Search results for: Absorbance
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 33

Search results for: Absorbance

3 Infrared Lightbox and iPhone App for Improving Detection Limit of Phosphate Detecting Dip Strips

Authors: H. Heidari-Bafroui, B. Ribeiro, A. Charbaji, C. Anagnostopoulos, M. Faghri

Abstract:

In this paper, we report the development of a portable and inexpensive infrared lightbox for improving the detection limits of paper-based phosphate devices. Commercial paper-based devices utilize the molybdenum blue protocol to detect phosphate in the environment. Although these devices are easy to use and have a long shelf life, their main deficiency is their low sensitivity based on the qualitative results obtained via a color chart. To improve the results, we constructed a compact infrared lightbox that communicates wirelessly with a smartphone. The system measures the absorbance of radiation for the molybdenum blue reaction in the infrared region of the spectrum. It consists of a lightbox illuminated by four infrared light-emitting diodes, an infrared digital camera, a Raspberry Pi microcontroller, a mini-router, and an iPhone to control the microcontroller. An iPhone application was also developed to analyze images captured by the infrared camera in order to quantify phosphate concentrations. Additionally, the app connects to an online data center to present a highly scalable worldwide system for tracking and analyzing field measurements. In this study, the detection limits for two popular commercial devices were improved by a factor of 4 for the Quantofix devices (from 1.3 ppm using visible light to 300 ppb using infrared illumination) and a factor of 6 for the Indigo units (from 9.2 ppm to 1.4 ppm) with repeatability of less than or equal to 1.2% relative standard deviation (RSD). The system also provides more granular concentration information compared to the discrete color chart used by commercial devices and it can be easily adapted for use in other applications.

Keywords: Infrared lightbox, paper-based device, phosphate detection, smartphone colorimetric analyzer.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 651
2 Red Diode Laser in the Treatment of Epidermal Diseases in PDT

Authors: Farhad H. Mustafa, Mohamad S. Jaafar , Asaad H. Ismail, Ahamad F. Omar, Zahra A. Timimi, Hend A. A. Houssein

Abstract:

The process of laser absorption in the skin during laser irradiation was a critical point in medical application treatments. Delivery the correct amount of laser light is a critical element in photodynamic therapy (PDT). More amounts of laser light able to affect tissues in the skin and small amount not able to enhance PDT procedure in skin. The knowledge of the skin tone laser dependent distribution of 635 nm radiation and its penetration depth in skin is a very important precondition for the investigation of advantage laser induced effect in (PDT) in epidermis diseases (psoriasis). The aim of this work was to estimate an optimum effect of diode laser (635 nm) on the treatment of epidermis diseases in different color skin. Furthermore, it is to improve safety of laser in PDT in epidermis diseases treatment. Advanced system analytical program (ASAP) which is a new approach in investigating the PDT, dependent on optical properties of different skin color was used in present work. A two layered Realistic Skin Model (RSM); stratum corneum and epidermal with red laser (635 nm, 10 mW) were used for irradiative transfer to study fluence and absorbance in different penetration for various human skin colors. Several skin tones very fair, fair, light, medium and dark are used to irradiative transfer. This investigation involved the principles of laser tissue interaction when the skin optically injected by a red laser diode. The results demonstrated that the power characteristic of a laser diode (635 nm) can affect the treatment of epidermal disease in various color skins. Power absorption of the various human skins were recorded and analyzed in order to find the influence of the melanin in PDT treatment in epidermal disease. A two layered RSM show that the change in penetration depth in epidermal layer of the color skin has a larger effect on the distribution of absorbed laser in the skin; this is due to the variation of the melanin concentration for each color.

Keywords: Photodynamic therapy, Realistic skin model, Laser, Light penetration, simulation, Optical properties of skin, Melanin.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2376
1 Quantitative and Fourier Transform Infrared Analysis of Saponins from Three Kenyan Ruellia Species: Ruellia prostrata, Ruellia lineari-bracteolata and Ruellia bignoniiflora

Authors: Christine O. Wangia, Jennifer A. Orwa, Francis W. Muregi, Patrick G. Kareru, Kipyegon Cheruiyot, Eric Guantai

Abstract:

Ruellia (syn. Dipteracanthus) species are wild perennial creepers belonging to the Acanthaceae family. These species are reported to possess anti-inflammatory, analgesic, antioxidant, gastroprotective, anticancer, and immuno-stimulant properties. Phytochemical screening of both aqueous and methanolic extracts of Ruellia species revealed the presence of saponins. Saponins have been reported to possess anti-inflammatory, antioxidant, immuno-stimulant, antihepatotoxic, antibacterial, anticarcinogenic, and antiulcerogenic activities. The objective of this study was to quantify and analyze the Fourier transform infrared (FTIR) spectra of saponins in crude extracts of three Kenyan Ruellia species namely Ruellia prostrata (RPM), Ruellia lineari-bracteolata (RLB) and Ruellia bignoniiflora (RBK). Sequential organic extraction of the ground whole plant material was done using petroleum ether (PE), chloroform, ethyl acetate (EtOAc), and absolute methanol by cold maceration, while aqueous extraction was by hot maceration. The plant powders and extracts were mixed with spectroscopic grade KBr and compressed into a pellet. The infrared spectra were recorded using a Shimadzu FTIR spectrophotometer of 8000 series in the range of 3500 cm-1 - 500 cm-1. Quantitative determination of the saponins was done using standard procedures. Quantitative analysis of saponins showed that RPM had the highest quantity of crude saponins (2.05% ± 0.03), followed by RLB (1.4% ± 0.15) and RBK (1.25% ± 0.11), respectively. FTIR spectra revealed the spectral peaks characteristic for saponins in RPM, RLB, and RBK plant powders, aqueous and methanol extracts; O-H absorption (3265 - 3393 cm-1), C-H absorption ranging from 2851 to 2924 cm-1, C=C absorbance (1628 - 1655 cm-1), oligosaccharide linkage (C-O-C) absorption due to sapogenins (1036 - 1042 cm-1). The crude saponins from RPM, RLB and RBK showed similar peaks to their respective extracts. The presence of the saponins in extracts of RPM, RLB and RBK may be responsible for some of the biological activities reported in the Ruellia species.1

Keywords: Ruellia bignoniiflora, Ruellia lineari-bracteolata, Ruellia prostrata, Saponins.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1191