra. A zero-sum weighting of a graph G is real valued function, say f from vertices of G to the set of real numbers, provided that for each vertex of G the summation of the weights f(w) over all neighborhood w of v is zero for each v in G.A high zero-sum weighting of G is one that uses maximum number of non-zero independent variables. If G is graph with an end vertex, and if H is an induced subgraph of G obtained by deleting this vertex together with the vertex adjacent to it, then, η(G)= η(H). In this paper, a high zero-sum weighting technique and the endvertex procedure are applied to evaluate the nullity of t-tupple and generalized t-tupple graphs are derived  and determined for some special types of graphs,

 Also, we introduce and prove some important results about the t-tupple coalescence, Cartesian and Kronecker products of nut graphs.

Keywords: Graph theory, Graph spectra, Nullity of graphs.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1915
4 Experimental Investigation of Phase Distributions of Two-phase Air-silicone Oil Flow in a Vertical Pipe

Authors: M. Abdulkadir, V. Hernandez-Perez, S. Sharaf, I. S. Lowndes, B. J. Azzopardi

Abstract:

This paper reports the results of an experimental study conducted to characterise the gas-liquid multiphase flows experienced within a vertical riser transporting a range of gas-liquid flow rates. The scale experiments were performed using an air/silicone oil mixture within a 6 m long riser. The superficial air velocities studied ranged from 0.047 to 2.836 m/ s, whilst maintaining a liquid superficial velocity at 0.047 m/ s. Measurements of the mean cross-sectional and time average radial void fraction were obtained using a wire mesh sensor (WMS). The data were recorded at an acquisition frequency of 1000 Hz over an interval of 60 seconds. For the range of flow conditions studied, the average void fraction was observed to vary between 0.1 and 0.9. An analysis of the data collected concluded that the observed void fraction was strongly affected by the superficial gas velocity, whereby the higher the superficial gas velocity, the higher was the observed average void fraction. The average void fraction distributions observed were in good agreement with the results obtained by other researchers. When the air-silicone oil flows were fully developed reasonably symmetric profiles were observed, with the shape of the symmetry profile being strongly dependent on the superficial gas velocity.

Keywords: WMS, phase distribution, silicone-oil, riser

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2272
3 FACTS Based Stabilization for Smart Grid Applications

Authors: Adel M. Sharaf, Foad H. Gandoman

Abstract:

Nowadays, Photovoltaic-PV Farms/ Parks and large PV-Smart Grid Interface Schemes are emerging and commonly utilized in Renewable Energy distributed generation. However, PVhybrid- Dc-Ac Schemes using interface power electronic converters usually has negative impact on power quality and stabilization of modern electrical network under load excursions and network fault conditions in smart grid. Consequently, robust FACTS based interface schemes are required to ensure efficient energy utilization and stabilization of bus voltages as well as limiting switching/fault onrush current condition. FACTS devices are also used in smart grid- Battery Interface and Storage Schemes with PV-Battery Storage hybrid systems as an elegant alternative to renewable energy utilization with backup battery storage for electric utility energy and demand side management to provide needed energy and power capacity under heavy load conditions. The paper presents a robust interface PV-Li-Ion Battery Storage Interface Scheme for Distribution/Utilization Low Voltage Interface using FACTS stabilization enhancement and dynamic maximum PV power tracking controllers. Digital simulation and validation of the proposed scheme is done using MATLAB/Simulink software environment for Low Voltage- Distribution/Utilization system feeding a hybrid Linear-Motorized inrush and nonlinear type loads from a DC-AC Interface VSC-6- pulse Inverter Fed from the PV Park/Farm with a back-up Li-Ion Storage Battery.

Keywords: AC FACTS, Smart grid, Stabilization, PV-Battery Storage, Switched Filter-Compensation (SFC).

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3247
2 Use of Hair as an Indicator of Environmental Lead Pollution: Changes after Twenty Years of Phasing Out Leaded Gasoline

Authors: M. A. Abou Donia, A. A. K. Abou-Arab, Nevin E. Sharaf, A. K. Enab, Sherif R. Mohamed

Abstract:

Lead (Pb) poisoning is one of the most common and preventable environmental health problems. There are different sources of environmental pollution with lead as lead alkyl additives in petrol and manufacturing processes. Pb in the atmosphere can be deposited in urban soils, and may then be re-suspended to re-enter the atmosphere. This could increase human exposure to Pb and cause long-term health effects. Thus, monitoring Pb pollution is considered one of the major tasks in controlling pollution. Scalp hair can be utilized for the determination of lead (Pb) concentration. It provides a lasting record of metal intakes of weeks or even months, and for most metals, their accumulation in hair reflects their accumulation in the whole body. This work was conducted to investigate the concentration of lead in male scalp hair of Cairo (residential-traffic and residential-industrial) and rural residents after twenty years of phasing out of leaded gasoline. Results indicated that the mean concentration of lead in hair of residential-traffic (9.7552 μg/g ±0.71) and residential-industrial (12.3288 μg/g ±1.13) was significantly higher than that in rural residents (4.7327 μg/g ±0.67). The mean concentration of lead in hair of resident’s industrial areas was the highest among Cairo residents and not the traffic areas as it was before phasing out of leaded gasoline. Twenty years of phasing out of leaded gasoline in Cairo has greatly improved the lead pollution among residents of traffic areas, but industrial areas residents were still suffering from lead pollution, which needs more efforts to control the sources of lead pollution.

Keywords: Heavy metals, lead, hair, biological sample, urban pollution, rural pollution.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1763
1 Use of Hair as an Indicator of Environmental Lead Pollution: Characteristics and Seasonal Variation of Lead Pollution in Egypt

Authors: A. A. K. Abou-Arab, M. A. Abou Donia, Nevin E. Sharaf, Sherif R. Mohamed, A. K. Enab

Abstract:

Lead being a toxic heavy metal that mankind is exposed to the highest levels of this metal from environmental pollutants. A total of 180 Male scalp hair samples were collected from different environments in Greater Cairo (GC), i.e. industrial, heavy traffic and rural areas (60 samples from each) having different activities during the period of, 1/5/2010 to 1/11/2012. Hair samples were collected during five stages. Data proved that the concentration of lead in male industrial areas of Cairo ranged between 6.2847 to 19.0432 μg/g, with mean value of 12.3288 μg/g. On the other hand, lead content of hair samples of residential-traffic areas ranged between 2.8634 to 16.3311 μg/g with mean value of 9.7552 μg/g. While lead concentration on the hair of the male residents living in rural area ranged between 1.0499-9.0402μg/g with mean value of 4.7327 μg/g. The Pb concentration in scalp hair of Cairo residents of residential-traffic and rural traffic areas was observed to follow the same pattern. The pattern was that of decrease concentration of summer and its increase in winter. Then, there was a marked increase in Pb concentration of summer 2012, and this increase was significant. These were obviously seen for the residential-traffic and rural areas residents. Pb pollution in residents of industrial areas showed the same seasonal pattern, but there was marked to decrease in Pb concentration of summer 2012, and this decrease was significant. Lead pollution in residents of GC was serious. It is worth noting that the atmosphere is still contaminated by lead despite a decade of using unleaded gasoline. Strong seasonal variation in higher Pb concentration on winter than in summer was found. Major contributions to the pollution with Pb could include industry emissions, motor vehicle emissions and long transported dust from outside Cairo. More attention should be paid to the reduction of Pb content of the urban aerosol and to the Pb pollution health.

Keywords: Hair, lead, environmental exposure, seasonal variations, Egypt.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1691