Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1
Search results for: K.Volceka
1 The Method of Evaluation Artery Diameter from Ultrasound Video
Authors: U. Rubins, Z. Marcinkevics, K.Volceka
Abstract:
The cardiovascular system has become the most important subject of clinical research, particularly measurement of arterial blood flow. Therefore correct determination of arterial diameter is crucial. We propose a novel, semi-automatic method for artery lumen detection. The method is based on Gaussian probability function. Usability of our proposed method was assessed by analyzing ultrasound B-mode CFA video sequences acquired from eleven healthy volunteers. The correlation coefficient between the manual and semi-automatic measurement of arterial diameter was 0.996. Our proposed method for detecting artery boundary is novel and accurate enough for the measurement of artery diameter.Keywords: Ultrasound, boundary detection, artery diameter, curve fitting.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1592