Search results for: Asadullah Madni
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4

Search results for: Asadullah Madni

4 Validation and Application of a New Optimized RP-HPLC-Fluorescent Detection Method for Norfloxacin

Authors: Mahmood Ahmad, Ghulam Murtaza, Sonia Khiljee, Muhammad Asadullah Madni

Abstract:

A new reverse phase-high performance liquid chromatography (RP-HPLC) method with fluorescent detector (FLD) was developed and optimized for Norfloxacin determination in human plasma. Mobile phase specifications, extraction method and excitation and emission wavelengths were varied for optimization. HPLC system contained a reverse phase C18 (5 μm, 4.6 mm×150 mm) column with FLD operated at excitation 330 nm and emission 440 nm. The optimized mobile phase consisted of 14% acetonitrile in buffer solution. The aqueous phase was prepared by mixing 2g of citric acid, 2g sodium acetate and 1 ml of triethylamine in 1 L of Milli-Q water was run at a flow rate of 1.2 mL/min. The standard curve was linear for the range tested (0.156–20 μg/mL) and the coefficient of determination was 0.9978. Aceclofenac sodium was used as internal standard. A detection limit of 0.078 μg/mL was achieved. Run time was set at 10 minutes because retention time of norfloxacin was 0.99 min. which shows the rapidness of this method of analysis. The present assay showed good accuracy, precision and sensitivity for Norfloxacin determination in human plasma with a new internal standard and can be applied pharmacokinetic evaluation of Norfloxacin tablets after oral administration in human.

Keywords: Norfloxacin, Aceclofenac sodium, Methodoptimization, RP-HPLC method, Fluorescent detection, Calibrationcurve.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2104
3 Pharmaceutical Microencapsulation Technology for Development of Controlled Release Drug Delivery systems

Authors: Mahmood Ahmad, Asadullah Madni, Muhammad Usman, Abubakar Munir, Naveed Akhtar, Haji M. Shoaib Khan

Abstract:

This article demonstrated development of controlled release system of an NSAID drug, Diclofenac sodium employing different ratios of Ethyl cellulose. Diclofenac sodium and ethyl cellulose in different proportions were processed by microencapsulation based on phase separation technique to formulate microcapsules. The prepared microcapsules were then compressed into tablets to obtain controlled release oral formulations. In-vitro evaluation was performed by dissolution test of each preparation was conducted in 900 ml of phosphate buffer solution of pH 7.2 maintained at 37 ± 0.5 °C and stirred at 50 rpm. At predetermined time intervals (0, 0.5, 1.0, 1.5, 2, 3, 4, 6, 8, 10, 12, 16, 20 and 24 hrs). The drug concentration in the collected samples was determined by UV spectrophotometer at 276 nm. The physical characteristics of diclofenac sodium microcapsules were according to accepted range. These were off-white, free flowing and spherical in shape. The release profile of diclofenac sodium from microcapsules was found to be directly proportional to the proportion of ethylcellulose and coat thickness. The in-vitro release pattern showed that with ratio of 1:1 and 1:2 (drug: polymer), the percentage release of drug at first hour was 16.91 and 11.52 %, respectively as compared to 1:3 which is only 6.87 % with in this time. The release mechanism followed higuchi model for its release pattern. Tablet Formulation (F2) of present study was found comparable in release profile the marketed brand Phlogin-SR, microcapsules showed an extended release beyond 24 h. Further, a good correlation was found between drug release and proportion of ethylcellulose in the microcapsules. Microencapsulation based on coacervation found as good technique to control release of diclofenac sodium for making the controlled release formulations.

Keywords: Diclofenac sodium, Microencapsulationtechnology, Ethylcellulose, In-Vitro Release Profile

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3160
2 New Simultaneous High Performance Liquid Chromatographic Method for Determination of NSAIDs and Opioid Analgesics in Advanced Drug Delivery Systems and Human Plasma

Authors: Asad Ullah Madni, Mahmood Ahmad, Naveed Akhtar, Muhammad Usman

Abstract:

A new and cost effective RP-HPLC method was developed and validated for simultaneous analysis of non steroidal anti inflammatory dugs Diclofenac sodium (DFS), Flurbiprofen (FLP) and an opioid analgesic Tramadol (TMD) in advanced drug delivery systems (Liposome and Microcapsules), marketed brands and human plasma. Isocratic system was employed for the flow of mobile phase consisting of 10 mM sodium dihydrogen phosphate buffer and acetonitrile in molar ratio of 67: 33 with adjusted pH of 3.2. The stationary phase was hypersil ODS column (C18, 250×4.6 mm i.d., 5 μm) with controlled temperature of 30 C°. DFS in liposomes, microcapsules and marketed drug products was determined in range of 99.76-99.84%. FLP and TMD in microcapsules and brands formulation were 99.78 - 99.94 % and 99.80 - 99.82 %, respectively. Single step liquid-liquid extraction procedure using combination of acetonitrile and trichloroacetic acid (TCA) as protein precipitating agent was employed. The detection limits (at S/N ratio 3) of quality control solutions and plasma samples were 10, 20, and 20 ng/ml for DFS, FLP and TMD, respectively. The Assay was acceptable in linear dynamic range. All other validation parameters were found in limits of FDA and ICH method validation guidelines. The proposed method is sensitive, accurate and precise and could be applicable for routine analysis in pharmaceutical industry as well as in human plasma samples for bioequivalence and pharmacokinetics studies.

Keywords: Diclofenac Sodium, Flurbiprofen, Tramadol, HPLCUV detection, Validation.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1858
1 Modeling of a UAV Longitudinal Dynamics through System Identification Technique

Authors: Asadullah I. Qazi, Mansoor Ahsan, Zahir Ashraf, Uzair Ahmad

Abstract:

System identification of an Unmanned Aerial Vehicle (UAV), to acquire its mathematical model, is a significant step in the process of aircraft flight automation. The need for reliable mathematical model is an established requirement for autopilot design, flight simulator development, aircraft performance appraisal, analysis of aircraft modifications, preflight testing of prototype aircraft and investigation of fatigue life and stress distribution etc.  This research is aimed at system identification of a fixed wing UAV by means of specifically designed flight experiment. The purposely designed flight maneuvers were performed on the UAV and aircraft states were recorded during these flights. Acquired data were preprocessed for noise filtering and bias removal followed by parameter estimation of longitudinal dynamics transfer functions using MATLAB system identification toolbox. Black box identification based transfer function models, in response to elevator and throttle inputs, were estimated using least square error   technique. The identification results show a high confidence level and goodness of fit between the estimated model and actual aircraft response.

Keywords: Black box modeling, fixed wing aircraft, least square error, longitudinal dynamics, system identification.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1137