Search results for: Kazuhiko Ninomiya
4 Development of Nondestructive Imaging Analysis Method Using Muonic X-Ray with a Double-Sided Silicon Strip Detector
Authors: I-Huan Chiu, Kazuhiko Ninomiya, Shin’ichiro Takeda, Meito Kajino, Miho Katsuragawa, Shunsaku Nagasawa, Atsushi Shinohara, Tadayuki Takahashi, Ryota Tomaru, Shin Watanabe, Goro Yabu
Abstract:
In recent years, a nondestructive elemental analysis method based on muonic X-ray measurements has been developed and applied for various samples. Muonic X-rays are emitted after the formation of a muonic atom, which occurs when a negatively charged muon is captured in a muon atomic orbit around the nucleus. Because muonic X-rays have a higher energy than electronic X-rays due to the muon mass, they can be measured without being absorbed by a material. Thus, estimating the two-dimensional (2D) elemental distribution of a sample became possible using an X-ray imaging detector. In this work, we report a non-destructive imaging experiment using muonic X-rays at Japan Proton Accelerator Research Complex. The irradiated target consisted of a polypropylene material, and a double-sided silicon strip detector, which was developed as an imaging detector for astronomical obervation, was employed. A peak corresponding to muonic X-rays from the carbon atoms in the target was clearly observed in the energy spectrum at an energy of 14 keV, and 2D visualizations were successfully reconstructed to reveal the projection image from the target. This result demonstrates the potential of the nondestructive elemental imaging method that is based on muonic X-ray measurement. To obtain a higher position resolution for imaging a smaller target, a new detector system will be developed to improve the statistical analysis in further research.
Keywords: DSSD, muon, muonic X-ray, imaging, non-destructive analysis
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 12583 Comparative Study of Virtual Sickness between a Single-screen and Three-screen from Parallax Affect
Authors: Chompoonuch Jinjakam, Yuta Odagiri, Kobchai Dejhan, Hamamoto Kazuhiko
Abstract:
Virtual environment induces simulator sickness effect for some users. The purpose of this research is to compare the simulation sickness relative with parallax affect in one-screen and three-screen HoloStageTM system, measured by Simulation Sickness Questionnaire (SSQ). The results show the subjects tested in three-screen has less sickness than one-screen and effect from the Oculomotor (O) more than from the Disorientation (D) and more than from the Nausea (N) or represented in O>D>N.Keywords: Virtual environment, virtual sickness, simulationsickness questionnaire, HoloStageTM.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 16612 Ultrasonic Echo Image Adaptive Watermarking Using the Just-Noticeable Difference Estimation
Authors: Amnach Khawne, Kazuhiko Hamamoto, Orachat Chitsobhuk
Abstract:
Most of the image watermarking methods, using the properties of the human visual system (HVS), have been proposed in literature. The component of the visual threshold is usually related to either the spatial contrast sensitivity function (CSF) or the visual masking. Especially on the contrast masking, most methods have not mention to the effect near to the edge region. Since the HVS is sensitive what happens on the edge area. This paper proposes ultrasound image watermarking using the visual threshold corresponding to the HVS in which the coefficients in a DCT-block have been classified based on the texture, edge, and plain area. This classification method enables not only useful for imperceptibility when the watermark is insert into an image but also achievable a robustness of watermark detection. A comparison of the proposed method with other methods has been carried out which shown that the proposed method robusts to blockwise memoryless manipulations, and also robust against noise addition.
Keywords: Medical image watermarking, Human Visual System, Image Adaptive Watermark
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 16011 Identification and Analysis of Binding Site Residues in Protein-Protein Complexes
Authors: M. Michael Gromiha, Kiyonobu Yokota, Kazuhiko Fukui
Abstract:
We have developed an energy based approach for identifying the binding sites and important residues for binding in protein-protein complexes. We found that the residues and residuepairs with charged and aromatic side chains are important for binding. These residues influence to form cation-¤Ç, electrostatic and aromatic interactions. Our observation has been verified with the experimental binding specificity of protein-protein complexes and found good agreement with experiments. The analysis on surrounding hydrophobicity reveals that the binding residues are less hydrophobic than non-binding sites, which suggests that the hydrophobic core are important for folding and stability whereas the surface seeking residues play a critical role in binding. Further, the propensity of residues in the binding sites of receptors and ligands, number of medium and long-range contacts, and influence of neighboring residues will be discussed.
Keywords: Protein-protein interactions, energy based approach;binding sites, propensity, long-range contacts, hydrophobicity
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1397